360-382 Snediker Avenue, Brooklyn
Brooklyn • Block 03782 • Lot 0130 • Zip: 11207
Condition
What the city currently has open against this building, counted from its own records.
Address
Land use and zoning
Building
Latest assessment
Neighborhood
The area this lot falls inside, and the commute Hoodkit measures from it.
Getting around
Estimated 3 days ago- Downtown Brooklyn 45 min 13 walking, 32 riding
- Fulton Street 52 min 13 walking, 39 riding
- Union Square 58 min 13 walking, 45 riding
- Grand Central 62 min 13 walking, 49 riding
- Penn Station 62 min 13 walking, 49 riding
- Times Square 63 min 13 walking, 50 riding
Around this address
Transit and places within 0.5 miles of the lot.
Getting out
Subway
Railroad
Bus
Citi Bike
Places nearby
Activity
Sales, filings, permits and violations from every dataset, in one order.
2026
-
HPD violation Jul 23, 2026
Class B
§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIAL AT CEILING A...
-
HPD violation Jul 23, 2026
Class C
§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING AT PUBLIC HALL, 1st...
-
HPD violation Jul 23, 2026
Class A
§ 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE CEILING AND WEST WALL AT...
-
HPD violation Jul 16, 2026
Class C
§ 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CL...
-
HPD violation Jun 17, 2026
Class B
§ 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10 SQ.FT AT CEILING IN...
-
HPD violation May 5, 2026
Class C
§ 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CL...
2025
-
CLASS - 2
FAILURE TO COMPLY WITH COMMISSIONER'S ORDER CONTAINED IN SUMMONS #39083642L ISSUED ON 04/12/2023, AND FAILURE TO FILE...
2023
-
DOB violation Dec 1, 2023
EGRADE-FAILURE TO POST ENERGY GRADE/SCORE NONE
FAILURE TO DISPLAY ENERGY EFFICIENCY SCORE AND ENERGY EFFICIENCY GRADE AS PER ADCODE SEC. 28-309.12.3
-
CLASS - 2
THIS IS A MODULAR BOILER BANK OF 6,#3BOILER HAS A PLUG ON THE RELIEF VALVE & MUST BE REMOVED,BACKFLOW PREVENTOR CANNO...
2022
-
CLASS - 1
OUT OF SERVICE. UPON INSPECTION, THE DEVICE IS FOUND TO BE OUT-OF-SERVICE REMEDY: RESTORE TO SERVICE IMMEDIATELY AND,...
2021
-
DOB violation Jul 21, 2021
AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
-
DOB violation Jul 21, 2021
AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
-
DOB violation Apr 29, 2021
EGRADE-FAILURE TO POST ENERGY GRADE/SCORE NONE
FAILURE TO DISPLAY ENERGY EFFICIENCY SCORE AND ENERGY EFFICIENCY GRADE AS PER ADCODE SEC. 28-309.12.3
-
DOB violation Apr 28, 2021
AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
-
CLASS - 1
1) NO DOOR LOCK MONITORING INSTALLED IN THIS CONTROLLER AS MANDATED BY 3.10.12 OF APPENDIX K3 OF THE 2014 NYCBC. THIS...
-
CLASS - 1
1) NO DOOR LOCK MONITORING INSTALLED IN THIS CONTROLLER AS MANDATED BY 3.10.12 OF APPENDIX K3 OF THE 2014 NYCBC. THIS...
-
DOB violation Mar 17, 2021
AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
2020
2018
2016
-
Alteration Type III
REPLACEMENT OF EXISTING TELECOMMUNICATION ANTENNAS AND RRH UNITS ON ROOF. RETROFIT EXISTING CABINET IN THE EXISTING E...
2014
-
Alteration Type III
INSTALLATION OF ADDITIONAL TELECOMMUNICATIONS CABINET ON EXISTING DUNNAGE ON ROOF INSTALLATION OF RELATED ANTENNAS ON...
2011
-
Alteration Type III
INSTALLING 2X2 TELECOMMUNICATIONS EQUIPMENT CABINET ON EXISTING STEEL PLATFORM ON ROOF IN CONFORMANCE WITH TPPN#5/98 ...
2008
-
Alteration Type I
CONSTRUCT ADDITIONAL MEDICAL OFFICES AT THE CELLAR AND FIRST FLOOR AND PROVIDE NEW ELEVATOR FILED IN CONJUNCTIO N WIT...
-
Alteration Type III
INSTALLATION OF ADDITIONAL TELECOMMUNICATION CABINETS AND ATTENNAS ON ROOF. INITIAL INSTATION APPROVED UNDERAPPLICATI...
2007
2005
-
Alteration Type II
INSTALL UNCODED INTERIOR FIRE ALARM SYSTEM IN CELLAR AND FIRST FLOOR MEDICAL OFFICES. FILED IN CONJUNCTION WITH NB #3...
The most recent 6 events from each dataset, so no one source takes the axis. Each tab holds the full record.
Property Contacts
Contact information aggregated from multiple government sources
Registration Contracts
Contact information from multiple dwelling registrations
Building Permits
Owner information from Department of Buildings filings
Recent Building Permits
Owner information from recent DOB NOW filings
Deed Records
Parties from ACRIS deed and mortgage records
Property Records
Owner information from assessment and PLUTO records