Maintenance code violations
43-55 East 21 Street, Brooklyn • Block 05063 • Lot 0009
2,402 records
HPD grades a violation A for non-hazardous through C for immediately hazardous.
| Issued | Class | Status | Violation | Apartment | Correct by |
|---|---|---|---|---|---|
| Mar 14, 2024 | B | VIOLATION CLOSED | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE CRACKED, SPLICED, WOOD DOOR SADDLE, AT NORTH WALL, ... | 6J | Apr 18, 2024 |
| Mar 14, 2024 | B | VIOLATION DISMISSED | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE MORTICE LOCKING DEVICE AT DOOR IN THE ENTRANCE LOCA... | 4A | Apr 18, 2024 |
| Mar 14, 2024 | A | VIOLATION CLOSED | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT ( APPROXIMATELY 1 SQFT ) CEIL... | 6J | Jun 17, 2024 |
| Mar 14, 2024 | B | VIOLATION CLOSED | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE WOOD DOOR SADDLE, AT EAST IN THE BATHROOM LOCATED A... | 6J | Apr 18, 2024 |
| Mar 14, 2024 | C | VIOLATION CLOSED | § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK OVER THE CEILING IN THE 1st ROOM FROM NORTH LOCATED AT AP... | 6J | Mar 20, 2024 |
| Mar 14, 2024 | B | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY SECURE THE LOOSE WASH BASIN AT SOUTH WALL IN THE BATHROOM LOCATED AT APT 6J, 6th STORY, 1... | 6J | Apr 18, 2024 |
| Mar 14, 2024 | A | VIOLATION DISMISSED | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE CEILING AND ALL WALLS IN... | 6J | Jun 17, 2024 |
| Mar 14, 2024 | B | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CRACKED AND MISSING TILES AT SOUTH A... | 6J | Apr 18, 2024 |
| Mar 14, 2024 | A | VIOLATION DISMISSED | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE CEILING AND WALLS IN THE... | 6J | Jun 17, 2024 |
| Mar 14, 2024 | B | VIOLATION CLOSED | § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK OVER THE CEILING IN THE 2nd ROOM FROM NORTH AT WEST LOCAT... | 6J | Apr 18, 2024 |
| Mar 14, 2024 | B | VIOLATION DISMISSED | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE ROTTEN WOOD FLOOR IN THE KITCHEN LOC... | 4A | Apr 18, 2024 |
| Mar 14, 2024 | A | VIOLATION DISMISSED | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE CEILING AND ALL WALLS IN... | 6J | Jun 17, 2024 |
| Mar 14, 2024 | B | VIOLATION DISMISSED | § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 4A, 4th STORY,... | 4A | Apr 18, 2024 |
| Mar 14, 2024 | B | VIOLATION CLOSED | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT ( APPROXIMATELY 12 SQ FT) SOU... | 4A | Apr 18, 2024 |
| Mar 14, 2024 | C | VIOLATION CLOSED | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE 1... | 6J | Mar 20, 2024 |
| Mar 14, 2024 | A | VIOLATION DISMISSED | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR IN THE FOYER LOCATED AT A... | 4A | Jun 17, 2024 |
| Mar 14, 2024 | C | VIOLATION CLOSED | § 27-2005, 2007 ADM CODE REMOVE THE ILLEGAL FASTENING CHAIN AND PADLOCK AT EXIT GATE, IN FRONT OF MASONRY RAMP , SOUT... | — | Mar 20, 2024 |
| Mar 14, 2024 | B | VIOLATION DISMISSED | § 27-2005 ADM CODE PROPERLY SECURE THE LOOSE WOOD DOOR SADDLE AT NORTH WALL IN THE BATHROOM LOCATED AT APT 4A, 4th ST... | 4A | Apr 18, 2024 |
| Mar 5, 2024 | B | VIOLATION DISMISSED | § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). DEFECTIVE LOCATED AT APT 5B, 5th STORY, 4... | 5B | Apr 9, 2024 |
| Mar 5, 2024 | B | VIOLATION DISMISSED | § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEFECTIVE LOCATED AT APT 5B, 5th STORY, 4th APARTMENT FROM SO... | 5B | Apr 9, 2024 |
| Mar 5, 2024 | B | VIOLATION CLOSED | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE COUNTER BALANCE AT UPPER SASH WINDOW, NORTH WALL IN... | 5B | Apr 9, 2024 |
| Mar 5, 2024 | B | VIOLATION CLOSED | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE COUNTER BALANCE AT LOWER SASH WINDOW IN THE BATHROO... | 5B | Apr 9, 2024 |
| Mar 5, 2024 | C | VIOLATION DISMISSED | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE COUNTER BALANCE AT LOWER SASH WINDOW LEADING TO FIR... | 5B | Mar 11, 2024 |
| Mar 4, 2024 | B | VIOLATION CLOSED | § 27-2037, 2038 HMC: PROVIDE A SAFE AND ADEQUATE SUPPLY OF ELECTRIC SERVICE TO THE FIXTURES AT CEILING IN THE PRIVATE... | 2G | Apr 8, 2024 |
| Mar 4, 2024 | B | VIOLATION CLOSED | § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). DEFECTIVE LOCATED AT APT 2G, 2nd STORY, 2... | 2G | Apr 8, 2024 |
| Mar 4, 2024 | B | VIOLATION CLOSED | § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEFECTIVE LOCATED AT APT 2G, 2nd STORY, 2nd APARTMENT FROM NO... | 2G | Apr 8, 2024 |
| Mar 4, 2024 | B | VIOLATION CLOSED | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING AND NORT... | 3B | Apr 8, 2024 |
| Mar 4, 2024 | B | VIOLATION CLOSED | § 27-2037, 2038 HMC: PROVIDE A SAFE AND ADEQUATE SUPPLY OF ELECTRIC SERVICE TO THE FIXTURES AT CEILING IN THE BATHROO... | 2G | Apr 8, 2024 |
| Mar 4, 2024 | B | VIOLATION CLOSED | § 27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES... | — | Apr 8, 2024 |
| Mar 4, 2024 | B | VIOLATION CLOSED | § 27-2005, 2007 ADM CODE REMOVE ALL ENCUMBRANCES CONSISTING OF HOUSEHOLD ITEMS AT PUBLIC HALL, 5th STORY | — | Apr 8, 2024 |
| Mar 4, 2024 | A | VIOLATION CLOSED | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE CEILLING IN THE 3rd ROOM... | 6J | Jun 7, 2024 |
| Mar 4, 2024 | B | VIOLATION CLOSED | § 27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES... | — | Apr 8, 2024 |
| Mar 4, 2024 | B | VIOLATION CLOSED | § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING LOCATED AT APT 1E, 1st STORY, 1st APARTMENT FROM EAST... | 1E | Apr 8, 2024 |
| Mar 4, 2024 | B | VIOLATION CLOSED | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... APPROX 16 SQ FT AT CEILING AND W... | 1E | Apr 8, 2024 |
| Mar 4, 2024 | B | VIOLATION CLOSED | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING IN THE ... | 6J | Apr 8, 2024 |
| Mar 4, 2024 | C | VIOLATION DISMISSED | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CL... | 1E | Mar 18, 2024 |
| Mar 4, 2024 | B | VIOLATION CLOSED | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING AND ALL ... | 1E | Apr 8, 2024 |
| Mar 4, 2024 | C | VIOLATION DISMISSED | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 1E, 1st ... | 1E | Mar 30, 2024 |
| Mar 4, 2024 | C | NOT COMPLIED WITH | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 1E, 1st STO... | 1E | Mar 30, 2024 |
| Mar 4, 2024 | B | VIOLATION DISMISSED | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING IN THE ... | 6J | Apr 8, 2024 |
| Mar 4, 2024 | B | VIOLATION CLOSED | § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING LOCATED AT APT 1E, 1st STORY, 1st... | 1E | Apr 8, 2024 |
| Mar 4, 2024 | B | VIOLATION CLOSED | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... APPROX 20 SQ FT AT CEILING AND E... | 1E | Apr 8, 2024 |
| Feb 21, 2024 | B | VIOLATION CLOSED | § 27-2005, 2007 ADM CODE REMOVE ALL ENCUMBRANCES CONSISTING OF HOUSEHOLD ITEM ( CONSTRUCTION MATERIALS) AT PUBLIC HAL... | — | Mar 27, 2024 |
| Feb 20, 2024 | B | VIOLATION CLOSED | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT WEST WALL, EAST ... | 5H | Mar 26, 2024 |
| Feb 20, 2024 | B | VIOLATION CLOSED | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE 1st ROOM FRO... | 5H | Mar 26, 2024 |
| Feb 20, 2024 | B | VIOLATION CLOSED | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE K... | 5H | Mar 26, 2024 |
| Feb 20, 2024 | B | VIOLATION CLOSED | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT SOUTH WALL AND C... | 5H | Mar 26, 2024 |
| Feb 20, 2024 | B | FIRST NO ACCESS TO RE- INSPECT VIOLATION | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT SOUTH WALL, NORT... | 5H | Mar 26, 2024 |
| Feb 20, 2024 | B | VIOLATION CLOSED | § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 5H, 5th STORY | 5H | Mar 26, 2024 |
| Feb 20, 2024 | A | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC FLOOR TILES IN THE BATHROOM ... | 5H | May 25, 2024 |