ECB violations
554-558 Jerome Street, Brooklyn • Block 04077 • Lot 0028
24 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Jun 17, 2026 | 39192847H | ACTIVE | CLASS - 2 | HYDROTHERM BOILER IS MISSING RATINGS LABEL. CORRECT VIOLATING CONDITIONS AND SUBMIT A CERTIFICATE OF CORRECTION. | $1,250 | $0 | Jul 9, 2026 |
| Jun 24, 2025 | 39151881K | ACTIVE | CLASS - 1 | FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER: NO FIRE STOPPING PER BC 712.3 (2014 CODE); 27-345; BC 711.2.4 ... | $2,500 | $0 | Jun 30, 2025 |
| Apr 30, 2024 | 39112991J | ACTIVE | CLASS - 2 | HYDROTHERM MODEL- MR 1200 BOILER. MISSING WHISKER SWITCH, MISSING BOILER RATING TAG, BOILER ROOM DOOR DOESN'T OPEN TO... | $625 | $0 | Jun 13, 2024 |
| Aug 31, 2022 | 39069294N | ACTIVE | CLASS - 2 | JIM CAPS INSTALLED ON CAST IRON PIPPING IN BASEMENT/CELLAR., REPAIR AND/OR REPLACE | $625 | $0 | Sep 20, 2022 |
| Aug 31, 2022 | 39069335K | ACTIVE | CLASS - 2 | I OBSERVED IN THE WATER METER ROOM NO WATER METER JUMPER INSTALLED., PROVIDE ADEQUATE GROUNDING; INSTALL WATER METER ... | $2,400 | $0 | Sep 20, 2022 |
| Aug 31, 2022 | 39069334Z | ACTIVE | CLASS - 2 | I OBSERVED IN THE LAUNDRY ROOM THE SUPPLY CORD IMPROPERLY TERMINATED WITH ELECTRICAL TAPE COVERING EXPOSED CONDUCTORS... | $800 | $0 | Sep 20, 2022 |
| Aug 31, 2022 | 39069295P | ACTIVE | CLASS - 2 | I OBSERVED NO SPRINKLERS OR FIRE PROTECTION IN THE LAUNDRY ROOM AS PER CODE BC903.2.11.13, REPAIR AND/OR REPLACE | $625 | $0 | Sep 20, 2022 |
| Oct 12, 2021 | 39049144J | ACTIVE | CLASS - 2 | DOOR TO BOILER ROOM NOT EGRESS,SEAL LOUVER ON DOOR TO BOILER ROOM TO BE SEALED,MISSING RATING PLATE ON BOILER,PROVE S... | $625 | $0 | Oct 15, 2021 |
| Sep 24, 2021 | 39048191H | ACTIVE | CLASS - 1 | I OBSERVED A GAS LEAK IN THE GAS METER ROOM ON THE DRESSER COUPLING. NATIONAL GRID SHUT AND LOCKED THE METER THERE 21... | $1,250 | $0 | Oct 15, 2021 |
| Nov 15, 2019 | 39012942P | RESOLVE | CLASS - 2 | NOTED: BUILDING ALTERED AND OCCUPIED AS A HOMELESS SHELTER UNDER AN EXPIRED TEMPORARY CERTIFICATE OF OCCUPANCY, T.C.O... | $3,125 | $0 | Nov 18, 2019 |
| Nov 15, 2019 | 39012941N | RESOLVE | CLASS - 2 | NOTED: OBSERVED ON THE THIRD AND FOURTH FLOOR STAIRWELL NEAR WINDOWS, SPALLING AND BULGING PLASTER DUE TO WATER PENET... | $625 | $0 | Nov 18, 2019 |
| Aug 3, 2018 | 35316311X | RESOLVE | CLASS - 3 | FAILURE TO MAINTAIN BUILDING IN A CODE COMPLIANT MANNER.NOTE:AT INSPECTION 3RD &4TH FLOOR STAIR CASE WALLS ARE SPALLI... | $0 | $0 | Oct 29, 2018 |
| May 7, 2018 | 35313259Y | RESOLVE | CLASS - 1 | AN UNLAWFUL ACT,FAILURE TO COMPLY WITH AN ORDER TO THE COMMISSIONER.FAILURE TO CORRECT AND CERTIFY SUMMONS#35286711K,... | $6,250 | $6,250 | Jul 9, 2018 |
| Feb 22, 2018 | 35312852K | RESOLVE | CLASS - 1 | UNLAWFUL ACTS FAILURE TO COMPLY WITH AN ORDER OF THE COMMISSIONER. RECORDS INDICATE NO APPLICATION WAS MADE TO CORREC... | $0 | $0 | Apr 23, 2018 |
| Feb 12, 2018 | 35311744Z | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER. OBSERVED IN CELLAR JIM CAPS INSTALLED ON THE SANITARY DRAINAGE SYS... | $0 | $0 | Apr 23, 2018 |
| Dec 13, 2017 | 35274221J | RESOLVE | CLASS - 1 | UNLAWFUL ACT,FAILURE TO COMPLY WITH AN ORDER OF THE COMMISSIONER.RECORDS INDICATE NO APPLICATION FILED TO CERTIFY,COR... | $12,000 | $0 | Jan 29, 2018 |
| Jul 21, 2017 | 35286711K | RESOLVE | CLASS - 1 | UNAPPROVED, UNSAFE, UNSUITABLE ELECTRICAL EQUIPMENT, APPARATUS, DEVICES, MATERIALS, APPLIANCES OR WIRING IN USE. OBSE... | $0 | $0 | Dec 18, 2017 |
| Oct 14, 2016 | 35216153L | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER: NO FIRE STOPPING PER BC712.3; 27-345. NOTE: NO FIRE STOPPING @ ELE... | $0 | $0 | Nov 14, 2016 |
| Oct 14, 2016 | 35216152J | RESOLVE | CLASS - 2 | ALTERED/CHANGED BLDG OCCUPIED W/OUT A VALID C OF O AS PER 28-118.3.1-28-118.3.2. NOTE: PREMISES OCCUPIED UNDER TEMPOR... | $0 | $0 | Nov 14, 2016 |
| Oct 14, 2016 | 35214534X | RESOLVE | CLASS - 2 | FAILURE TO MAINTENANCE BLDG IN CODE COMPLIANT MANNER: FAILURE TO COMPLY W/ LAW FOR DRAINAGE SYSTEM PER PC702.1;27-911... | $0 | $0 | Nov 14, 2016 |
| Oct 14, 2016 | 35214533Y | RESOLVE | CLASS - 2 | FAIL TO MAINTAIN BLDG IN CODE COMPLIANT MANNER, REINSTALLATION/MAINTENANCE/MAINTENANCE OF PLUMBING MATERIALS/EQUIPMEN... | $0 | $0 | Nov 14, 2016 |
| Oct 14, 2016 | 35214532M | RESOLVE | CLASS - 1 | SEC: FGC411.1. RESIDENTIAL GAS FLEX USED ON COMMERCIAL EQUIPMENT. @ TIME OF INSP 10:40AM ON 10/14/16 @ THE ABOVE PLAC... | $0 | $0 | Nov 14, 2016 |
| Oct 13, 2009 | 34815817N | RESOLVE | CLASS - 1 | INADEQUATE SAFETY MEASURES : OPERATION OF HOISTING EQUIPMENT IN INSAFEMANNER NOTED: UPON RE-INSPECTION OF JOB SITE, F... | $24,000 | $0 | Aug 23, 2010 |
| Oct 7, 2009 | 34809064R | RESOLVE | CLASS - 2 | FAILED TO NOTIFY DEPT/OBTAIN PERMIT PRIOR TO USE/INSTALLATION OFF "C" HOOKS IN CONNECTION W/ SUSPENDED SCAFFOLD.NOTED... | $400 | $0 | May 13, 2010 |