Maintenance code violations
101-103 Erasmus Street, Brooklyn • Block 05105 • Lot 0001
260 records
HPD grades a violation A for non-hazardous through C for immediately hazardous.
| Issued | Class | Status | Violation | Apartment | Correct by |
|---|---|---|---|---|---|
| Jun 17, 2011 | A | VIOLATION CLOSED | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT CEILING AT PUBLIC HALL, 3rd ... | — | Sep 20, 2011 |
| Jun 17, 2011 | B | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDED PLASTER CEILING AT PUB... | — | Jul 22, 2011 |
| Jun 16, 2011 | B | VIOLATION CLOSED | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING AND WALLS I... | 3R | Jul 21, 2011 |
| Jun 16, 2011 | B | VIOLATION CLOSED | § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF EXPOSED ELECTRIC WIRING AT CEILING AND SOUTH WALL I... | 3R | Jul 21, 2011 |
| Jun 16, 2011 | B | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC TILE FLOOR IN THE BATHROOM L... | 3R | Jul 21, 2011 |
| Jun 16, 2011 | B | VIOLATION CLOSED | § 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS BATHTUB IN THE BATHROOM LOCATED AT APT 3R, 3rd STORY, 2n... | 3R | Jul 21, 2011 |
| Jun 16, 2011 | A | VIOLATION CLOSED | § 27-2026 ADM CODE RESET, SO AS TO SECURE A PROPER AND TIGHT CONNECTION, THE WATER CLOSET BOWL .. IN THE BATHROOM LOC... | 3R | Sep 19, 2011 |
| Jun 16, 2011 | C | VIOLATION CLOSED | § 27-2005 HMC:TRACE AND REPAIR THE SOURCE AND ABATE THE NUISANCE CONSISTING OF MOLD ... AT CEILING , EAST AND SOUTH W... | 3R | Jun 22, 2011 |
| Jun 16, 2011 | B | VIOLATION CLOSED | § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK AT CEILING IN THE BATHROOM LOCATED AT APT 3R, 3rd STORY, ... | 3R | Jul 21, 2011 |
| Jun 16, 2011 | B | VIOLATION CLOSED | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING AND WALLS I... | 3R | Jul 21, 2011 |
| Jun 16, 2011 | B | VIOLATION CLOSED | § 27-2046.1, 2046.2 HMC: PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANC... | 3R | Jul 21, 2011 |
| Jun 16, 2011 | B | VIOLATION CLOSED | § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 3R, 3rd STOR... | 3R | Jul 21, 2011 |
| Jun 16, 2011 | B | VIOLATION CLOSED | § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF EXPOSED ELECTRIC WIRING AT CEILING IN THE 1st ROOM ... | 3R | Jul 21, 2011 |
| Jun 16, 2011 | B | VIOLATION CLOSED | § 27-2005 ADM CODE REPLACE WITH NEW THE MISSING ELECTRIC LIGHT FIXTURE AT CEILING IN THE 1st ROOM FROM NORTH AT WEST ... | 3R | Jul 21, 2011 |
| Jun 16, 2011 | B | VIOLATION CLOSED | § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK AT CEILING IN THE 1st ROOM FROM NORTH AT WEST LOCATED AT ... | 3R | Jul 21, 2011 |
| Jun 16, 2011 | B | VIOLATION CLOSED | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING IN THE 1st ... | 3R | Jul 21, 2011 |
| Jun 16, 2011 | B | VIOLATION CLOSED | § 27-2005 ADM CODE REPLACE WITH NEW THE MISSING WINDOW IN THE 2nd ROOM FROM NORTH AT WEST LOCATED AT APT 3R, 3rd STOR... | 3R | Jul 21, 2011 |
| Jun 16, 2011 | B | VIOLATION CLOSED | § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF UNCAPED SHUT OFF VALVE AT HEAT RISER IN THE 2nd ROO... | 3R | Jul 21, 2011 |
| Jun 16, 2011 | B | VIOLATION CLOSED | § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF LOCK WITH KEY OPERATED INSTALLED AT DOOR TO ROOM WI... | 3R | Jul 21, 2011 |
| Jun 16, 2011 | B | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY SECURE THE LOOSE DOOR OFF HINGES IN THE 2nd ROOM FROM NORTH AT EAST LOCATED AT APT 3R, 3r... | 3R | Jul 21, 2011 |
| Jun 16, 2011 | B | NOT COMPLIED WITH | § 27-2044 ADM CODE REPLACE OR REPAIR THE SELF-CLOSING THE DOORS THAT IS MISSING OR DEFECTIVE .. IN THE ENTRANCE LOCAT... | 3R | Jul 21, 2011 |
| Jun 16, 2011 | C | VIOLATION CLOSED | § 27-2005, 2007 ADM CODE REMOVE THE ILLEGAL FASTENING DOUBLE CYLINDER KEY OPERATED LOCK INSTALLED AT DOOR IN THE ENTR... | 3R | Jun 22, 2011 |
| Jun 16, 2011 | A | NOT COMPLIED WITH | § 300 M/D LAW FILE PLANS AND APPLICATION AND LEGALIZE THE FOLLOWING ALTERATION OR RESTORE TO THE LEGAL CONDITION EXIS... | — | Sep 19, 2011 |
| Jun 16, 2011 | A | VIOLATION CLOSED | § 27-2014 ADM CODE AND DEPT. RULES AND REGULATIONS. SCRAPE AND REMOVE RUST SCALES AND PAINT WITH 2 COATS OF PAINT FIR... | — | Sep 19, 2011 |
| Apr 27, 2011 | C | VIOLATION CLOSED | § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK AT SKYLIGHT AT PUBLIC HALL, 3rd STORY | — | May 3, 2011 |
| Apr 25, 2011 | B | FIRST NO ACCESS TO RE- INSPECT VIOLATION | § 27-2044 ADM CODE REPLACE OR REPAIR THE SELF-CLOSING THE DOORS THAT IS MISSING OR DEFECTIVE ... IN THE ENTRANCE LOCA... | 2R | May 30, 2011 |
| Apr 25, 2011 | B | VIOLATION CLOSED | § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF KEY OPERATED LOCK INSTALLED AT DOOR, PREVENT ACCESS... | 2R | May 30, 2011 |
| Apr 12, 2011 | B | VIOLATION CLOSED | § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING, LOCATED AT APT 2F, 2nd STORY, 1s... | 2F | May 17, 2011 |
| Apr 12, 2011 | B | FIRST NO ACCESS TO RE- INSPECT VIOLATION | § 27-2044 ADM CODE REPLACE OR REPAIR THE SELF-CLOSING THE DOORS THAT IS MISSING OR DEFECTIVE AT ENTRANCE, LOCATED AT ... | 2F | May 17, 2011 |
| Apr 12, 2011 | B | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR, , AT PUBLIC HALL, 2nd ST... | — | May 17, 2011 |
| Apr 12, 2011 | B | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR , AT PUBLIC HALL, 3rd STO... | — | May 17, 2011 |
| Apr 12, 2011 | A | VIOLATION CLOSED | § 27-2011 ADM CODE CLEANSE TO THE SATISFACTION OF THIS DEPARTMENT THE URINE ODOR AT ALL STORIES PUBLIC HALL, 103 ERAS... | — | Jul 16, 2011 |
| Apr 12, 2011 | A | VIOLATION CLOSED | § 27-2011 ADM CODE CLEANSE TO THE SATISFACTION OF THIS DEPARTMENT THE ALL FLOOR AND STAIRS ALL STORIES AT PUBLIC HALL... | — | Jul 16, 2011 |
| Apr 12, 2011 | B | VIOLATION CLOSED | § 27-2010, 2011, 2012 ADM CODE CLEANSE AND DISINFECT TO THE SATISFACTION OF THIS DEPARTMENT AFTER REMOVING THE . URIN... | — | May 17, 2011 |
| Apr 12, 2011 | A | VIOLATION CLOSED | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT ALL WALLS AT PUBLIC HALL 1 S... | — | Jul 16, 2011 |
| Apr 12, 2011 | C | VIOLATION CLOSED | § 27-2005 HMC:TRACE AND REPAIR THE SOURCE AND ABATE THE NUISANCE CONSISTING OF MOLD ... AT ALL WALLS AND CEILING 30 S... | 3R | Apr 18, 2011 |
| Apr 12, 2011 | C | VIOLATION CLOSED | § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF UNCAPPED STEAM PIPE, LOCATED AT APT 3R, 3rd STORY, ... | 3R | Apr 18, 2011 |
| Apr 12, 2011 | B | VIOLATION CLOSED | § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 3R, 3rd STORY,... | 3R | May 17, 2011 |
| Apr 12, 2011 | B | NOT COMPLIED WITH | § 27-2044 ADM CODE REPLACE OR REPAIR THE SELF-CLOSING THE DOORS THAT IS MISSING OR DEFECTIVE ... AT ENTRANCE ..., LOC... | 3R | May 17, 2011 |
| Apr 12, 2011 | C | VIOLATION CLOSED | § 27-2005, 2007 ADM CODE REMOVE THE ILLEGAL FASTENING DOUBLE CYLINDER KEY OPERATED LOCK AT DOORS IN ENTRANCE 103 ERAS... | 3R | Apr 18, 2011 |
| Apr 12, 2011 | B | VIOLATION CLOSED | § 27-2005, 2007 ADM CODE FIRE EGRESS DEFECTIVE. MAKE STATIONARY THE IRON LADDER LEADING TO SCUTTLE OPENING IN ROOF SC... | — | May 17, 2011 |
| May 10, 2010 | B | VIOLATION CLOSED | § 27-2005 ADM CODE REPLACE WITH NEW THE MISSING BALUSTER OF THE BALUSTRADE AT PUBLIC HALL STAIRS, 3rd STORY | — | Jun 14, 2010 |
| Aug 1, 2007 | B | NOT COMPLIED WITH | § 300, 301, 302, M/D LAW FILE PLANS AND OBTAIN A CERTIFICATE OF OCCUPANCY TO LEGALIZE THE FOLLOWING ALTERATION OR RES... | FIRE | Sep 5, 2007 |
| Jul 28, 2006 | A | VIOLATION CLOSED | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT CEILING NORTHWEST ROOM 3 STY... | 3 | Nov 24, 2006 |
| Jul 28, 2006 | A | NOT COMPLIED WITH | § 27-2014 ADM CODE PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE EXTERIOR WINDOW FRAMES AND SASHES 2 AND 3 STY WES... | — | Nov 24, 2006 |
| Jul 28, 2006 | A | VIOLATION CLOSED | § 27-2048 ADM CODE PAINT OR POST A SIGN INDICATING FLOORS 1 TO 3 STY PUBLIC HALL | — | Nov 24, 2006 |
| Jul 28, 2006 | A | NOT COMPLIED WITH | § 27-2014 ADM CODE PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE EXTERIOR WINDOW FRAMES AND SASHES 2 AND 3 STY SOU... | — | Nov 24, 2006 |
| Jul 28, 2006 | A | VIOLATION DISMISSED | D26-41.03 ADM CODE FILE WITH THIS DEPARTMENT A REGISTRATION AND OCCUPANCY STATEMENT OF BUILDING. | — | Nov 24, 2006 |
| Jul 28, 2006 | A | VIOLATION DISMISSED | D26-20.08,20.09 ADM CODE FILE CERTIFICATION OF SATISFACTORY INSTALLATION OF SMOKE DETECTING DEVICE IN ACCORDANCE WITH... | — | Nov 24, 2006 |
| Jul 28, 2006 | A | VIOLATION CLOSED | § 329, M/D LAW AND DEPT. RULES AND REGS. PROVIDE A COMPLETED CERTIFICATE OF INSPECTION VISITS IN A PROPER FRAME AT OR... | — | Nov 24, 2006 |