ECB violations

Dumont Avenue, Brooklyn • Block 03785 • Lot 0015

15 records

Environmental Control Board violations, which carry a hearing and a penalty.

Issued Violation Status Severity Description Penalty Balance due Hearing
Aug 9, 2024 39531238X RESOLVE CLASS - 2 OBSERVED SIDEWALK SHED INSTALLED AT EXP#1&2 NOT AS PER CODE, NO MIRRORS AT CORNER OF EXP#1&#2 WHERE PEDESTRIAN'S VIEW... $2,400 $0 May 23, 2025
Sep 29, 2020 39029504X RESOLVE CLASS - 2 BODY DRAIN DISCHARGE PIPES MISSING ON SAFETY VALVES; CORRECT VIOLATION AND SUBMIT THE CERTIFICATE OF CORRECTION $625 $0 Oct 5, 2020
Sep 29, 2020 39029503Y RESOLVE CLASS - 2 FRONT CONDENSATE TANK IS LEAKING-HW STORAGE TANK SAFETY VALVE IS DEFECTIVE-VACUUM TANK COVER GASKET IS DEFECTIVE-GAS ... $625 $0 Oct 5, 2020
Sep 29, 2020 39029505H RESOLVE CLASS - 2 BODY DRAIN DISCHARGE PIPES MISSING ON SAFETY VALVES; CORRECT VIOLATION AND SUBMIT THE CERTIFICATE OF CORRECTION $625 $0 Oct 5, 2020
May 15, 2017 32088447Y RESOLVE CLASS - 2 18A,50,50A,50B,50C,50D,50E,50F. 50-LWCO RT SIDE LEAKING; 50A-KING STEAM VALVE PACKING LEAKING ABOVE BOILER; 50B-CHECK... $0 $0 Jul 17, 2017
May 15, 2017 32088448X RESOLVE CLASS - 2 50,50A,50B,50C,50D,50E. 50-LOWER FRONT MOTORIZED VALVE LEAKING; 50A SEWER PIPE LEAK THROUGH BOILER ROOM CEILING RT OF... $0 $0 Jul 17, 2017
May 15, 2017 32088446M RESOLVE CLASS - 2 50,50A,50B,50C,50D,50E,50F,50G,50H,32A. 50-REAR BOILER INSULATION JACKET DEFECTIVE; 50A-REAR TUBE DOOR BOLTS DEFECTIV... $0 $0 Jul 17, 2017
Jul 12, 2016 32077140X RESOLVE CLASS - 2 50A,50B. FEDERAL F.T.S.H. LP STEAM BLR FST 400,OIL-FD; 1992; 50A-EVIDENCE OF EXCESSIVE SLUDGE AND SCALE ACCUMULIATION... $0 $0 Sep 12, 2016
Jul 12, 2016 32077141H RESOLVE CLASS - 2 50A,50B. FEDERAL FTSH LP STEAM, BLR, FST 400 OIL-FD 1992; 50A-EVIDENCE OF EXCESSIVE SLUDGE AND SCALE ACCUMULATION IN ... $0 $0 Sep 12, 2016
Jul 12, 2016 32077139Z RESOLVE CLASS - 1 59A,51. FEDERAL F.T.S.H. LP STEAM BLR FST 400; OIL-FIRED; 50A-REFERENCED BOILER SUSTAINED SIGNIFCANT THERMAL DAMAGE T... $0 $0 Sep 12, 2016
Mar 25, 2008 38183410Y RESOLVE Non-Hazardous 17H11.17D06.10H11.66O02.14H11. 17HD REPLACE & SECURE WHERE NEEDED 10H REPLACE CAR DOOR GIBS 66O CLEAN PIT 14H REPLACE... $0 $0 May 19, 2008
May 26, 2006 34549939M RESOLVE Non-Hazardous FAILURE TO SUBMIT A FIFTH ROUND TECHNICAL REPORT IN COMPLIANCE W/ CODEPROVISIONS:PERIODIC INSPECTION OF EXTERIOR WALL... $0 $0 Jul 17, 2006
May 26, 2006 34549940J RESOLVE Non-Hazardous FAILURE TO SUBMIT A FIFTH ROUND TECHNICAL REPORT IN COMPLIANCE W/ CODEPROVISIONS:PERIODIC INSPECTION OF EXTERIOR WALL... $0 $0 Jul 17, 2006
Dec 9, 2005 34548924P RESOLVE Non-Hazardous FAILURE TO SUBMIT A FIFTH ROUND TECHNICAL REPORT IN COMPLIANCE WITH CODE PROVISIONS: PERIODIC INSPECTION OF EXTERIOR ... $0 $0 Jan 9, 2006
Dec 9, 2005 34548923N RESOLVE Non-Hazardous FAILURE TO SUBMIT A FIFTH ROUND TECHNICAL REPORT IN COMPLIANCE WITH CODE PROVISIONS: PERIODIC INSPECTION OF EXTERIOR ... $0 $0 Jan 9, 2006