Maintenance code violations
237 East 35 Street, Brooklyn • Block 04889 • Lot 0042
68 records
HPD grades a violation A for non-hazardous through C for immediately hazardous.
| Issued | Class | Status | Violation | Apartment | Correct by |
|---|---|---|---|---|---|
| Jul 3, 2006 | B | NOV SENT OUT | SECTION 27-2005 ADMIN. CODE: PROPERLY REPAIR THE BROKEN OR DEFECTIVE FRONT ENTRANCE DOOR JAMB TO BLDG, 1ST STORY LOCK... | — | Aug 19, 2006 |
| Jul 3, 2006 | B | NOV SENT OUT | SECTION 27-2005 ADMIN. CODE: REPLACE WITH NEW THE MISSING ELECTRICAL CEILING LIGHT FIXTURES, 2ND STORY DUPLEX THROUGHOUT | — | Aug 19, 2006 |
| Jul 3, 2006 | B | NOV SENT OUT | SECTION 27-2005 ADMIN. CODE: REPLACE WITH NEW THE MISSING CELLAR WINDOW AT REAR | — | Aug 19, 2006 |
| Jul 3, 2006 | B | NOV SENT OUT | SECTION 27-2005 ADMIN. CODE: REPLACE WITH NEW THE BROKEN OR DEFECTIVE GLASS FRONT CELLAR WINDOW | — | Aug 19, 2006 |
| Jul 3, 2006 | B | NOV SENT OUT | SECTION 27-2005 ADMIN. CODE: PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CELOTEX CELLAR CEILING THR... | — | Aug 19, 2006 |
| Jul 3, 2006 | B | NOV SENT OUT | SECTION 27-2010,2011,2012 ADMIN. CODE: CLEANSE AND DISINFECT TO THE SATISFACTION OF THIS DEPARTMENT AFTER REMOVING TH... | — | Aug 19, 2006 |
| Jul 3, 2006 | C | NOV SENT OUT | SECTION 27-2005 ADMIN. CODE: REPAIR THE ROOF SO THAT IT WILL NOT LEAK OVER 2ND STORYTHROUGHOUT | — | Jul 21, 2006 |
| Jul 3, 2006 | A | NOV SENT OUT | SECTION 27-2005 ADMIN. CODE: REPLACE WITH NEW THE MISSING STRIKER PLATE LOCK SIDE FRONT ENTRANCE DOOR TO BLDG | — | Oct 18, 2006 |
| Jul 3, 2006 | B | NOV SENT OUT | SECTION 27-2005 ADMIN. CODE: PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE PLASTER BOARD CEILING, KIT... | — | Aug 19, 2006 |
| Jul 3, 2006 | B | NOV SENT OUT | SECTION 27-2005 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF EXPOSED ELECTRICAL WIRES CEILINGS, KITCHEN AND REAR ROO... | — | Aug 19, 2006 |
| Jul 3, 2006 | B | NOV SENT OUT | SECTION 27-2005 ADMIN. CODE: PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE PLASTER BOARD CEILING REAR... | — | Aug 19, 2006 |
| Jul 3, 2006 | B | NOV SENT OUT | SECTION 27-2005 ADMIN. CODE: REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN UNIFORM COLOR CEILING FRO... | — | Aug 19, 2006 |
| Jul 3, 2006 | B | NOV SENT OUT | SECTION 27-2005 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF EXPOSED ELECTRICAL WIRES SWITCH BOX FRONT ROOM, 1ST STO... | — | Aug 19, 2006 |
| Jul 3, 2006 | B | NOV SENT OUT | SECTION 27-2005 ADMIN. CODE: PROPERLY SECURE THE LOOSE ELECTRICAL SWITCH BOX EAST WALL, FRONT ROOM 1ST STORY DUPLEX A... | — | Aug 19, 2006 |
| Jul 3, 2006 | B | NOV SENT OUT | SECTION 27-2005 ADMIN. CODE: REPLACE WITH NEW THE MISSING ELECTICAL SWITCH BOX COVERS FRONT AND REAR ROOMS, 1ST STORY... | — | Aug 19, 2006 |
| Jul 3, 2006 | B | NOV SENT OUT | SECTION 27-2005 ADMIN. CODE: PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR FRONT AND REAR ... | — | Aug 19, 2006 |
| Jul 3, 2006 | B | NOV SENT OUT | SECTION 27-2005 ADMIN. CODE: REPLACE WITH NEW THE BROKEN OR DEFECTIVE CELOTEX CEILING CELLAR THROUGHOUT | — | Aug 19, 2006 |
| Jul 3, 2006 | B | NOV SENT OUT | SECTION 27-2005 ADMIN. CODE: PROPERLY REPAIR THE BROKEN OR DEFECTIVE WINDOW SASHES THROUGHOUT,2ND STORY DUPLEX APT.1. | — | Aug 19, 2006 |