ECB violations
2-40 Richmond Street, Brooklyn • Block 04102 • Lot 0019
28 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Mar 27, 2026 | 35727516X | ACTIVE | CLASS - 2 | EXIT DOOR NOT SELF-CLOSING. AT THE TIME OF INSPECTION, THE FOLLOWING EXIT DISHARGE DOORS WERE NOT SELF-CLOSING:-EXIT ... | $625 | $0 | May 12, 2026 |
| Mar 27, 2026 | 35727515Y | ACTIVE | CLASS - 2 | RE-ISSUE 35692091M. AT THE TIME OF INSPECTION, ROOM 519 HAD LEAKS NEARTHE SPRINKLER HEAD, ROOMS 515, 516 AND LIBRARY ... | $3,125 | $0 | May 12, 2026 |
| Mar 27, 2026 | 35727514M | ACTIVE | CLASS - 2 | RE-ISSUE 35692092Y. AT THE TIME OF INSPECTION THE FOLLOWING DOORS WERENOT SELF-CLOSING:-BULKHEAD DOOR TO ROOF, 517, 2... | $3,125 | $0 | May 12, 2026 |
| Jun 26, 2025 | 39152126L | ACTIVE | CLASS - 2 | RESTORE SERVICE TO DEVICE. | $625 | $0 | Jun 30, 2025 |
| Apr 23, 2025 | 35692091M | ACTIVE | CLASS - 2 | REISSUE #35663297P: FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER: WATER INFILTRATION FROM OUTSIDE ELEMENT TH... | $3,125 | $0 | May 22, 2025 |
| Apr 23, 2025 | 35692092Y | ACTIVE | CLASS - 2 | REISSUE #35644342L: FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. SMOKE DOORS NOT SELF-CLOSING WHEN TESTED N... | $3,125 | $0 | May 22, 2025 |
| Jul 30, 2024 | 39120331Y | ACTIVE | CLASS - 2 | RTS CLASS 2: FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. UPON INSPECTION, THE DEVICE IS FOUND TO BE OUT OF... | $625 | $0 | Aug 28, 2024 |
| Feb 23, 2024 | 35678650Z | RESOLVE | CLASS - 2 | RE-ISSUE #35663299Z. ALTERED/CHANGED BUILDING OCCUPIED WITHOUT A VALIDCERTIFICATE OF OCCUPANCY AS PER S28-118.3.1/S28... | $3,125 | $0 | Apr 22, 2024 |
| Feb 2, 2023 | 35663298R | RESOLVE | CLASS - 2 | REISSUE#35644342L 2/4/2022.FAILRUE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER.NOTED OBSERVED DURING INSPECTION DOO... | $1,562 | $0 | May 10, 2023 |
| Feb 2, 2023 | 35663299Z | RESOLVE | CLASS - 2 | ALTERED/CHANGED BUILDING OCCUPIED WITHOUT A VALID CERTIFICATE OF OCCUPANCY AS PER 28-118.3.1,28-118.3.2.NOTED OBSERVE... | $1,250 | $0 | May 10, 2023 |
| Feb 2, 2023 | 35671650R | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER.NOTED OBSERVED DURING INSPECTION OF WINDOWS IN MAIN ENTRANCE AR... | $625 | $0 | May 10, 2023 |
| Feb 2, 2023 | 35663297P | ACTIVE | CLASS - 2 | REISSUE#35644344P 2/4/2022.FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER.NOTED OBSERVED DURING INSPECTION OF ... | $1,562 | $0 | May 10, 2023 |
| Feb 4, 2022 | 35644344P | ACTIVE | CLASS - 2 | FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER.WATER PENETRATION AT ROOM 515 & 516 ROOM 201 ROOM B19 ELECTRIC ... | $1,562 | $0 | Jun 22, 2022 |
| Feb 4, 2022 | 35644343N | RESOLVE | CLASS - 2 | EXIT DOOR NOT SELF CLOSING AT BULKHEAD ROOF RM B15,B11 ARE NOT OPERATIONAL AS TESTED.REISSUE #35553676H REMEDY:REPAIR... | $1,562 | $0 | Jun 22, 2022 |
| Feb 4, 2022 | 35644342L | ACTIVE | CLASS - 2 | FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER.AT ROOFTOP BULKHEAD NOT CLOSE PROPERLY AT HALLWAY NEAR RM B15 N... | $1,562 | $0 | Jun 22, 2022 |
| Feb 10, 2021 | 35553675X | ACTIVE | CLASS - 2 | REISSUE ECB#35500907R FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER. NOTED: AT(5TH FL)ROOMS 515&516(3RD FL)RM 301... | $1,562 | $0 | Jul 7, 2021 |
| Feb 10, 2021 | 35553677J | ACTIVE | CLASS - 2 | REISSUE ECB#35383995X FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER. NOTED: AT ROOF LEVEL BULKHEAD STAIR'A' 2ND F... | $1,562 | $0 | Jul 7, 2021 |
| Feb 10, 2021 | 35553676H | RESOLVE | CLASS - 2 | REISSUE ECB#35500906P EXIT DOOR NOT SELF CLOSING. NOTED: AT(ROOF LEVEL)BULKHEAD STAIRCASES(BASEMENT)ROOMS B15 & B11 D... | $1,562 | $0 | Jul 7, 2021 |
| Jun 12, 2020 | 35500906P | RESOLVE | CLASS - 2 | EXIT DOOR IS NOT SELF CLOSE. NOTED: BULKHEAD DOOR NOT CLOSED PROPERLY,ALSO ROOM B15 & B11. REMEDY: REPAIR & ON REPLACE. | $625 | $0 | Dec 23, 2020 |
| Jun 12, 2020 | 35500907R | ACTIVE | CLASS - 2 | FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER. NOTED: WATER PENETRATION ROOM 516 & 515 FROM CEILING WATER COME TH... | $625 | $0 | Dec 23, 2020 |
| Oct 9, 2019 | 35453238J | RESOLVE | CLASS - 2 | FAILURE TO POST OR PROPERLY POST PERMIT FOR WORK AT PREMISES. AT TIME OF INSPECTION OF NB,5 STY BLDG AT EXCAVATION PH... | $1,562 | $1,562 | Feb 12, 2020 |
| Feb 11, 2019 | 35383995X | ACTIVE | CLASS - 2 | REISSUED 35311567R (1/25/18) @ STAIR A 5TH FLOOR BULKHEAD DORO IS NOT OPEN PROPERLY, 1ST FLOOR ADJACENT TO ROOM 121 A... | $0 | $0 | Jun 10, 2019 |
| Jan 25, 2018 | 35311567R | ACTIVE | CLASS - 2 | FAILURE TO MAINTAIN BLDG IN CODE-COMPLIANT MANNER. NOTED AT 1ST FLOOR,SMOKE DOOR ADJACENT TO ROOM #121 AND AT THE 2ND... | $0 | $0 | Apr 23, 2018 |
| Jun 22, 2015 | 35129186M | ACTIVE | CLASS - 2 | OPERATION OF A PLACE OF ASSEMBLY W/OUT A CURRENT CERT OF OPERATION.PA#302107789 (GYMNASIUM) & PA#302107770 UNCOMPLETE... | $0 | $0 | Aug 17, 2015 |
| Jun 22, 2015 | 35129189H | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN BLDG WALLS OR APPURTENANCES.WATER PENETRATION FROMROOF INTO RM (505).REM:MAINTAIN ROOF. | $0 | $0 | Aug 17, 2015 |
| Oct 24, 2014 | 38232971M | RESOLVE | CLASS - 2 | /52B14/ SHORTEN HOIST ROPES. | $0 | $0 | Dec 15, 2014 |
| Oct 24, 2014 | 38232970K | RESOLVE | CLASS - 2 | /52B14/ SHORTEN HOIST ROPES. | $0 | $0 | Dec 15, 2014 |
| Jun 2, 2008 | 34636395Z | RESOLVE | Non-Hazardous | FAILURE TO PROVIDE CONTRACTORS SIGN FOR SIDEWALK SHED. REMEDY: PROVIDECONTRACTORS SIGN. | $5,000 | $0 | Jul 6, 2009 |