126 East 93 Street, Brooklyn • Block 04611 • Lot 0013
282 records
HPD grades a violation A for non-hazardous through C for immediately hazardous.
| Issued | Class | Status | Violation | Apartment | Correct by |
|---|---|---|---|---|---|
| Oct 5, 2020 | C | VIOLATION DISMISSED | § 27-2037, 2038 HMC: PROVIDE A SAFE AND ADEQUATE SUPPLY OF ELECTRIC SERVICE TO THE FIXTURES AT CEILING AND ALL ELECTR... | 1F | Oct 11, 2020 |
| Dec 6, 2019 | C | VIOLATION CLOSED | § 27-2005 ADM CODE REPLACE WITH NEW THE MISSING 6 BALUSTERS AT PUBLIC HALL BULKHEAD STAIRS | — | Dec 14, 2019 |
| Dec 6, 2019 | B | VIOLATION CLOSED | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... WALLS AND CEILING APPROX 300 SQ.... | — | Jan 10, 2020 |
| Dec 6, 2019 | C | VIOLATION CLOSED | § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF FREE STANDING RADIATOR AT PUBLIC HALL, 1st STORY | — | Dec 14, 2019 |
| Dec 6, 2019 | B | VIOLATION DISMISSED | § 27-2010, 2011, 2012 ADM CODE CLEANSE AND DISINFECT TO THE SATISFACTION OF THIS DEPARTMENT AFTER REMOVING THE RAW SE... | — | Jan 10, 2020 |
| Nov 19, 2018 | B | VIOLATION CLOSED | § 27-2005, 2007 ADM CODE REMOVE ALL ENCUMBRANCES CONSISTING OF HOUSEHOLD ITEMS AT PUBLIC HALL, 2nd STORY | — | Dec 24, 2018 |
| Nov 19, 2018 | C | VIOLATION CLOSED | § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF DISCARDED RADIATOR AT PUBLIC HALL, 2nd STORY | — | Nov 27, 2018 |
| — | I | VIOLATION DISMISSED | §27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE §27... | — | — |
| Jul 18, 2018 | B | VIOLATION CLOSED | § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 2F, 2nd STORY,... | 2F | Aug 22, 2018 |
| Jul 18, 2018 | B | VIOLATION CLOSED | § 27-2026 ADM CODE REPAIR THE BROKEN OR DEFECTIVE CONNECTION SINK WASTE DRAIN PIPE IN THE KITCHEN LOCATED AT APT 2F, ... | 2F | Aug 22, 2018 |
| Jul 18, 2018 | B | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC TILES AT FLOOR IN THE 2nd RO... | 2F | Aug 22, 2018 |
| Jul 18, 2018 | B | VIOLATION CLOSED | § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). DEFECTIVE IN THE ENTIRE APARTMENT LOCATED... | 1F | Aug 22, 2018 |
| Jul 18, 2018 | B | VIOLATION CLOSED | § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 1F, 1st STOR... | 1F | Aug 22, 2018 |
| Jul 18, 2018 | B | VIOLATION CLOSED | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING IN THE ... | 1R | Aug 22, 2018 |
| Jul 18, 2018 | B | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOODEN DOOR IN THE 1st ROOM FROM EAS... | 2F | Aug 22, 2018 |
| Jul 18, 2018 | B | VIOLATION CLOSED | § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING IN THE ENTIRE APARTMENT LOCATED A... | 2F | Aug 22, 2018 |
| Jul 18, 2018 | B | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOODEN DOOR IN THE 1st ROOM FROM EAS... | 2F | Aug 22, 2018 |
| Mar 27, 2018 | C | VIOLATION CLOSED | § 27-2029 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF HEAT FOR THE APARTMENT IN THE ENTIRE APARTMENT LOCATED AT APT 2R, 2n... | 2R | Mar 24, 2018 |
| Mar 27, 2018 | C | VIOLATION DISMISSED | § 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM LOCKED AT BOILER | 2R | Apr 4, 2018 |
| Jan 24, 2017 | B | VIOLATION CLOSED | § 27-2005 ADM CODE REPLACE WITH NEW THE MISSING BUILDING FRONT ENTRANCE DOOR | — | Feb 28, 2017 |
| Jan 19, 2017 | B | VIOLATION CLOSED | § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 2R, 2nd STORY,... | 2R | Feb 23, 2017 |
| Jan 19, 2017 | C | VIOLATION CLOSED | § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF REFRIGERATOR WITH DOOR INTACT AT PUBLIC HALL, 2nd S... | — | Jan 27, 2017 |
| Jan 19, 2017 | B | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR IN THE KITCHEN LOCATED AT... | 2R | Feb 23, 2017 |
| Jan 19, 2017 | C | VIOLATION CLOSED | § 27-2037, 2038 HMC: PROVIDE A SAFE AND ADEQUATE SUPPLY OF ELECTRIC SERVICE TO THE FIXTURES .. IN THE ENTIRE APARTMEN... | 2R | Jan 27, 2017 |
| Jan 19, 2017 | B | VIOLATION CLOSED | § 27-2046.1, 2046.2 HMC: PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANC... | 2R | Feb 23, 2017 |
| Jan 19, 2017 | B | VIOLATION CLOSED | § 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES GAS STOVE. IN THE KITCHEN LOCATED AT APT 2R, 2nd... | 2R | Feb 23, 2017 |
| Jan 19, 2017 | C | VIOLATION CLOSED | § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 2R, 2nd STORY, ... | 2R | Jan 18, 2017 |
| Jan 10, 2017 | C | VIOLATION CLOSED | § 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES AT GAS RANGE IN THE KITCHEN LOCATED AT APT 2R, 2... | 2R | Jan 18, 2017 |
| Jan 10, 2017 | C | VIOLATION CLOSED | § 27-2037, 2038 HMC: PROVIDE A SAFE AND ADEQUATE SUPPLY OF ELECTRIC SERVICE TO THE FIXTURES .. IN THE ENTIRE APARTMEN... | 2R | Jan 18, 2017 |
| Jan 10, 2017 | C | VIOLATION CLOSED | § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 2R, 2nd STORY, ... | 2R | Jan 7, 2017 |
| Jan 10, 2017 | B | VIOLATION CLOSED | § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING LOCATED AT APT 2R, 2nd STORY, 1st APARTMENT FROM SOUT... | 2R | Feb 14, 2017 |
| Jan 10, 2017 | B | VIOLATION CLOSED | § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING LOCATED AT APT 2R, 2nd STORY, 1st... | 2R | Feb 14, 2017 |
| Jan 9, 2017 | B | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE BOTTOM WINDOW SASH IN THE KITCHEN LOCATED AT APT 2R, 2nd S... | 2R | Feb 13, 2017 |
| Jan 9, 2017 | B | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE CERAMIC WALL TILE IN THE BATHROOM LOCATED AT APT 2R, 2nd S... | 2R | Feb 13, 2017 |
| Jan 9, 2017 | B | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE VINYL TILE FLOORING IN THE 1st ROOM ... | 2R | Feb 13, 2017 |
| Jan 9, 2017 | B | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY SECURE THE LOOSE SINK IN THE BATHROOM LOCATED AT APT 2R, 2nd STORY, 1st APARTMENT FROM EA... | 2R | Feb 13, 2017 |
| Jan 6, 2017 | B | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC TILE AT SOUTH WALL IN THE BA... | 2R | Feb 10, 2017 |
| Jan 6, 2017 | B | VIOLATION DISMISSED | § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE DOOR LOCK IN THE KITCHEN LOCATED AT APT 2R, 2nd STORY, 1s... | 2R | Feb 10, 2017 |
| Jan 6, 2017 | B | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY SECURE THE LOOSE UPPER CABINET AT WEST WALL IN THE KITCHEN LOCATED AT APT 2R, 2nd STORY, ... | 2R | Feb 10, 2017 |
| Jan 6, 2017 | B | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOORING IN THE 1st ROOM FROM N... | 2R | Feb 10, 2017 |
| Jan 6, 2017 | B | VIOLATION CLOSED | § 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES AT GAS RANGE IN THE KITCHEN LOCATED AT APT 2R, 2... | 2R | Feb 10, 2017 |
| Jan 6, 2017 | B | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE BOTTOM SASH WINDOW IN THE KITCHEN LOCATED AT APT 2R, 2nd S... | 2R | Feb 10, 2017 |
| Jan 6, 2017 | B | VIOLATION CLOSED | § 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS SINK IN THE BATHROOM LOCATED AT APT 2R, 2nd STORY, APART... | 2R | Feb 10, 2017 |
| Jan 6, 2017 | B | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE BOTTOM SASH WINDOW IN THE 1st ROOM FROM NORTH AT EAST LOCA... | 2R | Feb 10, 2017 |
| Jan 6, 2017 | B | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC WALL TILE IN THE KITCHEN LOC... | 2R | Feb 10, 2017 |
| Jan 6, 2017 | B | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE RADIATOR IN THE 1st ROOM FROM NORTH AT EAST LOCATED AT APT... | 2R | Feb 10, 2017 |
| Jan 6, 2017 | B | VIOLATION CLOSED | § 27-2005 HMC:TRACE AND REPAIR THE SOURCE AND ABATE THE NUISANCE CONSISTING OF MOLD ... CEILING IN THE BATHROOM FROM ... | 2R | Feb 10, 2017 |
| Jan 6, 2017 | B | VIOLATION CLOSED | § 27-2037, 2038 HMC: PROVIDE A SAFE AND ADEQUATE SUPPLY OF ELECTRIC SERVICE TO THE FIXTURES CEILING LIGHT FIXTURE AND... | 2R | Feb 10, 2017 |
| Jan 6, 2017 | B | VIOLATION CLOSED | § 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS SINK IN THE KITCHEN LOCATED AT APT 2R, 2nd STORY, 1st AP... | 2R | Feb 10, 2017 |
| Jan 6, 2017 | B | VIOLATION CLOSED | § 27-2037, 2038 HMC: PROVIDE A SAFE AND ADEQUATE SUPPLY OF ELECTRIC SERVICE TO THE FIXTURES CEILING LIGHT FIXTURES AN... | 2R | Feb 10, 2017 |