| Mar 19, 2002 | 34317719H | RESOLVE | Non-Hazardous | FAILURE TO MAINTAIN BUILDING EXTERIOR DEFECT IS: MISSING SHEET METAL OVER ROLL GATE AT FRONT CRACKED MASONRY AND DEFE... | $2,500 | $0 | Jul 22, 2002 |
| Jan 27, 1999 | 34195740J | RESOLVE | Hazardous | FAILURE TO MAINTAIN BLDG EXTERIOR. DEFECT IS: LOOSE & HANGING SHEET METAL AT THE TOP OF ROLL GATE AT FRONT OF THE PRE... | $0 | $0 | Mar 29, 1999 |
| Jul 16, 1997 | 34160338L | RESOLVE | Non-Hazardous | FAILURE TO MAINTAIN BUILDING INTERIOR. WALLS AND CEILING FIRE RESTAURANT MISSING AT 2ND FLOOR AND STAIRWELL 1ST AND 2... | $800 | $0 | Jan 12, 1998 |
| May 16, 1995 | 34125855X | RESOLVE | Non-Hazardous | FAILURE TO MAINTAIN BLDG:DEFECT IS:7'CRACK IN FRONT WALL,FACING PITKIN+LINWOOD STREET.AND AT REAR CRACKS AND SPALDING... | $350 | -$110 | Dec 18, 1995 |
| May 13, 1992 | 34074013M | RESOLVE | Non-Hazardous | FAILURE TO MAINTAIN: FIRE RATING MISSING AT FIRST FLOOR CEILING AT JOIST AREA CENTER STORE AND AT WALLS AND CEILINGS ... | $0 | $0 | Aug 3, 1992 |
| May 13, 1992 | 34074014Y | RESOLVE | Non-Hazardous | WORK WITHOUT A PERMIT: SEALING OF WINDOWS AT REAR OF BUILDING FIRST FLOOR LEVEL WITHOUT A PERMIT FROM THIS DEPARTMENT... | $0 | $0 | Aug 3, 1992 |
| May 13, 1992 | 34074011Z | RESOLVE | Non-Hazardous | FAILURE TO PROVIDE VENTILATION FOR GAS HEATER LOCATED AT FRONT OF STORE FIRST FLOOR LEVEL. REMEDY-PROVIDE VENTILATION... | $0 | $0 | Aug 3, 1992 |
| May 13, 1992 | 34074012K | RESOLVE | Non-Hazardous | WORK WITHOUT PERMIT: HAVING PARTIALLY CLOSED EXISTING FRONT WITH MASONRY UNIT APPROXIMATELY 8 FT WIDE BY 8FT HIGH REM... | $0 | $0 | Aug 3, 1992 |
| May 13, 1992 | 34074010R | RESOLVE | Non-Hazardous | WORK WITHOUT PERMIT: REMOVAL OF SECTIONS OF PARTY WALL BETWEEN 2430-2432 PITKIN AVE AT FIRST FLOOR LEVEL. (SECTION AP... | $0 | $0 | Aug 3, 1992 |
| Jul 30, 1991 | 34059119P | RESOLVE | Non-Hazardous | OCCUPANCY CONTRARY TO THAT ALLOWED BY THE BUILDING DEPARTMENT RECORDS FROM LEGAL OCCUPANCY TO ILLEGAL OCCUPANCY USED ... | $0 | $0 | Nov 25, 1991 |
| Apr 21, 1989 | 34008962Z | RESOLVE | Hazardous | FAILURE TO MAINTAIN TREADS AND RISERS CRACKED AND BROKEN STAIRS LEADING TO FIRST FLOOR LEVEL RENMEDY: MAKE NECESSARY ... | $200 | $0 | Sep 11, 1989 |
| Apr 21, 1989 | 34008958X | RESOLVE | Unknown | WORK WITHOUT PERMIT. REMOVEAL OF SECTIONS OF PARTY WALL BETWEEN 2430-2432 PITKIN AVE AT FIRST FLOOR LEVEL.REMEDY:OBTA... | $0 | $0 | Sep 11, 1989 |
| Apr 12, 1989 | 34008960P | RESOLVE | Unknown | WORK WITHOUT A PERMIT: SEALING OF WINDOUS AT REAR OF BUILDING FIRST FLOOR LEVEL WITHOUT PERMIT FROM THIS DEPT REMEDY:... | $0 | $0 | Sep 11, 1989 |
| Apr 12, 1989 | 34008961R | RESOLVE | Unknown | FAILER TO PROVIDE VENTILATION FOR GAS HEATER LOCATED AT FRONT OF STORE FIRST FLOOR LEVEL REMEDY: PROVIDE VENTILATION ... | $50 | $0 | Sep 11, 1989 |
| Apr 12, 1989 | 34008963K | RESOLVE | Unknown | WORK WITHOUT A PERMIT. HAVE PARTIALLY CLOSED EXISTING FRONT WITH MASONARY UNITS APPROXIMATELY 8 FEET WIDE BY 8 FEET H... | $250 | $0 | Sep 11, 1989 |