| Feb 19, 2013 | A | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE CEILING LIGHT FIXTURE IN THE KITCHEN LOCATED AT APT 1, 1st... | 1 | May 25, 2013 |
| Feb 11, 2013 | B | VIOLATION DISMISSED | § 27-2005, 2006, 2037 HMC: PROPERLY REPAIR AND ABATE UNSAFE ELECTRIC WIRING CONDITION CONSISTING OF AT EAST WALL AT P... | — | Mar 18, 2013 |
| Feb 11, 2013 | B | VIOLATION CLOSED | § 27-2046.1, 2046.2 HMC: PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANC... | 1 | Mar 18, 2013 |
| Feb 11, 2013 | B | VIOLATION CLOSED | § 27-2037, 2038 HMC: PROVIDE A SAFE AND ADEQUATE SUPPLY OF ELECTRIC SERVICE TO THE FIXTURES AT CEILING IN THE PRIVATE... | 1 | Mar 18, 2013 |
| Feb 11, 2013 | B | VIOLATION CLOSED | § 27-2005 ADM CODE REPLACE WITH NEW THE MISSING LIGHT FIXTURE AT CEILING IN THE PRIVATE HALLWAY LOCATED AT APT 1, 1st... | 1 | Mar 18, 2013 |
| Feb 11, 2013 | B | NOT COMPLIED WITH | § 27-2005 ADM CODE MAKE SAFE BY PROPERLY REPAIRING THE STRUCTURAL DEFECT SLOPPING AND SAGGING FLOOR IN THE ENTIRE APA... | 1 | Mar 18, 2013 |
| Feb 11, 2013 | B | VIOLATION DISMISSED | § 27-2005, 2006, 2037 HMC: PROPERLY REPAIR AND ABATE UNSAFE ELECTRIC WIRING CONDITION CONSISTING OF AT CEILING IN THE... | 1 | Mar 18, 2013 |
| Feb 11, 2013 | B | VIOLATION DISMISSED | § 27-2005, 2006, 2037 HMC: PROPERLY REPAIR AND ABATE UNSAFE ELECTRIC WIRING CONDITION CONSISTING OF AT CEILING AT PUB... | — | Mar 18, 2013 |
| Feb 11, 2013 | B | VIOLATION CLOSED | § 27-2039 ADM CODE PROVIDE ADEQUATE LIGHT OF NOT LESS THAN 60 WATTS INCANDESCENT OR EQUIVALENT ILLUMINATION AT CEILIN... | — | Mar 18, 2013 |
| Feb 11, 2013 | B | VIOLATION CLOSED | § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF ILLEGAL ELECTRIC WIRE TAP AT EAST WALL TO CEILING L... | — | Mar 18, 2013 |
| Feb 11, 2013 | B | FIRST NO ACCESS TO RE- INSPECT VIOLATION | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CEMENT MORTAR JOINTS OF BRICK WORK 1... | — | Mar 18, 2013 |
| Feb 11, 2013 | A | VIOLATION CLOSED | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT CEILING AND WALLS AT PUBLIC ... | — | May 17, 2013 |
| Feb 7, 2013 | A | VIOLATION CLOSED | § 27-2026 ADM CODE RESET, SO AS TO SECURE A PROPER AND TIGHT CONNECTION, THE WATER CLOSET BOWL .. IN THE BATHROOM LOC... | 1 | May 13, 2013 |
| Feb 7, 2013 | B | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE ELECTRICAL LIGHT FIXTURE AT CEILING IN THE FOYER LOCATED A... | 1 | Mar 14, 2013 |
| Feb 7, 2013 | B | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY SECURE THE LOOSE WASHBASIN IN THE BATHROOM LOCATED AT APT 1, 1st STORY, 1st APARTMENT FRO... | 1 | Mar 14, 2013 |
| Feb 7, 2013 | B | VIOLATION DISMISSED | § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING LOCATED AT APT 1, 1st STORY, 1st ... | 1 | Mar 14, 2013 |
| Feb 7, 2013 | B | VIOLATION CLOSED | § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM NORTH... | 1 | Mar 14, 2013 |
| Feb 7, 2013 | B | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE ELECTRICAL OUTLET AT NORTH WALL IN THE 3rd ROOM FROM EAST ... | 1 | Mar 14, 2013 |
| Feb 7, 2013 | B | VIOLATION CLOSED | § 27-2005 ADM CODE REPLACE WITH NEW THE MISSING COVER FOR ELECTRICAL OUTLET AT SOUTH WALL IN THE BATHROOM LOCATED AT ... | 1 | Mar 14, 2013 |
| Jan 11, 2013 | A | VIOLATION CLOSED | § 27-2026 ADM CODE REPAIR THE BROKEN OR DEFECTIVE CONNECTION AT WASHBASIN WASTELINE IN THE BATHROOM LOCATED AT APT 2,... | 2 | Apr 16, 2013 |
| Nov 8, 2012 | B | VIOLATION CLOSED | § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). INOPERATIVE LOCATED AT APT 2, 2nd STORY, ... | 2 | Dec 13, 2012 |
| Oct 11, 2012 | C | VIOLATION CLOSED | § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PAINT THAT TESTED POSITIVE FOR LEAD CONTENT AND THAT IS ... | 2 | Nov 6, 2012 |
| Oct 11, 2012 | A | VIOLATION CLOSED | § 27-2024 ADM CODE PROVIDE ADEQUATE SUPPLY OF COLD WATER FOR THE FIXTURES ,,, IN THE BATHROOM LOCATED AT APT 2, 1st S... | 2 | Jan 14, 2013 |
| Oct 11, 2012 | C | VIOLATION CLOSED | § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PAINT THAT TESTED POSITIVE FOR LEAD CONTENT AND THAT IS ... | 2 | Nov 6, 2012 |
| Oct 11, 2012 | C | VIOLATION CLOSED | § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PAINT THAT TESTED POSITIVE FOR LEAD CONTENT AND THAT IS ... | 2 | Nov 6, 2012 |
| Oct 11, 2012 | C | VIOLATION CLOSED | § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PAINT THAT TESTED POSITIVE FOR LEAD CONTENT AND THAT IS ... | 2 | Nov 6, 2012 |
| Oct 11, 2012 | C | VIOLATION CLOSED | § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PAINT THAT TESTED POSITIVE FOR LEAD CONTENT AND THAT IS ... | 2 | Nov 6, 2012 |
| Oct 11, 2012 | A | VIOLATION CLOSED | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE 1st CLOSET FROM SOUTH AT... | 2 | Jan 14, 2013 |
| Oct 11, 2012 | A | VIOLATION CLOSED | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE CEILING IN THE 5th ROOM ... | 2 | Jan 14, 2013 |
| Oct 11, 2012 | A | VIOLATION CLOSED | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE WEST WALL IN THE 4th ROO... | 2 | Jan 14, 2013 |
| Oct 11, 2012 | A | VIOLATION CLOSED | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE EAST WALL, NORTH WALL, 1... | 2 | Jan 14, 2013 |
| Oct 11, 2012 | A | VIOLATION CLOSED | § 27-2005 ADM CODE PAINT METAL IN ACCORDANCE WITH DEPT. REGULATION THE 1st RADIATOR FROM EAST AT SOUTH WALL IN THE 2n... | 2 | Jan 14, 2013 |
| Oct 11, 2012 | A | VIOLATION CLOSED | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE CEILING, EAST WALL, SOUT... | 2 | Jan 14, 2013 |
| Oct 11, 2012 | C | VIOLATION CLOSED | § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PAINT THAT TESTED POSITIVE FOR LEAD CONTENT AND THAT IS ... | 2 | Nov 6, 2012 |
| Oct 11, 2012 | A | VIOLATION CLOSED | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT ALL PEELING PAINT SURFACES I... | 2 | Jan 14, 2013 |
| Oct 11, 2012 | B | VIOLATION CLOSED | § 27-2018 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF ROACHES LOCATED AT APT 2, 1st STORY, 2nd APARTMENT FROM NORTH... | 2 | Nov 15, 2012 |
| Oct 11, 2012 | A | VIOLATION CLOSED | § 27-2026 ADM CODE RESET, SO AS TO SECURE A PROPER AND TIGHT CONNECTION, THE WATER CLOSET BOWL ,,, IN THE BATHROOM LO... | 2 | Jan 14, 2013 |
| Oct 11, 2012 | B | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY SECURE THE LOOSE ELECTRICAL LIGHT FIXTURE AT CEILING IN THE 4th ROOM FROM EAST LOCATED AT... | 2 | Nov 15, 2012 |
| Sep 21, 2012 | A | VIOLATION CLOSED | § 27-2026 ADM CODE RESET, SO AS TO SECURE A PROPER AND TIGHT CONNECTION, THE WATER CLOSET BOWL ,, IN THE BATHROOM LOC... | 1 | Feb 23, 2013 |
| Sep 21, 2012 | B | VIOLATION CLOSED | § 27-2005, 2007 ADM CODE ARRANGE AND MAKE SELF-CLOSING THE DOORS ,, IN THE ENTRANCE LOCATED AT APT 1, 1st STORY, 1st ... | 1 | Nov 25, 2012 |
| Sep 21, 2012 | A | VIOLATION CLOSED | § 27-2043 ADM CODE PROVIDE A LOCK AND KEY TO THE ENTRANCE DOOR OF DWELLING UNIT AND, IF A CL A MULTIPLE DWELLING, ALS... | 1 | Feb 23, 2013 |
| Sep 20, 2012 | A | VIOLATION CLOSED | § 27-2005 ADM CODE PAINT METAL IN ACCORDANCE WITH DEPT. REGULATION , 1st RISER FROM EAST AT SOUTH WALL IN THE 3rd ROO... | 1 | Feb 22, 2013 |
| Sep 20, 2012 | A | VIOLATION CLOSED | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT , WEST WALL, SOUTH WALL, 1st... | 1 | Feb 22, 2013 |
| Sep 20, 2012 | C | VIOLATION CLOSED | § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PAINT THAT TESTED POSITIVE FOR LEAD CONTENT AND THAT IS ... | 1 | Oct 30, 2012 |
| Sep 20, 2012 | A | VIOLATION CLOSED | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT , 1st CLOSET FROM SOUTH AT W... | 1 | Feb 22, 2013 |
| Sep 20, 2012 | B | VIOLATION CLOSED | § 27-2005, 2007 ADM CODE FIRE EGRESS DEFECTIVE. REMOVE OBSTRUCTING BARS OR UNLAWFUL GATES FROM AT LEAST 1 WINDOW OR P... | 1 | Oct 25, 2012 |
| Sep 20, 2012 | C | VIOLATION CLOSED | § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PAINT THAT TESTED POSITIVE FOR LEAD CONTENT AND THAT IS ... | 1 | Oct 30, 2012 |
| Sep 20, 2012 | C | VIOLATION CLOSED | § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PAINT THAT TESTED POSITIVE FOR LEAD CONTENT AND THAT IS ... | 1 | Oct 30, 2012 |
| Sep 20, 2012 | C | VIOLATION CLOSED | § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PAINT THAT TESTED POSITIVE FOR LEAD CONTENT AND THAT IS ... | 1 | Oct 30, 2012 |
| Sep 20, 2012 | C | VIOLATION CLOSED | § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PAINT THAT TESTED POSITIVE FOR LEAD CONTENT AND THAT IS ... | 1 | Oct 30, 2012 |