Maintenance code violations
163-167 Fountain Avenue, Brooklyn • Block 04210 • Lot 0012
280 records
HPD grades a violation A for non-hazardous through C for immediately hazardous.
| Issued | Class | Status | Violation | Apartment | Correct by |
|---|---|---|---|---|---|
| May 13, 2021 | B | VIOLATION WILL BE REINSPECTED | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC FLOOR TILES IN THE BATHROOM ... | 4 | Jun 17, 2021 |
| May 13, 2021 | B | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE SPRING BALANCE UPPER SASH AT THE 2ND WINDOW FROM EAST AT S... | 4 | Jun 17, 2021 |
| May 13, 2021 | B | VIOLATION CLOSED | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING AT PUBLIC HALL, 2nd... | — | Jun 17, 2021 |
| May 13, 2021 | B | VIOLATION WILL BE REINSPECTED | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT THE CEILING AND SOUTH... | — | Jun 17, 2021 |
| May 13, 2021 | A | VIOLATION CLOSED | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE CEILING AND SOUTH WALL A... | — | Aug 16, 2021 |
| May 13, 2021 | B | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT THE CEILING , NORTH W... | — | Jun 17, 2021 |
| May 13, 2021 | A | VIOLATION DISMISSED | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE CEILING , NORTH WALL AND... | — | Aug 16, 2021 |
| May 13, 2021 | B | VIOLATION CLOSED | § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK OVER THE CEILING AT PUBLIC HALL, 3rd STORY | — | Jun 17, 2021 |
| May 13, 2021 | B | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC FLOOR TILES AT THE VESTIBLE ... | — | Jun 17, 2021 |
| May 13, 2021 | B | NOT COMPLIED WITH | § 27-2005, 2006, 2037 HMC: PROPERLY REPAIR AND ABATE UNSAFE ELECTRIC WIRING CONDITION CONSISTING OF EXPOSED ELECTRICA... | — | Jun 17, 2021 |
| May 13, 2021 | C | VIOLATION CLOSED | § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF REFRIGERATOR WITH DOORS ATTACHED AT PUBLIC HALL, 1s... | — | May 19, 2021 |
| Apr 13, 2021 | B | VIOLATION WILL BE REINSPECTED | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING IN THE 1st ... | 6 | May 18, 2021 |
| Apr 13, 2021 | B | VIOLATION WILL BE REINSPECTED | § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 6, 3rd STORY... | 6 | May 18, 2021 |
| Apr 13, 2021 | B | VIOLATION WILL BE REINSPECTED | § 27-2046.1, 2046.2 HMC: PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANC... | 6 | May 18, 2021 |
| Apr 13, 2021 | A | VIOLATION WILL BE REINSPECTED | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR ALL WALLS AND CEILI... | 6 | Jul 17, 2021 |
| Apr 13, 2021 | B | VIOLATION WILL BE REINSPECTED | § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE CERAMIC TILE AT EAST WALL IN THE BATHROOM LOCATED AT APT ... | 6 | May 18, 2021 |
| Apr 13, 2021 | A | VIOLATION WILL BE REINSPECTED | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE GROUTING ON ALL WALLS IN THE BATHROO... | 6 | Jul 17, 2021 |
| Apr 13, 2021 | A | VIOLATION WILL BE REINSPECTED | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CAULKING AROUND TUB IN THE BATHROOM ... | 6 | Jul 17, 2021 |
| Apr 13, 2021 | B | VIOLATION WILL BE REINSPECTED | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE ENTIRE APART... | 6 | May 18, 2021 |
| Mar 10, 2021 | A | VIOLATION CLOSED | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE CEILING, NORTH WALL IN T... | 4 | Jun 13, 2021 |
| Feb 8, 2021 | B | VIOLATION CLOSED | § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). DEFECTIVE IN THE ENTIRE APARTMENT LOCATED... | 4 | Mar 15, 2021 |
| Feb 8, 2021 | A | VIOLATION CLOSED | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT ALL PEELING PAINT SURFACES I... | 4 | May 14, 2021 |
| Feb 8, 2021 | B | VIOLATION CLOSED | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE BATHROOM LOC... | 4 | Mar 15, 2021 |
| Feb 8, 2021 | B | VIOLATION CLOSED | § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE FLOOR CERAMIC TILES IN THE KITCHEN LOCATED AT APT 4, 2nd ... | 4 | Mar 15, 2021 |
| Feb 8, 2021 | B | VIOLATION CLOSED | § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE GLASS PANE AT LOWER SASH AT FIRST WINDOW FROM EAST AT SOU... | 4 | Mar 15, 2021 |
| Feb 8, 2021 | A | VIOLATION CLOSED | § 27-2005 ADM CODE REFIT FIRST & SECOND WINDOW FRAMES FROM SOUTH AT WEST IN THE KITCHEN LOCATED AT APT 4, 2nd STORY, ... | 4 | May 14, 2021 |
| Feb 8, 2021 | C | VIOLATION DISMISSED | § 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) IN ACCORDANCE WITH THE SPECIFICAT... | 4 | Mar 6, 2021 |
| Feb 8, 2021 | B | VIOLATION CLOSED | § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 4, 2nd STORY... | 4 | Mar 15, 2021 |
| Feb 1, 2021 | C | VIOLATION CLOSED | § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PRESUMED LEAD PAINT THAT IS PEELING OR ON A DETERIORATED... | 4 | Feb 25, 2021 |
| Jan 29, 2021 | C | VIOLATION CLOSED | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 4, 2nd STOR... | 4 | Feb 24, 2021 |
| Jan 29, 2021 | C | VIOLATION DISMISSED | § 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) IN ACCORDANCE WITH THE SPECIFICAT... | 4 | Feb 24, 2021 |
| Aug 4, 2020 | B | VIOLATION CLOSED | § 27-2010, 2011, 2012 ADM CODE REMOVE THE ACCUMULATION OF REFUSE AND/OR RUBBISH AND MAINTAIN IN A CLEAN CONDITION THE... | — | Sep 8, 2020 |
| Aug 4, 2020 | B | FIRST NO ACCESS TO RE- INSPECT VIOLATION | § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF AIR CONDITIONER UNIT AND/OR BARS IN ALL WINDOWS IN ... | 2 | Sep 8, 2020 |
| Aug 4, 2020 | B | VIOLATION CLOSED | § 27-2005, 2007 ADM CODE REMOVE ALL ENCUMBRANCES CONSISTING OF BOXES AND BAGS OF CHARCOAL AT PUBLIC HALL, 1st STORY | — | Sep 8, 2020 |
| Aug 4, 2020 | C | DEFECT LETTER ISSUED | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 2, 1st STOR... | 2 | Aug 30, 2020 |
| — | I | VIOLATION DISMISSED | §27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE §27... | — | — |
| — | I | VIOLATION DISMISSED | §27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE §27... | — | — |
| Aug 17, 2018 | B | VIOLATION CLOSED | § 27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES... | — | Sep 21, 2018 |
| May 10, 2018 | B | VIOLATION CLOSED | § 27-2010, 2011, 2012 ADM CODE REMOVE THE ACCUMULATION OF REFUSE AND/OR RUBBISH AND MAINTAIN IN A CLEAN CONDITION THE... | — | Jun 14, 2018 |
| Sep 27, 2017 | B | VIOLATION CLOSED | § 27-2018 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF MICE LOCATED AT APT 5, 3rd STORY, 1st APARTMENT FROM WEST AT ... | 5 | Nov 1, 2017 |
| Sep 27, 2017 | B | VIOLATION CLOSED | § 27-2018 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF BEDBUGS LOCATED AT APT 5, 3rd STORY, 1st APARTMENT FROM WEST ... | 5 | Nov 1, 2017 |
| Sep 27, 2017 | B | VIOLATION CLOSED | § 27-2018 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF ROACHES LOCATED AT APT 5, 3rd STORY, 1st APARTMENT FROM WEST ... | 5 | Nov 1, 2017 |
| Sep 27, 2017 | B | VIOLATION CLOSED | § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE WINDOW PANE UPPER AND LOWER SASH AT WEST WALL IN THE 1st ... | 5 | Nov 1, 2017 |
| Sep 5, 2017 | B | VIOLATION CLOSED | § 27-2018 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 6, 3rd STORY, 1st... | 6 | Oct 10, 2017 |
| Sep 5, 2017 | B | VIOLATION CLOSED | § 27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES... | — | Oct 10, 2017 |
| Sep 5, 2017 | B | VIOLATION CLOSED | § 27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES... | — | Oct 10, 2017 |
| Sep 5, 2017 | B | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC FLOOR TILE IN THE KITCHEN LO... | 6 | Oct 10, 2017 |
| Sep 5, 2017 | B | VIOLATION CLOSED | § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). (DEFECTIVE) IN THE ENTIRE APARTMENT LOCAT... | 6 | Oct 10, 2017 |
| Sep 5, 2017 | B | VIOLATION CLOSED | § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR (DEFECTIVE) IN THE ENTIRE APARTMENT LOCATED AT APT 6, 3rd STO... | 6 | Oct 10, 2017 |
| Sep 5, 2017 | C | VIOLATION DISMISSED | § 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) IN ACCORDANCE WITH THE SPECIFICAT... | 6 | Oct 3, 2017 |