Maintenance code violations
14 East 96 Street, Brooklyn • Block 04598 • Lot 0016
122 records
HPD grades a violation A for non-hazardous through C for immediately hazardous.
| Issued | Class | Status | Violation | Apartment | Correct by |
|---|---|---|---|---|---|
| May 16, 2008 | B | FIRST NO ACCESS TO RE- INSPECT VIOLATION | D26-10.01 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE WINDOW GLASS REAR ROOM NORTH 4 STY APT 15. LOCATED AT APT 15 | 15 | Jun 20, 2008 |
| May 16, 2008 | A | FIRST NO ACCESS TO RE- INSPECT VIOLATION | D26-12.01 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT WALLS & CEILING THRU OUT 4 S... | 15 | Aug 19, 2008 |
| May 16, 2008 | A | FIRST NO ACCESS TO RE- INSPECT VIOLATION | D26-10.01 ADM CODE REFIT ENTRANCE DOOR 4 STY APT 15. LOCATED AT APT 15 | 15 | Aug 19, 2008 |
| May 16, 2008 | A | FIRST NO ACCESS TO RE- INSPECT VIOLATION | D26-10.01 ADM CODE REFIT ENTRANCE DOOR 4 STY APT 14. LOCATED AT APT 14 | 14 | Aug 19, 2008 |
| May 16, 2008 | B | FIRST NO ACCESS TO RE- INSPECT VIOLATION | D26-10.01 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC TILES FLOOR BATHROOM 4 STY A... | 14 | Jun 20, 2008 |
| May 16, 2008 | B | FIRST NO ACCESS TO RE- INSPECT VIOLATION | D26-10.01 ADM CODE REPLACE WITH NEW THE MISSING DOOR KNOB ALL ROOMS 4 STY APT 14. LOCATED AT APT 14 | 14 | Jun 20, 2008 |
| May 16, 2008 | B | FIRST NO ACCESS TO RE- INSPECT VIOLATION | D26-10.01 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE WINDOW GLASS LOWER SASH REAR NORTH ROOM 4 STY APT 14. LOC... | 14 | Jun 20, 2008 |
| May 16, 2008 | A | FIRST NO ACCESS TO RE- INSPECT VIOLATION | D26-12.01 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT WALLS & CEILING THRU OUT 4 S... | 14 | Aug 19, 2008 |
| May 16, 2008 | B | FIRST NO ACCESS TO RE- INSPECT VIOLATION | D26-10.01 ADM CODE REPLACE WITH NEW THE MISSING ELECTRIC CEILING LIGHT EXTERIOR VESTIBULE AND CENTER REAR APT 14 4 ST... | 14 | Jun 20, 2008 |
| May 16, 2008 | B | FIRST NO ACCESS TO RE- INSPECT VIOLATION | D26-10.01 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE ELECTRIC WALL SWITCH REAR NORTH EAST ROOM 2 STY APT B9. L... | B9 | Jun 20, 2008 |
| May 16, 2008 | B | FIRST NO ACCESS TO RE- INSPECT VIOLATION | D26-10.01 ADM CODE REPLACE WITH NEW THE MISSING ELECTRICAL CEILING FIXTURE ALL ROOMS 2 STY APTB5. LOCATED AT APT 5 | 5 | Jun 20, 2008 |
| May 16, 2008 | B | FIRST NO ACCESS TO RE- INSPECT VIOLATION | D26-10.01 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR WALL CENTER ROOM 2 ... | A8 | Jun 20, 2008 |
| May 16, 2008 | B | FIRST NO ACCESS TO RE- INSPECT VIOLATION | D26-10.01 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE ELECTRICAL LIGHT SWITCH WALL CENTER ROOM 2 STY APT A8. LO... | A8 | Jun 20, 2008 |
| May 16, 2008 | B | FIRST NO ACCESS TO RE- INSPECT VIOLATION | D26-10.01 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE ELECTRIC WALL OUTLET CENTER ROOM 2 STY APT A8. LOCATED AT... | A8 | Jun 20, 2008 |
| May 16, 2008 | B | FIRST NO ACCESS TO RE- INSPECT VIOLATION | D26-10.01 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE WINDOW GLASS TOP SASH WEST ROOM 2 STY APT A8. LOCATED AT ... | A8 | Jun 20, 2008 |
| May 16, 2008 | B | VIOLATION CLOSED | D26-10.01, 10.05 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPE... | — | Jun 20, 2008 |
| May 16, 2008 | B | VIOLATION CLOSED | D26-10.01, 10.05 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPE... | — | Jun 20, 2008 |
| May 16, 2008 | B | FIRST NO ACCESS TO RE- INSPECT VIOLATION | D26-16.01 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS BATHTUB 2 STY APT A6 BATROOMS. LOCATED AT APT A6 | A6 | Jun 20, 2008 |
| May 16, 2008 | C | FIRST NO ACCESS TO RE- INSPECT VIOLATION | D26-17.07 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES KITCHEN & BATHROOM 1 STY APT B1 ER1.. , SECTION '' '' | B1 | May 22, 2008 |
| May 16, 2008 | A | FIRST NO ACCESS TO RE- INSPECT VIOLATION | D26-20.05 ADM CODE PROVIDE A LOCK AND KEY TO THE ENTRANCE DOOR OF DWELLING UNIT AND, IF A CL A MULTIPLE DWELLING, ALS... | A6 | Aug 19, 2008 |
| May 16, 2008 | A | FIRST NO ACCESS TO RE- INSPECT VIOLATION | D26-20.05 ADM CODE PROVIDE A LOCK AND KEY TO THE ENTRANCE DOOR OF DWELLING UNIT AND, IF A CL A MULTIPLE DWELLING, ALS... | A10 | Aug 19, 2008 |
| May 16, 2008 | A | NOT COMPLIED WITH | D26-10.01 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE PLASTER BOARD CEILING CELLAR AT SOUTH. | — | Aug 19, 2008 |
| May 16, 2008 | A | NOT COMPLIED WITH | D26-10.01 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE ALL CONCRETE TREADS & RISERS OF STAI... | — | Aug 19, 2008 |
| May 16, 2008 | A | FIRST NO ACCESS TO RE- INSPECT VIOLATION | D26-10.01 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR WALLS & CEILINGS OF... | A3 | Aug 19, 2008 |
| May 16, 2008 | A | FIRST NO ACCESS TO RE- INSPECT VIOLATION | D26-16.01 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS BATH TUB & BASIN IN BATHRM & SINK IN KITCHEN 1 STY APT A... | A3 | Aug 19, 2008 |
| May 16, 2008 | B | FIRST NO ACCESS TO RE- INSPECT VIOLATION | D26-16.01 ADM CODE REMOVE ALL OBSTRUCTIONS AND REPAIR ALL DEFECTS IN BATH TUB & BASIN BATHRM 1 STY APT A3. LOCATED AT... | A3 | Jun 20, 2008 |
| May 16, 2008 | A | FIRST NO ACCESS TO RE- INSPECT VIOLATION | D26-10.01 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE MARBLE DOOR SADDLE ENTRANCE DOOR TO 4 STY APT B16. LOCATE... | B16 | Aug 19, 2008 |
| May 16, 2008 | A | FIRST NO ACCESS TO RE- INSPECT VIOLATION | D26-12.01 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT WALLS & CEILING OF BATHRM 3 ... | B8 | Aug 19, 2008 |
| May 16, 2008 | A | FIRST NO ACCESS TO RE- INSPECT VIOLATION | D26-12.01 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT WALLS & CEILING OF BATHRM 3 ... | B8 | Aug 19, 2008 |
| May 16, 2008 | A | FIRST NO ACCESS TO RE- INSPECT VIOLATION | D26-10.01 ADM CODE PROPERLY SECURE THE LOOSE CEILING LIGHT FIXTURE BATHRM 3 STY APT B14. LOCATED AT APT B14 | B14 | Aug 19, 2008 |
| May 16, 2008 | A | FIRST NO ACCESS TO RE- INSPECT VIOLATION | D26-10.01 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING OF BATHRM 3... | B14 | Aug 19, 2008 |
| May 16, 2008 | B | FIRST NO ACCESS TO RE- INSPECT VIOLATION | D26-10.01, 10.05 ADM CODE FIRE EGRESS DEFECTIVE. REMOVE OBSTRUCTING BARS OR UNLAWFUL GATES FROM WINDOW TO FIRE ESCAPE... | B14 | Jun 20, 2008 |
| May 16, 2008 | A | FIRST NO ACCESS TO RE- INSPECT VIOLATION | D26-10.01 ADM CODE REPLACE WITH NEW THE MISSING ELEC LIGHT FIXTURE OF CNTR RM 3 STY APT B14. LOCATED AT APT B14 | B14 | Aug 19, 2008 |
| May 16, 2008 | A | FIRST NO ACCESS TO RE- INSPECT VIOLATION | D26-10.01 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE BUZZER 1ST STY PUBLIC VESTIBULE TO 1ST STY REAR NORTH APT ... | 1B | Aug 19, 2008 |
| May 16, 2008 | B | FIRST NO ACCESS TO RE- INSPECT VIOLATION | D26-10.01, 10.05 ADM CODE FIRE EGRESS DEFECTIVE. REMOVE OBSTRUCTING BARS OR UNLAWFUL GATES FROM WINDOW TO FIRE ESCAPE... | B16 | Jun 20, 2008 |
| May 16, 2008 | A | FIRST NO ACCESS TO RE- INSPECT VIOLATION | D26-10.01 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE ELECTRIC WALL OUTLET REAR ROOM 2ND STY NORTH APT B9. , SEC... | B9 | Aug 19, 2008 |
| May 16, 2008 | B | NOT COMPLIED WITH | D26-10.01 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING AT BULKHEAD... | — | Jun 20, 2008 |
| May 16, 2008 | A | FIRST NO ACCESS TO RE- INSPECT VIOLATION | D26-10.01 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING & WALLS KIT... | 7 | Aug 19, 2008 |
| May 16, 2008 | A | FIRST NO ACCESS TO RE- INSPECT VIOLATION | D26-16.01 ADM CODE REPAIR LEAKY WATER CLOSET FLUSH PIPE CONNECTION WATER CLOSET BATHROOM 1 STY APT 1B. , SECTION '' '' | 1B | Aug 19, 2008 |
| May 16, 2008 | A | FIRST NO ACCESS TO RE- INSPECT VIOLATION | D26-10.01 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING BATHROOM 1 ... | 1B | Aug 19, 2008 |
| May 16, 2008 | C | FIRST NO ACCESS TO RE- INSPECT VIOLATION | D26-17.07 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES KITCHEN & BATHROOM 3RD STY FRONT APT A10 FRONT WING. L... | A10 | May 22, 2008 |
| May 16, 2008 | A | FIRST NO ACCESS TO RE- INSPECT VIOLATION | D26-12.01 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT CEILINGS OF ALLROOMS 4 STY A... | A18 | Aug 19, 2008 |
| May 16, 2008 | A | FIRST NO ACCESS TO RE- INSPECT VIOLATION | D26-16.01 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS KITCHEN SINK 1ST STY SOUTH APT A3. , SECTION '' '' | A3 | Aug 19, 2008 |
| May 16, 2008 | C | FIRST NO ACCESS TO RE- INSPECT VIOLATION | D26-16.01 ADM CODE REPAIR THE FLUSHING APPARATUS AND MAINTAIN SAME SO AS TO FLUSH EFFECTIVELY THE WATER CLOSET BATHRO... | A3 | May 22, 2008 |
| May 16, 2008 | A | FIRST NO ACCESS TO RE- INSPECT VIOLATION | D26-16.01 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS KITCHEN SINK 1ST STY SOUTH APT A3. , SECTION '' '' | A3 | Aug 19, 2008 |
| May 16, 2008 | C | FIRST NO ACCESS TO RE- INSPECT VIOLATION | D26-16.01 ADM CODE REPAIR THE FLUSHING APPARATUS AND MAINTAIN SAME SO AS TO FLUSH EFFECTIVELY THE WATER CLOSET BATHRO... | A3 | May 22, 2008 |
| May 16, 2008 | B | VIOLATION CLOSED | D26-10.01 ADM CODE ABATE THE NUISANCE CONSISTING OF DOUBLE CYLINDER LOCKS APT ENTRY DOOR 1ST STY FRONT SOUTH APT A4 E... | — | Jun 20, 2008 |
| May 16, 2008 | B | FIRST NO ACCESS TO RE- INSPECT VIOLATION | D26-17.07 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES 1ST STY APT 3A. , SECTION '' '' | 3A | Jun 20, 2008 |
| May 16, 2008 | A | FIRST NO ACCESS TO RE- INSPECT VIOLATION | D26-10.01 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR WALLS & CEILINGS OF... | 3A | Aug 19, 2008 |
| May 16, 2008 | A | FIRST NO ACCESS TO RE- INSPECT VIOLATION | D26-16.01 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT KITCHEN SINK 1ST STY APT 3A. , SECTION '' '' | 3A | Aug 19, 2008 |