Maintenance code violations

356 Maple Street, Brooklyn • Block 04796 • Lot 0030

341 records

HPD grades a violation A for non-hazardous through C for immediately hazardous.

Issued Class Status Violation Apartment Correct by
Jul 31, 2026 C NOTICE OF ISSUANCE SENT TO TENANT § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... GREATER THAN 10 SQ FEET OBSERVED... D1 Aug 26, 2026
Jun 1, 2026 A VIOLATION CLOSED § 27-2005 ADM CODE PAINT METAL IN ACCORDANCE WITH DEPT. REGULATION THE RISER AT WEST IN THE BATHROOM LOCATED AT APT D... D6 Sep 4, 2026
Jun 1, 2026 A VIOLATION CLOSED § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10 SQ.FT AT NORTH WALL... D6 Sep 4, 2026
Jun 1, 2026 B VIOLATION CLOSED § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... GREATER THAN 10 SQ FEET OBSERVED... D1 Jul 6, 2026
Jun 1, 2026 B VIOLATION CLOSED § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE COUNTER BALANCE AT LOWER WINDOW SASH AT NORTH WALL ... B9 Jul 6, 2026
Jun 1, 2026 B VIOLATION CLOSED § 27-2005 ADM CODE REPLACE WITH NEW THE MISSING CERAMIC WALL TILES AT EAST AND NORTH WALLS IN THE BATHROOM LOCATED AT... D6 Jul 6, 2026
Jun 1, 2026 C NOT COMPLIED WITH HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT D6, 4th STO... D6 Jun 27, 2026
Jun 1, 2026 A VIOLATION CLOSED § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT ALL WALLS IN THE BATHROOM LO... D6 Sep 4, 2026
Jun 1, 2026 C NOT COMPLIED WITH HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT D6, 4th ... D6 Jun 27, 2026
May 18, 2026 B VIOLATION CLOSED § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE VINYL FLOOR TILES IN THE 2nd ROOM FR... 9B Jun 22, 2026
May 18, 2026 B VIOLATION CLOSED § 27-2005, 2007 ADM CODE FIRE EGRESS DEFECTIVE. REMOVE THE OBSTRUCTION IN FIREPROOF PASSAGEWAY AT REAR YARD YARD Jun 22, 2026
May 18, 2026 B VIOLATION CLOSED § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE 4th ROOM FRO... D1 Jun 22, 2026
May 18, 2026 B VIOLATION CLOSED § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE BASE CABINET DOOR AT SOUTH WALL IN THE KITCHEN LOCA... D1 Jun 22, 2026
May 18, 2026 B VIOLATION CLOSED § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE 2nd ROOM FRO... D1 Jun 22, 2026
May 18, 2026 C VIOLATION CLOSED § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE 4... D1 May 24, 2026
May 18, 2026 B FIRST NO ACCESS TO RE- INSPECT VIOLATION § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE GAPPING WOOD FLOORING IN THE 4th ROO... A6 Jun 22, 2026
May 18, 2026 A VIOLATION CLOSED § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE CEILING AND ALL WALLS IN... 9B Aug 21, 2026
May 18, 2026 A VIOLATION WILL BE REINSPECTED §27-2104(B) HMC POST A PROPER NOTICE REGARDING RENT STABILIZATION LAW, IN A FORM APPROVED BY THE COMMISSIONER, IN A C... Aug 21, 2026
May 18, 2026 B VIOLATION CLOSED § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE PAVING AT THE CENTER COURT Jun 22, 2026
May 18, 2026 B FIRST NO ACCESS TO RE- INSPECT VIOLATION § 27-2005 ADM CODE PROVIDE ESCUTCHEON PLATE AT RISER AT CEILING IN THE KITCHEN LOCATED AT APT A6, 1st STORY, 2nd APAR... A6 Jun 22, 2026
May 18, 2026 B VIOLATION CLOSED § 27-2010, 2011, 2012 ADM CODE REMOVE THE ACCUMULATION OF REFUSE AND/OR RUBBISH AND MAINTAIN IN A CLEAN CONDITION THE... Jun 22, 2026
May 18, 2026 B VIOLATION CLOSED § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD SUB FLOOR AT RADIATOR IN THE 2n... 9B Jun 22, 2026
May 18, 2026 A VIOLATION CLOSED § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10 SQUARE FEET AT SOUT... D1 Aug 21, 2026
May 18, 2026 B VIOLATION CLOSED § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE BASE MOULDING AT NORTH WALL IN THE 5th ROOM FROM EA... D1 Jun 22, 2026
May 8, 2026 C VIOLATION CLOSED § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE 4... D1 May 14, 2026
May 8, 2026 B VIOLATION CLOSED § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE 2... D1 Jun 12, 2026
May 8, 2026 B VIOLATION CLOSED § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE 4th ROOM FRO... D1 Jun 12, 2026
May 8, 2026 A NOT COMPLIED WITH § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10 SQUARE FEET AT SOUT... D1 Aug 11, 2026
Apr 28, 2026 B VIOLATION CLOSED § 27-2005 ADM CODE PROPERLY SECURE THE LOOSE SHIFTING COUNTER TOP AT NORTH WALL IN THE KITCHEN LOCATED AT APT 7C, 3rd... 7C Jun 2, 2026
Apr 28, 2026 B VIOLATION CLOSED § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE AND CRACKED CERAMIC FLOOR TILES IN T... 7C Jun 2, 2026
Apr 28, 2026 B VIOLATION CLOSED § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE B... 7C Jun 2, 2026
Apr 28, 2026 C VIOLATION CLOSED § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE SPRING COUNTER BALANCES AT LOWER SASH WINDOW AT SOU... 7C May 4, 2026
Apr 28, 2026 B VIOLATION CLOSED § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE CEILING LIGHT FIXTURE IN THE BATHROOM LOCATED AT AP... 7C Jun 2, 2026
Apr 28, 2026 B VIOLATION CLOSED § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE BATHROOM LOC... 7C Jun 2, 2026
Apr 28, 2026 B VIOLATION CLOSED § 27-2021 ADM CODE PROVIDE SUFFICIENT, PROPER AND SEPARATE METAL RECEPTACLES FOR THE DEPOSIT OF GARBAGE, RUBBISH AND ... Jun 2, 2026
Apr 28, 2026 A VIOLATION WILL BE REINSPECTED §27-2104(B) HMC POST A PROPER NOTICE REGARDING RENT STABILIZATION LAW, IN A FORM APPROVED BY THE COMMISSIONER, IN A C... Aug 1, 2026
Apr 28, 2026 B VIOLATION CLOSED § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE SURFACE AT WINDOW STOOL IN THE 1st R... 7C Jun 2, 2026
Apr 28, 2026 B VIOLATION CLOSED § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE STONE AND MORTAR SURFACES AT THE PIL... Jun 2, 2026
Apr 28, 2026 B VIOLATION CLOSED § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CONCRETE RETAINING WALL AT LOT LINE ... Jun 2, 2026
Apr 28, 2026 B VIOLATION CLOSED § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE 1... 7C Jun 2, 2026
Apr 28, 2026 C VIOLATION CLOSED § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE SPRING COUNTER BALANCES AT LOWER SASH WINDOW AT SOU... 7C May 4, 2026
Apr 28, 2026 B VIOLATION CLOSED § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE 1st ROOM FRO... 7C Jun 2, 2026
Apr 27, 2026 A VIOLATION CLOSED § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE CEILING AND ALL WALLS IN... 3D Jul 31, 2026
Apr 27, 2026 C VIOLATION CLOSED § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE SPRING COUNTER BALANCES AT LOWER SASH WINDOW AT NOR... 3D May 3, 2026
Apr 27, 2026 C VIOLATION CLOSED § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE SPRING COUNTER BALANCES AT FIRE ESCAPE WINDOW LOWER... 3D May 3, 2026
Apr 27, 2026 B VIOLATION CLOSED § 27-2005, 2006, 2037 HMC: PROPERLY REPAIR AND ABATE UNSAFE ELECTRIC WIRING CONDITION CONSISTING OF EXPOSED WIRES AT ... 3D Jun 1, 2026
Apr 27, 2026 B VIOLATION CLOSED § 27-2026 ADM CODE REPAIR THE FLUSHING APPARATUS AND MAINTAIN SAME SO AS TO FLUSH EFFECTIVELY THE WATER CLOSET IN THE... 3D Jun 1, 2026
Apr 27, 2026 B VIOLATION CLOSED § 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT BATHTUB IN THE BATHROOM LOCATED AT APT 3D, 4th STORY,... 3D Jun 1, 2026
Apr 27, 2026 B VIOLATION CLOSED § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE CEILING LIGHT FIXTURE IN THE 3rd ROOM FROM EAST LOC... 3D Jun 1, 2026
Apr 27, 2026 B VIOLATION CLOSED § 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING ... 3D Jun 1, 2026