ECB violations
131 East 21 Street, Brooklyn • Block 05082 • Lot 0072
47 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Nov 18, 2021 | 35564331X | RESOLVE | CLASS - 2 | FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER CONTAINED IN SUMMONS/VIOLATION#39047735M ISSUED ON 9/17/2021 AND TO F... | $0 | $0 | Nov 2, 2022 |
| Sep 17, 2021 | 39047735M | RESOLVE | CLASS - 1 | AT TIME OF INSPECTION OBSERVED FIRE ESCAPE ACCESS WINDOW IN APT # 4K PARTIALLY OBSTRUCTED WITH A A/C UNIT AND SCREWED... | $1,250 | -$30 | Nov 2, 2022 |
| Oct 2, 2019 | 39010585R | RESOLVE | CLASS - 1 | CEASE USE ITEMS: 1) INOPERATIVE ROPE GRIPPER 2) EXTREMELY WOEN ROPE GRIPPER PADS; WEIGHT TEST REQUIRED IF NEW GRIPPER... | $312 | $0 | Feb 11, 2021 |
| Aug 25, 2018 | 38264795Z | RESOLVE | CLASS - 1 | 05M7,100M7. 05M07-CEASE USE ITEM. MISSING DOOR ZONE RESTRICTOR. THIS IS A SAFETY DEVICE TO ENSURE ELEVATOR PASSENGERS... | $1,250 | $0 | Nov 19, 2018 |
| Feb 28, 2018 | 38261569R | RESOLVE | CLASS - 1 | 5A10 CEASE USE ITEM. DOOR ZONE RESTRICTOR HAS BEEN TAMPERED WITH DISABLED AND RENDERED INOPERATIVE. THIS IS A SAFETY ... | $1,000 | $0 | May 24, 2018 |
| May 23, 2017 | 38255248P | RESOLVE | CLASS - 2 | 11L10,2L10,10H11,56Y2,56Y13,16J10,67L10. 11L10-CAR BUTTON DEFECTIVE REPAIR; 2L10-ALARM DEFECTIVE REPAIR; 10H11-CAR DO... | $530 | $0 | Jul 10, 2017 |
| May 23, 2017 | 38255247N | RESOLVE | CLASS - 2 | 5E1,5J1,16J10,56Y2,56Y13,67L10. 5E1-CAR DOOR RUBBING ADJUST; 5J1-CAR DOOR MISALIGNED ADJUST; 16J10-HOISTWAY DOOR MISA... | $530 | $0 | Jul 10, 2017 |
| Sep 4, 2014 | 35056239M | RESOLVE | CLASS - 1 | FAILURE TO COMPLY W/THE COMMISSIONER'S ORDER CONTAINED IN NOTICE OF VIOLATION #35086443R ISSUED ON 2/8/14. WORK W/O A... | $0 | $0 | Dec 8, 2014 |
| Jun 20, 2014 | 35052293P | RESOLVE | CLASS - 1 | FAILURE TO COMPLY WITH THE COMM ORDER CONTAINED IN NOV# 35086443R ISSUED ON 02/08/14.WORK W/O PERMIT IN CELLAR.ERECTI... | $0 | $0 | Nov 3, 2014 |
| Feb 8, 2014 | 35086444Z | RESOLVE | CLASS - 1 | OCCUPANCY CONTRARY TO THAT ALLOWED BY THE C OF O OR BLDG DEPT RECORDS.C OF O #47061 INDICATES 1 FAMILY AT CELLAR LEVE... | $0 | $0 | Sep 26, 2014 |
| Feb 8, 2014 | 35086443R | RESOLVE | CLASS - 1 | WORK W/O A PERMIT. WORK NOTED AT CELLAR LEVEL. CREATED FULL HEIGHT PARTITION WALLS FOR 2 ROOMS (1 BEDRM,1 LIVING RM/D... | $0 | $0 | Sep 15, 2014 |
| Jun 9, 2010 | 34836374X | RESOLVE | CLASS - 1 | SUPERVISION OR USE OF RIGGING EQUIPMENT W/O A RIGGER'S LICENSE. NOTE: C-HOOK SUSPENDED SCAFFOLD INSTALLED AT EXPOSURE... | $24,000 | $0 | Aug 2, 2010 |
| Jun 9, 2010 | 34857600H | RESOLVE | CLASS - 1 | INADEQUATE SAFETY MEASURES OPERATION OF HOISTING EQUIPMENT IN UNSAFE MANNER. NOTE: C-HOOK ROPE SCAFFOLD SLUNG FROM MA... | $24,000 | $0 | Aug 2, 2010 |
| Aug 18, 2009 | 34796591Z | RESOLVE | CLASS - 2 | RESIDENCE ALTER FOR OCCUP AS DWELLING FOR MORE THAN LEGALLY APPROVED# OF FAMILIES NOTE PER BLDG DEPT RECORDS PREMISES... | $6,000 | $0 | Oct 5, 2009 |
| Aug 18, 2009 | 34796588H | RESOLVE | CLASS - 1 | WORK W/O A PERMIT NOTE AT CELLAR LVL FULL PARTITION WALLS ERECTED FROM FL TO CEILING CREATING 4 ILLEGAL CLASS A APT P... | $8,000 | $0 | Oct 5, 2009 |
| Aug 18, 2009 | 34796590R | RESOLVE | CLASS - 1 | OCCUPANCY CONTRARY TO THAT ALLOWED BY THE BLDG DEPT RECORDS NOTE BLDG DEPT RECORDS INDICATE 75 CLASS A UNITS IN BLDG ... | $12,000 | $0 | Oct 5, 2009 |
| Mar 3, 2009 | 38201518M | RESOLVE | CLASS - 2 | 03110.21D06.100M07.03I10.09A01.16B01.16T07.05M07.77Q03.70O02.34M07.60Q03.16I11.16D06.39M07.09 CAR FL DAMAGED 21 PROPE... | $2,500 | $0 | Apr 27, 2009 |
| Nov 29, 2008 | 34743158Z | RESOLVE | CLASS - 1 | FAILURE TO COMPLY WITH COMM'S ORDER TO CORRECT VIO 334640169M FOR WORK W/O PERMIT @ CELLAR INSTALLED PLUMBING & PARTI... | $0 | -$1,789 | Jan 9, 2013 |
| Nov 18, 2008 | 38193356L | RESOLVE | CLASS - 2 | 08V01.60B10.56Y13.56O02.42G11.52M07.70O02.59M07.16B01.16I10.09I10.03I10.39O02.39D06.03I10.39O02.03I10.34O02.77X10.42G... | $2,500 | $0 | Jan 12, 2009 |
| May 30, 2008 | 38184964K | RESOLVE | Non-Hazardous | 27-987 08 V 01 21 D 06 31 H 10 66 0 02 52 H 14 72 H 10 32 D 06 33 Q 03 60 D 06 10 M 07 32D/06 CTWT GUARD UNSECURED 33... | $0 | $0 | Jul 21, 2008 |
| May 30, 2008 | 38184965M | RESOLVE | Non-Hazardous | 27-987 26 M 10 08 V 01 03 I 11 38 Q 03 43 H 10 51 H 11 55 T 02 66 0 0210 H 11 16 J 01 20 I 11 CEASE USE 26M/10 CAR TO... | $800 | $0 | Jul 21, 2008 |
| May 5, 2008 | 34640169M | RESOLVE | Hazardous | WORK W/O A PERMIT. WORK NOTED: BUILT PARTITIONS IN CELLAR CREATED APARTMENT WITH LIVING ROOM BEDROOM & 3PC BATHROOM W... | $0 | $0 | Dec 24, 2008 |
| May 5, 2008 | 34640168K | RESOLVE | Hazardous | OCCUPANCY CONTRARY TO THAT ALLOWED BY BUILDING DEPARTMENT RECORDS: 1 FAMILY OCCUPIED IN UTILITY ACCESSORY CELLAR OF M... | $0 | $0 | Dec 24, 2008 |
| Sep 6, 2005 | 34491926Y | RESOLVE | Hazardous | EXIT PASSAGEWAY OR CORRIDOR:TOTAL OBSTRUCTION. METAL GATES ENCLOSING FIRE ESCAPES AT GROUND LEVEL ARE TOTAL OBSTRUCTE... | $2,500 | $0 | Oct 17, 2005 |
| Jan 14, 2000 | 38092712X | RESOLVE | Non-Hazardous | 73X75U,2X,62M. TOE GUARD. | $2,500 | $0 | Feb 28, 2000 |
| Jan 14, 2000 | 38092711Y | RESOLVE | Non-Hazardous | 75U,73M,2X,62M. PROVIDE CITY ID NUMBER. TOE GUARD. | $2,500 | $0 | Feb 28, 2000 |
| Jan 6, 2000 | 34221701N | RESOLVE | Non-Hazardous | FAILURE TO MAINTAIN BUILDING . DEFECT IS: A SECTION OF SHEETROCK IN THE BATHROOM OF APT 2K ON THE CEILING HAS FELL AP... | $2,500 | $0 | Nov 20, 2000 |
| Jul 26, 1999 | 34212747Y | RESOLVE | Hazardous | FAILURE TO MAINTAIN BUILDING INTERIOR. DEFECTS ARE: LARGE VERTICAL ANDHORIZONTAL CRACKS ON WALL BETWEEN BATHROOM AND ... | $2,500 | $0 | Sep 13, 1999 |
| Aug 29, 1998 | 38077812H | RESOLVE | Hazardous | 01I,02I,05I,08V,15I,18L,20I,24L,28I,31M,33H,35O,46H,47H,50Y,58O,59O, 73O,75T, 01-CEASE USE FOR STOP SW AND BASEMENT D... | $5,000 | $0 | Oct 19, 1998 |
| Aug 29, 1998 | 38077811X | RESOLVE | Hazardous | 01I,02I,05I,08V,15I,18L,20I,24L,28I,31M,33H,35O,46H,47H,50Y,58O,59O, 73O,75T, 01-CEASE USE FOR STOP SW & ALARM NOT WO... | $5,000 | $0 | Oct 19, 1998 |
| Aug 27, 1997 | 38062914R | RESOLVE | Non-Hazardous | 73X 73-RESTOR TO FULL SERVICE. | $0 | $0 | Dec 1, 1997 |
| Aug 27, 1997 | 38062913P | RESOLVE | Non-Hazardous | 73X 73 RESOTE TO FULL SERVICE. | $0 | $0 | Dec 1, 1997 |
| Oct 27, 1995 | 38052677N | RESOLVE | Non-Hazardous | 73X, 73-RESTORE ELEVATOR SERVICE FOR COMPLETE INSPECTION. | $100 | $0 | Mar 11, 1996 |
| Oct 27, 1995 | 38052676L | RESOLVE | Non-Hazardous | 05L,08V,15L,17I,47K,57O,. | $500 | $0 | May 13, 1996 |
| Jan 5, 1995 | 38047026N | RESOLVE | Non-Hazardous | 35M. 35-REPAACE MISSING WINDOW PANES IN MACHINE ROOM. | $0 | $0 | Mar 6, 1995 |
| Jan 5, 1995 | 38046250N | RESOLVE | Non-Hazardous | 02L,05L,08V,15L,37U,50U,54U,51O. 17-PROVIDE APPROVED - TYPE VISION PANEL GUARDS. | $0 | $0 | Mar 6, 1995 |
| Jun 1, 1994 | 38041753M | RESOLVE | Non-Hazardous | 08V,09H,05L,17I,21X,36D,37G,37L,53X,55X,57O,73O,74M,75,74A,(74)NYC DESIGNATED ELEVATOR NO (AMEND RULE 208.10)AND CAPA... | $200 | $0 | Sep 19, 1994 |
| Jun 1, 1994 | 38041754Y | RESOLVE | Non-Hazardous | 05L,08V,09H,15L,17I,21X,36D,37G,37L,53X,55X,57O.73O,74AM,74BM,785M,74C,(74)NYC DESIGNATED ELEV.NO(AMEN'D.208.10)AND C... | $200 | $0 | Sep 19, 1994 |
| Dec 10, 1993 | 38038948P | RESOLVE | Non-Hazardous | 2B,14L,22D,73O. | $0 | $0 | Feb 14, 1994 |
| Dec 10, 1993 | 38038947N | RESOLVE | Non-Hazardous | 12B,11Q,74L,15J,17I,73O. | $0 | $0 | Feb 14, 1994 |
| Jan 15, 1993 | 38030305P | RESOLVE | Non-Hazardous | 02L,14I,15H,17I,18Q,21L,37G,57O. | $200 | $0 | May 19, 1997 |
| Jan 15, 1993 | 38030306R | RESOLVE | Non-Hazardous | 02L,14I,22D,57O. | $200 | $0 | May 19, 1997 |
| May 11, 1992 | 38025294M | RESOLVE | Non-Hazardous | 02B,13M,14M,15L,17I,18L,21X,37G,53M,74#,(74)REPLACE WORN CAR DOOR STADDLE. | $0 | $0 | Jun 22, 1992 |
| May 11, 1992 | 38025295Y | RESOLVE | Non-Hazardous | 73X,11Q,14M,02L,37G,(73)RESTORE ELEVATOR SERVICE FOR COMPLETE INSPECTION. | $150 | $0 | Jun 22, 1992 |
| Apr 15, 1992 | 38021636P | RESOLVE | Non-Hazardous | 18O,18. FASTEN 1ST FLOOR DOOR LOCK SECURELY. | $75 | $0 | Jun 15, 1992 |
| Jul 2, 1991 | 38012864M | RESOLVE | Non-Hazardous | 73X,(73)RESTORE ELEVATOR SERVICE FOR COMPLETE INSPECTION | $1,000 | $0 | Oct 21, 1991 |
| Jul 2, 1991 | 38012865Y | RESOLVE | Non-Hazardous | 37#,73X,(37)INSTALLED NEW CONTROLLER WITHOUT A PERMIT. (73)RESTORE ELEVATOR SERVICE FOR COMPLETE INSPECTION | $2,000 | $0 | Oct 21, 1991 |