ECB violations

188-198 Parkside Avenue, Brooklyn • Block 05054 • Lot 0011

16 records

Environmental Control Board violations, which carry a hearing and a penalty.

Issued Violation Status Severity Description Penalty Balance due Hearing
Feb 28, 2023 39080410Z ACTIVE CLASS - 2 GAS VENT ON BURNER NEEDS TO BE HARD PIPED, BACKFLOW PREVENTOR LEAKING, NO STORAGE IN BOILER ROOM, COIL PLATE LEAKING ... $2,500 $0 May 10, 2023
Feb 28, 2023 39080411K ACTIVE CLASS - 2 FOUND PEERLESS ECT-06 SERIAL# 502734 20051 CORRECT VIOLATING CONDITION AND SUBMIT A CERTIFICATE OF CORRECTION $2,500 $0 May 10, 2023
Nov 13, 2018 39000733K RESOLVE CLASS - 2 SEWER PIPE LEAKING LEFT OF BOILER-CHIMNEY BASE DOOR IS DEFECTIVE $625 $0 Aug 5, 2019
Nov 13, 2018 39000734M RESOLVE CLASS - 2 BOILER FLUE PLATES LEFT SIDE HAVE DEFECTIVE BOLTS+GASKETS-STEAM RETURN REAR OF BOILER LEAKING-GAS METER ROOM HAS HOLE... $312 $0 Aug 5, 2019
Aug 20, 2013 34983963Y ACTIVE CLASS - 2 WORK DOES NOT CONFORM TO APPROVED CONSTRUCTION DOCUMENTS AND/OR APPROVED AMENDMENTS. FOR ALT II JOB#320247434 PERMIT ... $530 $0 Dec 30, 2013
Aug 31, 2009 32066861M RESOLVE CLASS - 2 32A50A50B. 32A WIRES ON WATER PUMP MUST BE HARDWIRED. 50A FLU PIPE NEEDS CLEAN OUT EVERY 15FT. 50B CELING ABOVE BOILE... $0 $0 Oct 26, 2009
Sep 29, 2008 34686846Y RESOLVE CLASS - 1 WORK W/O A PERMIT WORK NOTED AT CELLAR LEVEL PREMISES ERECTED FULL HEIGHT PARTITIONS CREATING 5 ROOMS 3 ROOMS USE AS ... $0 $0 Dec 18, 2008
Sep 29, 2008 34686845M RESOLVE CLASS - 1 OCCUPANCY CONTRARY TO THAT ALLOWED BY THE C OF O OR BLDG DEPT RECORDS C OF O 169794 ISSUED 3/17/60 INDICATES PREMISES... $2,400 $0 Dec 18, 2008
Sep 29, 2008 34686847X RESOLVE CLASS - 1 FAILURE TO MAINTAIN BLDG IN A CODE COMPLIANT MANNER DEFECT NOTED AT CELLAR LEVEL 2 WOOD JOIST FAULTY DEFECTIVE BROKEN... $250 $0 Dec 18, 2008
Jun 21, 2006 32049545X RESOLVE Hazardous B4B,50D,32A,50E,10A,50F,50A,50G,50B,50C 50A-OIL TANK LEAKING NEED TO BE TESTED. 50B-SEPERATE CONTROLLS FROM 1/4" LINE... $2,500 $0 Oct 16, 2006
Feb 8, 2005 32047062M RESOLVE Hazardous 3C/B4B 51/6A 50A/21B PEERLESS C.L. BOILER DOMESTIC HOT WATER SUPPLY OIL-FIRED 3C COLLAPSED FLUE PIPE. FLUE GAS EMISSI... $400 -$25 Feb 8, 2006
Feb 8, 2005 32047061K RESOLVE Non-Hazardous FULTON V.T. BOILER, 10 HP, NB 40009, OIL 1981 BQ9 (27-147) REFERENCED BOILER WAS INSTALLED AT THE CITED LOCATION AND ... $180 $0 Apr 18, 2005
Feb 8, 2005 32047063Y RESOLVE Non-Hazardous 50A/50B 50C/50D 34A/38 48AB PEERLESS C.L. BLR. LP STEAM, OIL-FIRED 50A) EXPOSED CONTROL INSTRUMENT SWITCH GEAR ON BOI... $350 -$25 Feb 8, 2006
Oct 28, 1998 32016566Y RESOLVE Non-Hazardous 3C,49. 3C-FLUE PIPE COLLAPSED. 49-NUST FIX COLLAPSING FLUE PIPE & RESEAL INTO CHIMNEY, REPLACE BROKEN BLOWDOWN VALVE ... $400 $0 Dec 14, 1998
Oct 28, 1998 32016565M RESOLVE Non-Hazardous 3C,49. 3C-FLUE PIPE COLLAPSED. 49-MUST FIX COLLAPSING FLUE PIPE & RESEAL PIPE INTO CHIMNEY. MUST INSTALL BLOWDOWN PIP... $400 $0 Dec 14, 1998
Oct 23, 1998 32016494Y RESOLVE Non-Hazardous 18Q,18B,49,.1 LWCUT OUT RELEIGH SWITCH NOT CONNECTED TO RESTORE. 2 FLUE PIPE DAMPER FALL DOWN TO REFIL PROPERLU 3 HAN... $0 $0 Mar 24, 1999