ECB violations
233 Jamaica Avenue, Brooklyn • Block 03896 • Lot 0035
44 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Mar 10, 2026 | 39179816Z | RESOLVE | CLASS - 2 | 1) CLEANING OF COMBUSTIBLE MATERIALS IN ELEVATOR PIT. 2) OPEN ELECTRICAL BOX IN PIT. 3) IN-CAR COMMUNICATION INOPERAT... | $0 | $0 | May 20, 2026 |
| Oct 1, 2024 | 37031208L | RESOLVE | CLASS - 1 | FAILURE TO SUBMIT THE REQUIRED PARKING STRUCTURE INITIAL OBSERVATION REPORT FOR AN EXISTING PARKING STRUCTURE OR A PE... | $0 | $0 | Jul 22, 2025 |
| Nov 14, 2023 | 35675358H | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN BUILDING WALL(S) OR APPURTENANCES. AT TIME OF INSPECTION OBSERVED, CRACKS/DAMAGED WINDOW GLASS AT... | $0 | $0 | Jan 24, 2024 |
| Oct 10, 2023 | 35674569N | RESOLVE | CLASS - 1 | UNLAWFUL ACTS. FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER. RESPONDANT FAILED TO COMPLY WITH PREVIOUS VIOLATIONS ... | $0 | $0 | Jun 21, 2024 |
| Jul 11, 2023 | 35671086P | RESOLVE | CLASS - 1 | UNLAWFUL ACT. FAILURE TO COMPLY WITH AN ORDER OF THE COMMISSIONER'S: OWNER/RESPONDENT FAILED TO COMPLY WITH PREVIOUS ... | $0 | $0 | Jun 21, 2024 |
| Apr 13, 2023 | 35671075J | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN BUILDING EXTERIOR WALLS/FACADE AND APPURTENANCES. OBSERVED BRICKS ON WINDOW LEDGE ON 2ND FLOOR CL... | $0 | $0 | Jun 21, 2024 |
| Dec 21, 2022 | 35669516N | RESOLVE | CLASS - 1 | UNLAWFUL ACTS.FAILURE TO COMPLY W/COMMISSIONER ORDER.NOTE:AS PER PREV ECB VIO35664374Y ISSUED 10/18/22&DOB VIO CONTRO... | $0 | $0 | Mar 1, 2023 |
| Dec 21, 2022 | 35669517P | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN EXTERIOR BLDG FACADE&APPURTENANCES.ATOI OBSERVED BROKEN WINDOW GLASS@EXP2W ELEVATION WINDOW 7FL 2... | $625 | $0 | Mar 1, 2023 |
| Oct 18, 2022 | 35664374Y | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN EXTERIOR BLDG FACADE&APPURTENANCES.NOTE:(I)EXP1S ELEVATION OBSERVED BULGING/DISPLACED WINDOWSILL@... | $0 | $0 | May 10, 2023 |
| Aug 25, 2022 | 35664161K | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN EXTERIOR FACADE & APPURTENANCES.AT TIME OF INSPECTION OBSERVED OPEN MORTAR JOINT & CRACKS AT EXP.... | $0 | $0 | Jan 25, 2023 |
| Mar 16, 2020 | 39019782R | RESOLVE | CLASS - 2 | CLEAN PIT., CLEAN TOP OF CAR (OIL LEAK)., PROVIDE CURRENT FIRE EXTINGUISHER TAG., REPAIR UNDER CAR LIGHT., PROVIDE UN... | $312 | $0 | Sep 25, 2020 |
| May 22, 2019 | 35422544X | RESOLVE | CLASS - 3 | WORK WITHOUT A PERMIT. NOTED: AT TIME OF INSPECTION, IT WAS OBSERVED, APARTMENT 6D ERECTED (ILLEGALLY) FULL HEIGHT PA... | $0 | $0 | Jan 23, 2020 |
| May 18, 2018 | 37011491H | RESOLVE | CLASS - 2 | FAILURE TO SUBMIT ACCEPTABLE 8TH ROUND REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WALLS AND APP... | $0 | $0 | Dec 24, 2018 |
| Nov 25, 2017 | 38259852J | RESOLVE | CLASS - 2 | 2X10,25M7,14J1,100J6,59BB15,68M7,57BB15,56Y13,56O2,17M7,70O2,71X11. 2X10 IN CAR PHONE INOPERATIVE.25M7 MISSING BRAILL... | $0 | $0 | Jan 22, 2018 |
| Oct 1, 2017 | 35278854H | RESOLVE | CLASS - 2 | FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER CONTAINED IN SUMMONS/VIO # 35229231K ISSUED ON 03/07/17 & TO FILE A C... | $800 | $0 | Nov 20, 2017 |
| Aug 22, 2017 | 35277129K | RESOLVE | CLASS - 1 | FAILURE TO COMPLY W/COMMISSIONERS ORDER CONTAINED IN SUMMONS/VIOLATION#35229231K ISSUED ON 03/07/17 AND TO FILE A COF... | $2,000 | $0 | Jan 8, 2018 |
| Jul 8, 2017 | 35274770M | RESOLVE | CLASS - 1 | FAILURE TO COMPLY W/THE COMM'S ORDER CONTAINED IN SUMMONS/VIO#35229231K ISSUED ON 3-07-17 & TO FILE A C OF C PURSUANT... | $800 | $0 | Oct 25, 2017 |
| Jun 8, 2017 | 35234186R | RESOLVE | CLASS - 2 | FAILURE TO COMPLY W/THE COMM'S ORDER CONTAINED IN SUMMONS/VIO#35229231K ISSUED ON 03/07/17 & TO FILE A C OF C PURSUAN... | $800 | $0 | Jul 24, 2017 |
| Apr 29, 2017 | 35233098M | RESOLVE | CLASS - 1 | FAILURE TO COMPLY W/THE COMM'S ORDER CONTAINED IN SUMMONS/VIO#35229231K ISSUED ON 3-07-17 & TO FILE A C OF C PURSUANT... | $800 | $0 | Jun 19, 2017 |
| Mar 7, 2017 | 35229231K | RESOLVE | CLASS - 1 | WORK WITHOUT A PERMIT.NOTE:AT APARTMENT 1D,WALL ERECTED IN LIVING ROOMAREA TO CEILING WITH DOOR SEPERATION KITCHEN AR... | $400 | $0 | Apr 24, 2017 |
| Sep 3, 2010 | 38213065R | RESOLVE | CLASS - 1 | 02X10 08V01 05J01 42D06 42H11 42G11 38I11 56Y13 56Y02 39Y02 39O02 34O02. RESPONDENT FILED A C/C ON JUNE 29, 2010 FOR ... | $4,800 | $0 | Jul 27, 2011 |
| Sep 3, 2010 | 38213064P | RESOLVE | CLASS - 2 | 02X10,08V01,05J01,42D06,42H11,42G11,38I11,56Y13,56Y02,39Y02,39O02,34O02 FAILURE TO COMPLY W/THE COMM'S ORDER TO FILE ... | $800 | $0 | Jul 27, 2011 |
| Sep 3, 2010 | 38213051X | RESOLVE | CLASS - 2 | *02X10 *08V01 *05J10 *42D06 *42H11 *42G11 *38I11 *56Y13 *56Y02 *39Y02 *39O02 *34O02 03I10 03M07 17H11 17D06 41W06 61G... | $250 | $0 | Feb 8, 2011 |
| Jul 21, 2009 | 38204859Y | RESOLVE | CLASS - 2 | 02X10.17H11.39O2.42H11 WORN CONTACTS ON CONTROLLER 42D6 PROPERLY SECURE DOOR TIMER AND WIRES ON CONTROLLER 64M7 CONTR... | $250 | $0 | Mar 15, 2010 |
| Feb 4, 2009 | 32065630K | RESOLVE | CLASS - 3 | 301.1,16,40,42,50,50A,B354,50B,50C.50-CHIMNEY CLEAN OUT DOOR BROKEN.50A-SMOKE ALARM DEFECTED.50B-BACKFLOW LEAKING.50C... | $100 | $0 | Aug 17, 2009 |
| Oct 9, 2008 | 38192175H | RESOLVE | CLASS - 2 | 40P16.02X10.10H11.17H11.03D06.97C10.70O02.34O02.39O02.39Y02.38I11.05D06.16R10.16R10 GAP BETWEEN HOISTWAY DOOR & STRIK... | $500 | $0 | Dec 1, 2008 |
| Jun 24, 2008 | 38186045Z | RESOLVE | Non-Hazardous | 02L10.05J01.10D06.21J01.03X10.40I10.38Y02.55Y13.66O02.17H11. 05 ADJUSTGAP ON CAB DOOR UPPER DOOR HANGER & CONNECTIONS... | $0 | $0 | Aug 18, 2008 |
| Sep 7, 2004 | 38148962Z | RESOLVE | Non-Hazardous | 12Q03/03A07/28L10/23L10/38O02/66O02/39P16. 03-A, REPLACE HAND RAILS PROVIDE CAPACITY PLATE. 28-L, ADJUST FOR PROPER O... | $0 | $0 | Oct 25, 2004 |
| Feb 2, 2004 | 38145052X | RESOLVE | Non-Hazardous | 83X10/ (83) REPAIR AND RESTORE ELEVATOR TO SERVICE SO THAT A FULL INSPECTION CAN BE MADE BY THIS DEPT. | $0 | $0 | Mar 22, 2004 |
| Apr 30, 2003 | 34400383K | RESOLVE | Hazardous | FAILURE TO MAINTAIN EXTERIOR BUILDING WALL. NOTED: TWO UNSECURED BRICKS ON 2ND FL. WINDOW SILL IN DANGER OF FALLING O... | $800 | $0 | Aug 21, 2003 |
| Oct 24, 2001 | 34258340X | RESOLVE | Hazardous | FAILURE TO MAINTAIN EXTERRIOR BUILDING WALL. NOTED: 1" THICK BY 3'0"X2'0" (APPROX.) STONE DISPLACEC + LEANING APPROX.... | $2,500 | $0 | Jan 28, 2002 |
| Jan 30, 2001 | 38111307N | RESOLVE | Hazardous | 15B11. 15B-HOISTWAY DOORS NOT SELF CLOSING-MISSING ROLLERS. | $0 | $0 | May 14, 2001 |
| Oct 16, 2000 | 38107770N | RESOLVE | Hazardous | 06M12 09M12 07X11 07E11 73O02 29I12 62M07 75U05 52J01 74L12 74 COVTEN WEIGHT SPRINGS PAMRRGBN | $2,500 | $0 | Dec 4, 2000 |
| Oct 1, 2000 | 38106843K | RESOLVE | Hazardous | 15I11 15B11 17I11 73X11 FOR RESTORE TO SERVICE CALL 212-312-8731.15I-4 FLOOR HOISTWAY DOOR-REPAIR 15B-HOISEWAY DOORS ... | $500 | $0 | May 14, 2001 |
| Aug 11, 2000 | 38107213K | RESOLVE | Non-Hazardous | 07X11/07E11/15L11/73M07/73002/29I12/62M07/75U05/50#1/52J01/50#11 - 07X11 DOOR OPEN BUTTON, 07E11 SAFETY EDGE DRAGGING... | $2,500 | $0 | Sep 25, 2000 |
| Jul 17, 2000 | 38098135M | RESOLVE | Non-Hazardous | 46H12,37B07,03M07,14M07,50J11,35I07,74B11,75R05.37-RELAYS LOOSE ON CONROLLING.03-NO FAN IN CAR.50J-VIBRATION FROM MAC... | $2,500 | $0 | Sep 7, 2000 |
| Jan 6, 2000 | 34223535X | RESOLVE | Non-Hazardous | FAILURE TO FILE A REPORT OF COMPLINACE WITH LOCAL LAW 16/84 CERTIFYING TO THE INSTALLATION OF REQUIRED FIRE PROTECTIO... | $2,500 | $0 | Feb 28, 2000 |
| May 10, 1999 | 38086244N | RESOLVE | Non-Hazardous | 75U16-TAG OR FILE FOR TEST. | $2,500 | $0 | Jun 28, 1999 |
| Jun 30, 1998 | 38075604Y | RESOLVE | Non-Hazardous | 73X,75U, 73-RESTORE TO SERVICE FOR PROPER INSPECTION. | $2,500 | $0 | Aug 17, 1998 |
| Jun 22, 1998 | 38076238H | RESOLVE | Non-Hazardous | 75M5,3O2,3E11,7I12,15B11,16H12,17I12,18Q3,23U16,25Q3,28H12,37D6,39H8, 46M7,46I12,50Q3,52Q3,52B1,74M7. 15-MUST BE SELF... | $2,500 | $0 | Aug 10, 1998 |
| Dec 8, 1997 | 38067127K | RESOLVE | Non-Hazardous | 73X7. RESTORE TO SERVICE SO THAT A FULL INSPECTION CAN BE MADE BY THIS DEPT. | $2,500 | $0 | Jan 26, 1998 |
| Oct 23, 1993 | 38038926Y | RESOLVE | Non-Hazardous | 73X | $0 | $0 | Dec 27, 1993 |
| Jan 23, 1993 | 38030317M | RESOLVE | Non-Hazardous | 14M 22D 21 L 57O | $200 | $0 | Jun 14, 1993 |
| May 5, 1992 | 38025290P | RESOLVE | Non-Hazardous | 08V,14I,22D,35P,57O, (35) UNABLE TO GAIN ACCESS TO MOTOR ROOM TO COMPLETE INSPECTION | $1,000 | $0 | Jul 27, 1992 |