ECB violations
1004-1006 Blake Avenue, Brooklyn • Block 04067 • Lot 0022
29 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Feb 25, 2026 | 39178268M | ACTIVE | CLASS - 2 | FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER TO FILE A CERTIFICATE OF CORRECTION WITH THE DEPARTMENT OF BUILDINGS ... | $6,250 | $6,250 | May 6, 2026 |
| Feb 25, 2026 | 39178267K | ACTIVE | CLASS - 1 | FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER FOR VIOLATION # 39135192P .NO FIRE STOPPING PER BC 712.3 (2014 ... | $25,000 | $25,000 | May 6, 2026 |
| Oct 24, 2025 | 39164718N | ACTIVE | CLASS - 3 | @CELLAR AO SMITH HOT WATER HEATER#1 HAS CORRODED SAFETY VALVE PIPE+#3 HWH IS INOPERABLE+ALL HWH'S ARE MISSING CONDENS... | $500 | $0 | Jan 7, 2026 |
| Oct 22, 2025 | 39164374Z | ACTIVE | CLASS - 2 | OBSERVED ON THE FIRST FLOOR IN THE KITCHEN NO TRAP UNDER SINK WHICH CONTRARY CODE SECTION PC 1002.1, REPAIR AND/OR RE... | $1,250 | $0 | Jan 7, 2026 |
| Jan 29, 2025 | 37033095N | ACTIVE | CLASS - 2 | FAILURE TO COMPLY WITH COMMISSIONER'S ORDER CONTAINED IN SUMMONS #39097339X ISSUED ON 10/18/2023, AND FAILURE TO FILE... | $6,250 | $6,250 | Oct 22, 2026 |
| Jan 10, 2025 | 39135196M | ACTIVE | CLASS - 1 | I OBSERVED IN THE ELEVATOR MOTOR DISCONNECT THE IMPROPER FUSING OF THE CONDUCTORS, ALL FUSES SHALL BE OF THE SAME AMP... | $4,800 | $4,800 | Apr 20, 2026 |
| Jan 10, 2025 | 39135193R | ACTIVE | CLASS - 2 | EXIT DOOR NOT SELF-CLOSING. OBSERVED NON SELF CLOSING DOOR AT GAS METER ROOM IN BASEMENT. POTENTIAL FIRE HAZARD., REP... | $625 | $625 | Apr 20, 2026 |
| Jan 10, 2025 | 39135195K | ACTIVE | CLASS - 2 | I OBSERVED IN THE ELEVATOR MOTOR ROOM THE UNPERMITTED USE OF FLEXIBLE CORDS AS PERMANENT WIRING AS EC 400.8 THIS IS N... | $800 | $800 | Apr 20, 2026 |
| Jan 10, 2025 | 39135192P | ACTIVE | CLASS - 1 | FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER: NO FIRE STOPPING PER BC 712.3 (2014 CODE); 27-345; BC 711.2.4 ... | $2,530 | $2,530 | Dec 14, 2026 |
| Jan 10, 2025 | 39135191N | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. OBSERVED INSTALLED PVC PIPING FOR HOT WATER INSTEAD THE CORREC... | $0 | $0 | Sep 8, 2025 |
| Jul 3, 2024 | 39118386Z | RESOLVE | CLASS - 1 | CLASS 1: CEASE USE ITEMS - REPAIR ONE OF TWO ITEMS (A) IN-CAR EMERGENCY PHONE OR (B) IN-CAR ALARM SYSTEM., ADJUST THE... | $3,125 | $0 | Sep 11, 2024 |
| Oct 18, 2023 | 39097339X | ACTIVE | CLASS - 2 | SPRINKLER HEADS ON THE 1ST AND 3RD FLOOR OBSTRUCTED BY CEILING. AS PER 102.3 MAINTENANCE. INSTALLATIONS, BOTH EXISTIN... | $625 | $0 | Dec 27, 2023 |
| Mar 30, 2022 | 35650608K | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN BLDG IN CODECOMPLIANT MANNER:OBSERVED:@CELLAR LEVEL,FOUNDATION WALLS,SEVERAL HOLES MISSING STONES... | $312 | $0 | Nov 22, 2022 |
| Mar 30, 2022 | 35650606R | RESOLVE | CLASS - 2 | EXIT DOOR NOT SELFCLOSING.OBSERVED:FIREPROOF SELFCLOSING DOOR,@3FL,STAIRCASEB@1FL,STAIRCASEA,DININGRM DOORS(2)&MAIN E... | $312 | $0 | Sep 19, 2022 |
| Mar 30, 2022 | 35650607Z | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN BLDSG IN CODECOMPLIANT MANNER:NO FIRESTOPPING PER BC312.3;27-345 OBSERVED:@1FL,ELECTRICAL RM@CELL... | $625 | $0 | Nov 22, 2022 |
| Nov 9, 2021 | 39050889M | RESOLVE | CLASS - 2 | NOTED: OBSERVED EXISTING EMERGENCY LIGHTS AT 3RD. FLOOR STAIR B, 2ND FLOOR STAIR A, BY ROOM 204, 1ST. FLOOR STAIR A, ... | $312 | $0 | Aug 17, 2022 |
| Nov 9, 2021 | 39050898Y | RESOLVE | CLASS - 2 | I OBSERVED IN THE CELLAR LOCATED UNDER THE STREET HATCH (4) GAS FIRED WATER HEATERS WITH NO REMOTE SHUTDOWNS AS REQUI... | $1,250 | $0 | Aug 17, 2022 |
| Nov 9, 2021 | 39050899X | RESOLVE | CLASS - 2 | I OBSERVED IN KITCHEN COMMERCIAL DISCONNECT ON FREE STANDING COMMERCIAL COOKING EQUIPMENT. AS PER FGC COMMERCIAL COOK... | $625 | $0 | Aug 17, 2022 |
| Nov 9, 2021 | 39050897M | RESOLVE | CLASS - 2 | I OBSERVED IN THE REAR COURTYARD A WALL LIGHT HANGING WITH THE RACEWAY DETACHED AND THE CONDUCTORS EXPOSED. ALSO NOTE... | $400 | $0 | Aug 17, 2022 |
| Nov 9, 2021 | 39050890J | RESOLVE | CLASS - 2 | NOTED: BOTH EXTERIOR EXIT DOORS LEADING OUT TO LINWOOD STREET DO NOT SELF CLOSE, DOORS REMAIN IN AN OPEN POSITION WHE... | $312 | $0 | Aug 17, 2022 |
| Oct 13, 2021 | 39049197N | RESOLVE | CLASS - 1 | DOOR ZONE RESTRICTOR NOT WORKING TAMPERED WITH DISABLED (CU). EMERGENCY STOP SWITCH NO BUZZER(CU). ALARM BELL NO BUZZ... | $1,250 | $0 | Feb 16, 2022 |
| Mar 9, 2020 | 39019213R | RESOLVE | CLASS - 1 | HYDRAULIC PACKING HEAVY OIL LEAK (CU). CONSTANT RE- LEVELING AT THE FLOORS WITH THE DOORS OPENED PROPERLY ADJUST HYDR... | $3,125 | $0 | Dec 28, 2020 |
| Jan 11, 2019 | 38267329P | RESOLVE | CLASS - 2 | 48B1)DEVICE CONSTANTLY RELEVELING, ADJUST RELEVELING CONDITION. | $1,562 | $0 | Oct 2, 2019 |
| Aug 6, 2018 | 35345999X | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER. NOTED: OBSERVED @ 3RD FLR STAIR 'A' DOOR LEADING TO STAIRWELL IS R... | $1,562 | -$1,562 | Oct 22, 2018 |
| Nov 20, 2017 | 35297181X | RESOLVE | CLASS - 1 | 403.8 UNPAINTED GAS PIPING NOT PROTECTED FROM CORROSIAN.OBSERVED ON 11.20/17 AT ABOVE ADDRESS UNPAINTED GAS PIPE TO T... | $4,000 | $0 | Jun 20, 2018 |
| Oct 20, 2017 | 38258832H | RESOLVE | CLASS - 1 | 42G7. 42G7 CONTROLLER HAS A BYPASSED FUSE 10 AMP,REPLACE,PROVIDE. | $2,500 | $0 | Feb 21, 2018 |
| Jun 29, 2017 | 35271707X | RESOLVE | CLASS - 1 | MISC VIOLATIONS: UNPAINED GAS PIPING NOT PROTECTED FROM THE ELEMENTS. OBSERVED ON ROOF GAS PIPING TO THREE HVAC UNITS... | $1,600 | $0 | Sep 11, 2017 |
| Apr 17, 2013 | 35009459M | RESOLVE | CLASS - 1 | FAILURE TO GROUND ELECTRICAL SYSTEMS. NO WATER MAIN GROUND ELECTRICAL SERVICE,CELLSITE JUMPER AND AUX GROUND ROD. AT ... | $4,800 | $0 | Jun 3, 2013 |
| Apr 8, 2013 | 38226505Y | RESOLVE | CLASS - 3 | 97R05 - DEVICE REMOVED W/O PERMIT. NO RECORD OF APPLICATION. | $100 | $0 | Jun 3, 2013 |