ECB violations
30 East 98 Street, Brooklyn • Block 04600 • Lot 0017
17 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Sep 15, 2025 | 39160423H | RESOLVE | CLASS - 2 | OBSERVED ON THE 4TH FLOOR, HOT WATER HEATER VENT IS BACK PITCHED, AND IN THE BASEMENT THERE IS NO P TRAP UNDER THE SI... | $0 | $0 | Dec 17, 2025 |
| Oct 9, 2024 | 39126999L | RESOLVE | CLASS - 2 | EXIT DOOR NOT SELF-CLOSING. OBSERVED NON-SELF-CLOSING DOORS ON ROOF LEVEL AND 1ST FLOOR LEADING TO REAR YARD. (MISSIN... | $312 | $0 | Jun 6, 2025 |
| Oct 9, 2024 | 39127023Y | RESOLVE | CLASS - 1 | I OBSERVED ON ALL FLOORS THE FAILURE TO INSTALL TAMPER-RESISTANT OUTLETS AS REQUIRED FOR COMMONS AREAS ACCESSIBLE TO ... | $2,500 | $2,500 | Jun 27, 2025 |
| Oct 9, 2024 | 39126998J | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER: NO FIRE STOPPING PER BC 712.3 (2014 CODE); 27-345; BC 711.2.4 ... | $2,500 | $0 | Jun 6, 2025 |
| Oct 9, 2024 | 39127022M | RESOLVE | CLASS - 1 | I OBSERVED IN THE MAIN ELECTRICAL ROOM THE INSTALLATION OF THE SERVICE DISCONNECT FOR THE EMERGENCY GENERATOR. AS PER... | $1,600 | $1,600 | Dec 18, 2024 |
| Oct 9, 2024 | 39126991R | RESOLVE | CLASS - 2 | NO EXTRA SPRINKLER HEADS ON SITE AT THE TIME OF MY INSPECTION. AS PER 903.5 OF THE FIRE CODE, THERE SHALL BE KEPT AVA... | $312 | $312 | Jun 24, 2025 |
| Feb 11, 2021 | 35543967Z | RESOLVE | CLASS - 1 | BC3309.10 PROTECTION OF ROOFS.NOTE-@TIME OF INSP I OBSERVED INADEQUATEROOF PROTECTION@EXP2 NOT SECURED&VENT WAS EXPOS... | $2,500 | $0 | Jun 23, 2021 |
| Feb 11, 2021 | 35543965P | RESOLVE | CLASS - 2 | WORK DOESN'T CONFORM TO APPROVED CONST DOCS &/OR APPROVED AMENDMENTS.NOTE-@TIME OF INSP UPON REV OF SIDEWALK SHED DRA... | $0 | $0 | Jun 23, 2021 |
| Feb 11, 2021 | 35543963L | RESOLVE | CLASS - 1 | PERMIT HOLDER FAILED TO ENSURE WORKERS RECIEVE SITE SAFETY ORIENTATION.NOTE-@TIME OF INSP I OBSERVED 2WORKERS ONSITE ... | $5,000 | $0 | Jun 23, 2021 |
| Feb 11, 2021 | 35543964N | RESOLVE | CLASS - 1 | BC3315.2 PLATFORMS.NOTE-@TIME OF INSP I OBSERVED PLATFORM ERECTED IN STAIRWELL NOT SECURED,PLANKS WERE RESTING ON LAD... | $2,500 | $0 | Jun 23, 2021 |
| Feb 11, 2021 | 35543966R | RESOLVE | CLASS - 2 | BC3314.1 UNSAFE SUPPORTED SCAFFOLD.NOTE@TIME OF INSP I OBSERVED SUPPORTED PIPE SCAFFOLD IN PLACE (1)FAILURE TO MAINTA... | $625 | $0 | Jun 23, 2021 |
| Jul 25, 2020 | 35491401H | RESOLVE | CLASS - 1 | HANDRAILS. NOTE: AT TIME OF MY INSPECTION OF A 4 STY BLDG AT 3 STY SRAGE CONSTRUCTION WORK IN PROGRESS. I OBSERVED TH... | $2,500 | $0 | May 17, 2021 |
| Jul 25, 2020 | 35491402J | RESOLVE | CLASS - 1 | SEC. 3301.7 DESIGN DRAWING. NOTE: AT TIME OF MY INSPECTION OF A 4 STY BLDG AT 3 STY STAGE CONSTRUCTION WORK IN PROGRE... | $1,250 | $0 | May 17, 2021 |
| Jul 25, 2020 | 35491400X | RESOLVE | CLASS - 2 | FAILURE TO INSTITUTE/MAINTAIN SAFETY EQUIPMENT MEASURES OR TEMPORARY CONSTRUCTION-NO OVERHEAD PROTECTION. NOTE: AT TI... | $5,000 | $0 | May 17, 2021 |
| Aug 14, 2019 | 35441187K | RESOLVE | CLASS - 2 | INADEQUATE VIEWING PANELS IN JOB SITE FENCE. NOTED: AT THE TIME OF MY INSPECTION,I OBSERVED A CONSTRUCTION FENCE AT E... | $0 | $0 | Dec 16, 2019 |
| Jul 25, 2019 | 35444333N | RESOLVE | CLASS - 1 | NO APPROVE PLAN ON SITE FOR DEMO WORK. AT TIME OF INSPECTION ON AN ACTIVE CONSTRUCTION SITE IN DEMO PHASE,NOTICE WORK... | $625 | $0 | Nov 25, 2019 |
| Jul 25, 2019 | 35444334P | RESOLVE | CLASS - 1 | MISSING GUARD RAILS AROUND OPENINGS. AT TIME OF INSPECTION ON AN ACTIVE CONSTRUCTION SITE IN DEMO PHASE,NOTICE WORK(D... | $2,500 | $0 | Nov 25, 2019 |