ECB violations
114 Arlington Avenue, Brooklyn • Block 03934 • Lot 0022
22 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Jun 29, 2026 | 39555938N | ACTIVE | CLASS - 1 | AT THE TIME OF INSPECTION OF A 4-STORY NEW BUILDING, A PIPE SCAFFOLD WAS OBSERVED AT EXP# 1-4 EXCEEDING THE HEIGHT 41... | $5,000 | $5,000 | Sep 2, 2026 |
| Oct 17, 2025 | 39546104M | RESOLVE | CLASS - 1 | OBSERVATION: NO HANDRAILS FOR STAIRS @ BASEMENT & 2NDFLOOR, STAIRS W/O INFILLS. GUARDRAILS INADEQUATE THROUGHOUT SITE... | $10,000 | $10,000 | Oct 15, 2026 |
| Oct 16, 2025 | 39546097N | RESOLVE | CLASS - 1 | OBSERVATION: GC FAILED TO FOLLOW PRECAUTIONS FOR WORKING AROUND POWERLINES LOCATED @ REAR YARD CLOSE PROXIMATE TO SCA... | $0 | $0 | Jul 28, 2026 |
| Oct 16, 2025 | 39546098P | RESOLVE | CLASS - 1 | OBSERVATION: COLD FORM STEEL UPON MY REQUEST FOR SPECIAL INSPECTION REPORT NONE WAS PROVIDED. PSWO FOR FAILURE TO PRO... | $2,500 | $2,500 | Jul 28, 2026 |
| Oct 16, 2025 | 39546142N | RESOLVE | CLASS - 1 | FAILURE TO SAFEGUARD THE PUBLIC AND PROPERTY AFFECTED BY CONSTRUCTION OPERATIONS. OBSERVATION: NO HANDRAILS FOR STAIR... | $10,000 | $10,000 | Nov 9, 2026 |
| Oct 16, 2025 | 39546063P | RESOLVE | CLASS - 2 | OBSERVATION: ACTIVE JOBSITE, OPERATIONS ON SCAFFOLDS, STORAGE OF CMU BLOCKS & DEBRIS, EQUIPMENT & MATERIALS ON UNPOUR... | $2,500 | $2,500 | Jul 28, 2026 |
| Oct 16, 2025 | 39546091M | RESOLVE | CLASS - 1 | OBSERVATION: COLD FORM STEEL THROUGHT SITE UPON MY REVIEW OF DRAWINGS COLD FORM MISSING LIGHT GAUGE METAL C-JOIST AND... | $2,500 | $2,500 | Jul 28, 2026 |
| Sep 20, 2025 | 39545133R | ACTIVE | CLASS - 2 | 3314.01. OBSERVED SUPPORTED SCAFFOLD AT ALL EXPOSURE NOT ERECTED AND OR MAINTAINED AS PER CODE REQUIREMENTS. SCAFFOLD... | $2,500 | $2,500 | Nov 26, 2025 |
| Jul 2, 2025 | 39541915N | RESOLVE | CLASS - 2 | AT TIME OF INSPECTION, I OBSERVED 1 TREE AT EXPOSURE #1 WAS NOT PROTECTED AS PER CODE SECTION BC 3309.11. ? PROTECT T... | $0 | $0 | Sep 10, 2025 |
| Apr 22, 2025 | 39539381P | RESOLVE | CLASS - 2 | AT THE OF INSPECTION ON A NON ACTIVE JOB SITE, UPON MY RESEARCH THROUGH DOB NOW SYSTEM I OBSERVED THAT FENCE PERMIT #... | $0 | $0 | Jul 2, 2025 |
| May 21, 2019 | 35421064M | RESOLVE | CLASS - 2 | FAILURE TO POST OR PROPERTY POST PERMIT FOR WORK AT PREMISES(FENCE PERMIT). AT TIME OF INSPECTION ON DEMO-MONITORING ... | $0 | $0 | Sep 9, 2019 |
| May 21, 2019 | 35421066X | RESOLVE | CLASS - 1 | FAILURE TO PROVIDE REQUIRED NOTIFICATION PRIOR TO THE COMMENCEMENT OF DEMOLITION. AT TIME OF INSPECTION OBSERVED GARA... | $2,500 | $0 | Mar 5, 2020 |
| May 21, 2019 | 35421065Y | RESOLVE | CLASS - 2 | PROJECT INFORMATION PANEL NOT PROVIDED OR NOT IN COMPLIANCE W/SECTION.AT TIME OF DEMO-MONITORING INSPECTION OBSERVED ... | $0 | $0 | Sep 9, 2019 |
| May 21, 2019 | 35421062Z | RESOLVE | CLASS - 1 | FAILURE TO PROVIDE REQUIRED NOTIFICATION PRIOR TO THE COMMENCEMENT OF DEMOLITION. AT TIME OF INSPECTION OBSERVED 2 ST... | $2,500 | $0 | Mar 5, 2020 |
| May 21, 2019 | 35421063K | RESOLVE | CLASS - 2 | JOBSITE FENCE NOT CONSTRUCTED OR MAINTAINED PURSUANT TO SUBSECTION.(NOVIEWING PANELS). AT TIME OF INSPECTION ON DEMO-... | $0 | $0 | Sep 9, 2019 |
| Jul 20, 2010 | 34854059P | RESOLVE | CLASS - 2 | SEC. 28-105.1 WORK W/O PERMIT. NOTED: AT FRONT OF THE PREMISES WOODEN STRUCTURE ERECTED APPRX 10FT X 10FT WITH GLASS ... | $6,000 | $0 | Sep 13, 2010 |
| Aug 30, 1999 | 34224909X | RESOLVE | Hazardous | OCCUPANCY CONTRARY TO THAT ALLOWED BY BLDG DEPT RECORDS ILLEGLA OCCUPANCY NOTED GARAGE CONVERTED TO CAR REPAIR SHOP N... | $2,500 | $0 | Oct 18, 1999 |
| Aug 30, 1999 | 34224908Y | RESOLVE | Hazardous | XORK WITHOUT A PERMIT. WORK NOTED:AT REAR OF PREMISES 1STORY ADDITION 35'X18'X10' CONSTRUCTED. NOTE: EXTENSION IS WOO... | $2,500 | $0 | Oct 18, 1999 |
| Aug 26, 1999 | 34221230X | RESOLVE | Non-Hazardous | ILLEGAL USE IN A RESIDENTIAL DISTRICT. THE ILLEGAL USE: AUTO BODY RE- PAIR & STORAGE OF FIVE UNREGISTER VEHICLES AND ... | $2,500 | $0 | Oct 18, 1999 |
| Aug 21, 1999 | 34223979R | RESOLVE | Non-Hazardous | WORK WITHOUT A PERMIT. WORK NOTED: A 10 X 12 STRUCTURE ERECTED/CONST- RUCTED IN FRONT YARD OF PREMISES. STRUCTURE CON... | $400 | $0 | Oct 4, 1999 |
| Aug 21, 1999 | 34223980Y | RESOLVE | Non-Hazardous | ILLEGAL STORAGE/PARKING: IN SIDE AND REAR OF YARD OBSERVED 1 METALLIC GREY 1988 4 DOOR NISSAN MOTOR VEHICLE; 1 PONTIA... | $240 | $0 | Oct 4, 1999 |
| Aug 21, 1999 | 34223981X | RESOLVE | Non-Hazardous | FAILURE TO MAINTAIN: IN SIDE YARD AUTO PARTS, CONSTRUCTION DEBRIS AND A DRYER BEING STORED ON PREMISES. REMEDY: CLEAN... | $180 | $0 | Oct 4, 1999 |