Maintenance code violations
676 Miller Avenue, Brooklyn • Block 03827 • Lot 0051
652 records
HPD grades a violation A for non-hazardous through C for immediately hazardous.
| Issued | Class | Status | Violation | Apartment | Correct by |
|---|---|---|---|---|---|
| Jan 18, 2017 | B | VIOLATION CLOSED | § 27-2005 ADM CODE REPLACE WITH NEW THE MISSING LIDS AT GARBAGE CONTAINERS,BUILDING FRONT ENTRANCE COURT | — | Feb 22, 2017 |
| Jan 18, 2017 | C | VIOLATION CLOSED | § 27-2018 ADM CODE ABATE THE NUISANCE CONSISTING OF RODENTS RAT INFESTATION AT ENTIRE BUILDING | — | Jan 26, 2017 |
| Jan 18, 2017 | B | VIOLATION CLOSED | § 27-2005, 2007 ADM CODE REMOVE ALL ENCUMBRANCES CONSISTING OF HOUSEHOLD ITEMS AT PUBLIC HALL, 1st STORY | — | Feb 22, 2017 |
| Jan 18, 2017 | B | VIOLATION CLOSED | § 27-2010, 2011, 2012 ADM CODE REMOVE THE ACCUMULATION OF REFUSE AND/OR RUBBISH AND MAINTAIN IN A CLEAN CONDITION THE... | — | Feb 22, 2017 |
| Jan 18, 2017 | B | VIOLATION CLOSED | § 27-2010, 2011, 2012 ADM CODE REMOVE THE ACCUMULATION OF REFUSE AND/OR RUBBISH AND MAINTAIN IN A CLEAN CONDITION THE... | — | Feb 22, 2017 |
| Jan 18, 2017 | B | VIOLATION CLOSED | § 27-2010, 2011, 2012 ADM CODE REMOVE THE ACCUMULATION OF REFUSE AND/OR RUBBISH AND MAINTAIN IN A CLEAN CONDITION THE... | — | Feb 22, 2017 |
| Jan 18, 2017 | C | VIOLATION CLOSED | § 27-2005 ADM CODE REPLACE WITH NEW THE MISSING BALUSTER AT 9TH WOOD TREAD BOTTOM UP FROM INTERMEDIATE LANDING AT PUB... | — | Jan 26, 2017 |
| Jan 18, 2017 | B | VIOLATION CLOSED | § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE WOOD TREAD 9TH BOTTOM UP FROM INTERMEDIATE LANDING AT PUB... | — | Feb 22, 2017 |
| Jan 18, 2017 | B | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FLASHING CEMENT / TARS AT WEST PARAP... | — | Feb 22, 2017 |
| Jan 18, 2017 | B | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FLASHING CEMENT / TARS AT SOUTH ,WES... | — | Feb 22, 2017 |
| Jan 18, 2017 | B | VIOLATION CLOSED | § 27-2005, 2007 ADM CODE FIRE EGRESS DEFECTIVE. REMOVE OBSTRUCTING BARS OR UNLAWFUL GATES FROM WINDOW TO FIRE ESCAPE ... | 5 | Feb 22, 2017 |
| Jan 18, 2017 | B | VIOLATION CLOSED | § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING IN THE ENTIRE APARTMENT LOCATED A... | 5 | Feb 22, 2017 |
| Jan 18, 2017 | B | VIOLATION CLOSED | § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 5, 3rd STORY, ... | 5 | Feb 22, 2017 |
| Jan 18, 2017 | C | VIOLATION CLOSED | § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE STILE LATCH OF UPPER SASH AT 2ND WINDOW FROM EAST AT SOUT... | 5 | Jan 26, 2017 |
| Jan 18, 2017 | B | VIOLATION CLOSED | § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK AT CEILING IN THE 2nd ROOM FROM NORTH AT EAST LOCATED AT ... | 5 | Feb 22, 2017 |
| Jan 18, 2017 | C | VIOLATION CLOSED | § 27-2005 HMC:TRACE AND REPAIR THE SOURCE AND ABATE THE NUISANCE CONSISTING OF MOLD ... NORTH AND WEST WALLS APPROX. ... | 5 | Jan 26, 2017 |
| Jan 18, 2017 | C | VIOLATION CLOSED | § 27-2005 HMC:TRACE AND REPAIR THE SOURCE AND ABATE THE NUISANCE CONSISTING OF MOLD ... AT CEILING APPROX. 110 SQUARE... | 5 | Jan 26, 2017 |
| Jan 18, 2017 | C | VIOLATION CLOSED | § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE INTERIOR GLASS PANE AT LOWER SASH OF EAST WINDOW IN THE B... | 5 | Jan 26, 2017 |
| Jan 18, 2017 | B | VIOLATION CLOSED | § 27-2005 HMC:TRACE AND REPAIR THE SOURCE AND ABATE THE NUISANCE CONSISTING OF MOLD ... AT CEILING ,SOUTH AND WEST WA... | 5 | Feb 22, 2017 |
| Jan 18, 2017 | B | VIOLATION CLOSED | § 27-2005, 2007 ADM CODE REMOVE ALL ENCUMBRANCES CONSISTING OF HOUSEHOLD ITEMS AT PUBLIC HALL, 1st STORY | — | Feb 22, 2017 |
| Jan 18, 2017 | C | VIOLATION CLOSED | § 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) IN ACCORDANCE WITH THE SPECIFICAT... | 2R | Feb 15, 2017 |
| Jan 18, 2017 | B | VIOLATION CLOSED | § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING IN THE ENTIRE APARTMENT LOCATED A... | 2R | Feb 22, 2017 |
| Jan 18, 2017 | B | VIOLATION CLOSED | § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 2R, 2nd STORY,... | 2R | Feb 22, 2017 |
| Jan 18, 2017 | B | VIOLATION CLOSED | § 27-2005 HMC:TRACE AND REPAIR THE SOURCE AND ABATE THE NUISANCE CONSISTING OF MOLD ... AT CEILING ,SOUTH AND WEST WA... | 2R | Feb 22, 2017 |
| Jan 18, 2017 | C | VIOLATION CLOSED | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE 2nd ROOM FRO... | 2R | Jan 26, 2017 |
| Jan 18, 2017 | C | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE COUNTER BALANCES OF UPPER SASH AT 1ST WINDOW FROM EAST IN ... | 2R | Jan 26, 2017 |
| Jan 18, 2017 | C | VIOLATION CLOSED | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE KITCHEN LOCA... | 2R | Jan 26, 2017 |
| Jan 18, 2017 | B | VIOLATION CLOSED | § 27-2005 HMC:TRACE AND REPAIR THE SOURCE AND ABATE THE NUISANCE CONSISTING OF MOLD ... AT CEILING AND EAST WALL APPR... | 2R | Feb 22, 2017 |
| Jan 13, 2017 | A | VIOLATION CLOSED | § 27-2005 ADM CODE REFIT DOOR AT ENTRANCE AT PUBLIC HALL, 1st STORY | — | Apr 18, 2017 |
| Jan 5, 2017 | B | VIOLATION CLOSED | § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK OVER CEILING AT SKYLIGHT AT PUBLIC HALL, 3rd STORY | — | Feb 9, 2017 |
| Dec 5, 2016 | A | VIOLATION CLOSED | § 27-2014 ADM CODE AND DEPT. RULES AND REGULATIONS. SCRAPE AND REMOVE RUST SCALES AND PAINT WITH 2 COATS OF PAINT 2ND... | — | Mar 10, 2017 |
| Nov 22, 2016 | C | VIOLATION CLOSED | § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF UNCAPPED RISER PIPE IN THE KITCHEN LOCATED AT APT 2... | 2R | Nov 30, 2016 |
| Nov 22, 2016 | C | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE UPPER AND LOWER SASH COUNTER BALANCE AT FIRE ESCAPE WINDOW... | 2R | Nov 30, 2016 |
| Nov 22, 2016 | B | VIOLATION CLOSED | § 27-2046.1, 2046.2 HMC: PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANC... | 2R | Dec 27, 2016 |
| Nov 22, 2016 | B | VIOLATION CLOSED | § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING LOCATED AT APT 2R, 2nd STORY, 1st APARTMENT FROM NORT... | 2R | Dec 27, 2016 |
| Nov 22, 2016 | A | VIOLATION CLOSED | § 27-2005 ADM CODE REPLACE WITH NEW THE MISSING ESCUTCHEON PLATE AT RISER AT CEILING IN THE KITCHEN LOCATED AT APT 2R... | 2R | Feb 25, 2017 |
| Nov 22, 2016 | B | VIOLATION CLOSED | § 27-2005, 2006, 2037 HMC: PROPERLY REPAIR AND ABATE UNSAFE ELECTRIC WIRING CONDITION CONSISTING OF EXPOSED WIRE AT E... | 2R | Dec 27, 2016 |
| Nov 14, 2016 | C | VIOLATION DISMISSED | § 27-2033 ADM CODE POST NOTICE, IN FORM APPROVED BY THE DEPARTMENT, STATING THE NAME AND LOCATION OF THE PERSON DESIG... | — | Nov 22, 2016 |
| Nov 14, 2016 | C | VIOLATION CLOSED | § 27-2033 ADM CODE POST NOTICE, IN FORM APPROVED BY THE DEPARTMENT, STATING THE NAME AND LOCATION OF THE PERSON DESIG... | — | Nov 22, 2016 |
| — | I | VIOLATION DISMISSED | §27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE §27... | — | — |
| Nov 3, 2016 | C | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE PLASTER AT THE CEILING FIRE RETARDAN... | — | Nov 11, 2016 |
| Nov 3, 2016 | B | VIOLATION CLOSED | § 27-2005, 2006, 2037 HMC: PROPERLY REPAIR AND ABATE UNSAFE ELECTRIC WIRING CONDITION CONSISTING OF EXPOSED ELECTRICA... | — | Dec 8, 2016 |
| Nov 3, 2016 | B | VIOLATION CLOSED | § 27-2021 ADM CODE PROVIDE SUFFICIENT, PROPER AND SEPARATE METAL RECEPTACLES FOR THE DEPOSIT OF GARBAGE, RUBBISH AND ... | — | Dec 8, 2016 |
| Nov 3, 2016 | B | VIOLATION CLOSED | § 27-2010, 2011, 2012 ADM CODE REMOVE THE ACCUMULATION OF REFUSE AND/OR RUBBISH AND MAINTAIN IN A CLEAN CONDITION THE... | — | Dec 8, 2016 |
| Nov 3, 2016 | B | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE MAILBOXES AT PUBLIC HALL, 1st STORY | — | Dec 8, 2016 |
| Nov 3, 2016 | C | VIOLATION CLOSED | § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK AT THE CEILING AT THE SKYLIGHT AT PUBLIC HALL STAIRS, 3rd... | — | Nov 11, 2016 |
| Nov 3, 2016 | C | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE PLASTER AT THE CEILING FIRE RETARDAN... | — | Nov 11, 2016 |
| Oct 28, 2016 | A | VIOLATION CLOSED | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT WALLS AND CEILINGS THROUGHOU... | — | Jan 31, 2017 |
| Oct 28, 2016 | A | VIOLATION CLOSED | § 27-2011 ADM CODE CLEANSE TO THE SATISFACTION OF THIS DEPARTMENT THE FLOOR AT PUBLIC HALL STAIRS, 3rd STORY | — | Jan 31, 2017 |
| Oct 28, 2016 | A | VIOLATION CLOSED | § 329, M/D LAW AND DEPT. RULES AND REGS. PROVIDE A COMPLETED CERTIFICATE OF INSPECTION VISITS IN A PROPER FRAME AT OR... | — | Jan 31, 2017 |