ECB violations
611 Barbey Street, Brooklyn • Block 04077 • Lot 0024
27 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Jun 17, 2026 | 39192910L | ACTIVE | CLASS - 1 | FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. OBSERVED FIRE ESCAPE DROP LADDER. OBSTRUCTED BY FIXED BENCH. L... | $6,250 | $0 | Jul 9, 2026 |
| Jun 17, 2026 | 39192819K | ACTIVE | CLASS - 2 | HYDROTHERM BOILER MISSING RATINGS LABEL, MOTORIZED COMBUSTION AIR LOUVER MISSING WHISKER SWITCH. CORRECT VIOLATING CO... | $1,250 | $0 | Jul 9, 2026 |
| Jun 24, 2025 | 39151854P | ACTIVE | CLASS - 1 | & BC 1024.2 (2022 CODE) FAILURE TO PROVIDE UNOBSTRUCTED EXIT PASSAGEWAY. FIRE ESCAPE OBSTRUCTED WITH FIXED PARK BENCH... | $1,250 | $0 | Jun 30, 2025 |
| Jun 24, 2025 | 39151853N | ACTIVE | CLASS - 1 | FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER: NO FIRE STOPPING PER BC 712.3 (2014 CODE); 27-345; BC 711.2.4 ... | $2,500 | $0 | Jun 30, 2025 |
| Apr 30, 2024 | 39112986P | ACTIVE | CLASS - 2 | HYDROTHERM MODEL-MR1200 BOILER. MISSING BOILER RATING TAG, MISSING WISKER SWITCH ON FRESH AIR LOUVER. CORRECT VIOLATI... | $625 | $0 | Jun 13, 2024 |
| Aug 31, 2022 | 39069230Y | ACTIVE | CLASS - 2 | AT CELLAR/BASEMENT LEVEL JIM CAP INSTALLED AND ALSO NOT HOLDING ON 4 INCH CAST IRON FITTING. THIS IS A HAZARDOUS COND... | $625 | $0 | Sep 20, 2022 |
| Aug 31, 2022 | 39069438N | ACTIVE | CLASS - 2 | I OBSERVED IN THE PREVIOUS LAUNDRY ROOM IN THE BASEMENT THE UNPERMITTED USE OF A FLEXIBLE CORD AS PERMANENT WIRING SU... | $800 | $0 | Feb 1, 2023 |
| Aug 31, 2022 | 39069439P | ACTIVE | CLASS - 2 | I OBSERVED IN THE BASEMENT ELECTRICAL EQUIPMENT ROOM THE GROUND CONDUITS IN A STATE OF CORROSION. ALL SECTIONS OF THE... | $800 | $0 | Feb 1, 2023 |
| Sep 24, 2021 | 39048113M | ACTIVE | CLASS - 2 | SAFETY DISCHARGE PIPE INCORRECT/FRONT JACKET NOT IN PLACE/OPENING IN BOILER ROOM DOOR/DEBRIS IN BOILER ROOM;CORRECT V... | $625 | $0 | Oct 15, 2021 |
| Sep 24, 2021 | 39048114Y | ACTIVE | CLASS - 2 | #1 CIRCULATOR CORRODED AND GAUGE IS DEFECTIVE/MOTORIZED LOUVER NOT INTERLOCKED WITH ALL UNITS AND WHISKER SWITCH INST... | $625 | $0 | Oct 15, 2021 |
| Nov 15, 2019 | 39012935R | RESOLVE | CLASS - 2 | NOTED: BUILDING ALTERED AND OCCUPIED AS A HOMELESS SHELTER UNDER AN EXPIRED TEMPORARY CERTIFICATE OF OCCUPANCY, T.C.O... | $3,125 | $0 | Nov 18, 2019 |
| Nov 15, 2019 | 39012934P | RESOLVE | CLASS - 2 | NOTED: OBSERVED ON THE FOURTH FLOOR, HALLWAY CEILING HAS DAMAGE TO THE FIRE RATED WALLBOARD NEXT TO LIGHT FIXTURE DUE... | $625 | $0 | Nov 18, 2019 |
| Feb 12, 2018 | 35311743R | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER. OBSERVED IN CELLAR JIM CAPS INSTALLED ON THE SANITARY DRAINAGE SYS... | $0 | $0 | Apr 23, 2018 |
| Jul 21, 2017 | 35272049H | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER. OBSERVED ON 7/21/17@ ABOVE ADDRESS JIM CAPS INSTALLED THROUGHOUT B... | $0 | $0 | Dec 18, 2017 |
| Jul 21, 2017 | 35272048X | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER.OBSERVED ON 7/21/17 AT ABOVE ADDRESS ACETYLEWE TANK BEING STORE... | $0 | $0 | Oct 16, 2017 |
| Oct 14, 2016 | 35214531K | RESOLVE | CLASS - 1 | SEC: FGC 401.5.GAS PIPING NOT LABELED. @ TIME OF INSP 10:25AM ON 10/14/16 @ THE ABOVE PLACE OF OCCURENCE ADDRESS I OB... | $0 | $0 | Nov 14, 2016 |
| Oct 14, 2016 | 35216151H | RESOLVE | CLASS - 2 | ALTERED/CHANGED BLDG OCCUPIED W/OUT A VALID C OF O AS PER 28-118.3-1-28-118.3.2. NOTE: PREMISES OCCUPIED UNDER TEMPOR... | $0 | $0 | Nov 14, 2016 |
| Mar 29, 2016 | 35177391H | RESOLVE | CLASS - 2 | ALTERED BLDG OCCUPIED W/OUT A VALID C OF O PER 28-118.3.1, 28-118.3.2. NOTED: BLDG ALTERED UNDER JOB#300050307 ALT I ... | $0 | $0 | Jul 18, 2016 |
| Mar 29, 2016 | 35177390X | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN BLDG CODE COMPLIANT. NOTED: @ BARBEY STREET FRONTAGE, METAL WINDOW GATE INSTALLED AROUND AIR COND... | $0 | $0 | Jul 18, 2016 |
| Mar 29, 2016 | 35177392J | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN BLDG CODE COMPLIANT: NO FIRE STOPPING PER BC 712.3, 27-345. NOTED: @ CELLAR WORK SHOP, APPROX 2'X... | $0 | $0 | Jun 22, 2016 |
| Oct 13, 2009 | 34815816L | RESOLVE | CLASS - 1 | INADEQUATE SAFETY MEASURES: OPERATION OF HOISTING EQUIPMENT IN UNSAFE MANNER. NOTED: UPON RE-INSPECTION FOUND OUT RIG... | $24,000 | $0 | Aug 23, 2010 |
| Oct 7, 2009 | 34809067M | RESOLVE | CLASS - 1 | ERECTED,DISMANTLED REPAIRED,MAINTAIN,MODIFIED OR REMOVED SUPPORTED SCAFFOLD W/O SCAFFOLD CERTIFICATE OF COMPLETION.NO... | $0 | $0 | May 13, 2010 |
| Oct 7, 2009 | 34809066K | RESOLVE | CLASS - 2 | FAILURE TO PROVIDE APPROVED/ACCEPTED PLANS @ JOB SITE @ TIME OF INSPECTION.NOTED:NO APPROVED PLANS FOR SUPPORTED SCAF... | $250 | $0 | May 13, 2010 |
| Oct 7, 2009 | 34809065Z | RESOLVE | CLASS - 2 | FAILED TO NOTIFY DEPARTMENT/OBTAIN PERMIT PRIOR TO USE/ INSTALLATION OFF OUTRIGGER BEAMS IN CONNECTION WITH SUSPENDED... | $400 | $0 | May 13, 2010 |
| Feb 26, 2009 | 34756192P | RESOLVE | CLASS - 2 | FAILED TO NOTIFY THE DEPT OBTAIN PERMIT ORIOR TO USE INSTALLATION OFF C HOOKS IN CONNECTION WITH SUSPENDED SCAFFOLD N... | $400 | $0 | Nov 25, 2009 |
| Feb 26, 2009 | 34756194Z | RESOLVE | CLASS - 1 | FAILURE TO FILE EVIDENCE OF LIABILITY AND OR DAMAGE INSURANCE EXP LIABILITY INSURANCE ON 12/11/08 REMEDY: OBTAIN BOND... | $0 | $0 | Jan 15, 2010 |
| Feb 26, 2009 | 34756193R | RESOLVE | CLASS - 2 | LICENSED SPECIAL RIGGER FAILED TO PLACE APPROPRIATE DANGER SIGN WHILE USING RIGGING EQUIPMENT NO DANGER SIGNS POSTED ... | $400 | $0 | Nov 25, 2009 |