ECB violations
2020 Albemarle Road, Brooklyn • Block 05124 • Lot 0007
46 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Jun 17, 2026 | 39192857L | ACTIVE | CLASS - 1 | CEASE USE ITEMS 1) INOPERATIVE DOOR LOCK MONITOR (A17.3 3.1.12). 2) INMPROPERLY RE-ROPED RELEASE CARRIER(2.17.15). CL... | $1,250 | $1,250 | Aug 26, 2026 |
| Aug 26, 2022 | 39069134Y | RESOLVE | CLASS - 2 | 2.X.10 PHONE INOPERATIVE REPAIR & TEST. 97.M.7 FIRE SERVICE MISSING INSTALL & TEST | $0 | $0 | Jul 5, 2023 |
| Jun 29, 2022 | 39065016P | RESOLVE | CLASS - 1 | CEASE USE ITEM; INOPERATIVE ZONE LOCK RESTRICTOR. CLASS 2 ITEMS; MISSING IN CASE OF FIRE SIGNS WHERE NEEDED. REPAIR 1... | $1,250 | $1,250 | Jul 5, 2023 |
| May 24, 2022 | 39062732M | RESOLVE | CLASS - 2 | MISSING BOLTS & DOGS ON BOILER DOORS,RELIEF VALVES NOT PIPED DOWN,PIPE ROTTED ON 51-2 & HOT WATER PIPE,OIL LK AT SUPP... | $0 | $0 | Sep 28, 2022 |
| Jan 17, 2019 | 38266582Y | RESOLVE | CLASS - 1 | 97X17 THE ONLY ELEVATOR IN BUILDING OUT OF SERVICE. UPON INSPECTION THE DEVICE IS FOUND TO BE OUT OF SERVICE CREATING... | $1,250 | $1,250 | Apr 22, 2019 |
| Sep 5, 2017 | 38257900X | RESOLVE | CLASS - 2 | 8Y1,5E1,10H11,16J10,99BB5,56Y2,56Y13,57M7,77K10. (8V)CAR FLR TO LANDING SILL NOT LEVEL ADJUST. (5E)CAR DOOR RUBBING A... | $0 | $0 | Oct 23, 2017 |
| Jul 13, 2017 | 38256475J | RESOLVE | CLASS - 2 | 67X10,29Q03,10M07,40M07. 67X10-REPAIR EMERGENCY PHONE; 29Q03-DOOR OPERATOR COVER MISSING; 10M07-MISSING THE DOOR GOB;... | $0 | $0 | Aug 28, 2017 |
| Jan 18, 2017 | 38252440L | RESOLVE | CLASS - 2 | 5X10,14M7,60L10,40Z13,40O2. 5X10-DOOR RESTRICTOR INOPERATIVE REPAIR; 14M7; 60L10, 40Z13,40O2. | $500 | $0 | Mar 6, 2017 |
| Dec 10, 2016 | 38251378P | RESOLVE | CLASS - 1 | 5D10,14M7,2B10,39M7. (5D)REPAIR NOTIFIED DOOR ZONE RESTRICTOR. (14M)PROVIDE MIRROR IN CAR. (2B)REPAIR PHONE IN CAR. (... | $1,000 | $0 | Apr 3, 2017 |
| Jun 30, 2016 | 38243865M | RESOLVE | CLASS - 1 | CU08V01,67X10,16E1,38I10,07M07,52E10,56Y01,60Q03,60I10,60B07,59U15,70O02,70P16,57BB07,29Q03,39Q03,39I10,26D06,80M07,4... | $1,000 | $0 | Aug 15, 2016 |
| Jun 16, 2016 | 38241545Y | RESOLVE | CLASS - 1 | 16I11,05M07,39O02,40Y02,59M07,67X10,70O02. 16I11-BASEMENT HOISTWAY DOOR DAMAGED (REPLACE); 05M07 CAR DOOR RESTRICTOR ... | $2,500 | $0 | Sep 7, 2016 |
| Mar 23, 2016 | 38239825X | RESOLVE | CLASS - 1 | 16-I-11,10-K-44,05-M-07,39-O-02,40-Y-02,67-X-10,70-O-02,59-M-07:16-I-11-BSMT HOISTWAY DOOR DAMAGED & LANDING SILL REP... | $1,000 | $0 | Jul 18, 2016 |
| Sep 25, 2015 | 35160858L | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN BLDG WALL(S)OR APPURTENANCES.NOTED:@ EXP.(1)ALONG E 21 STREET,PARAPET WALL IS IN DISREPAIR,SOME S... | $500 | $0 | Nov 9, 2015 |
| Jun 23, 2015 | 35116362J | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN BLDG WALLS OR APPURTENANCES. NOTED: 1)THERE ARE DEFECTIVE PIECES OF STONE COPING AT THE PERIMETER... | $500 | $0 | Aug 10, 2015 |
| May 18, 2015 | 38236239J | RESOLVE | CLASS - 1 | 97X10 ONLY ELEVATOR IN BLDG OT OF SERVICE THIS AFFECTS A SIGNIFICANT NUMBER OF TENANT THEREBY CREATING A HAZARDOUS CO... | $2,500 | $0 | Jul 6, 2015 |
| Feb 6, 2015 | 35117923P | RESOLVE | CLASS - 3 | FAILURE TO MAINTAIN BLDG WALL(S)OR APPURTENANCES.NOTED @ MAIN ENTRY ABOVE DOOR,ORNAMENTAL WOOD ADD-ON HAS CRACK & IS ... | $0 | $0 | Mar 23, 2015 |
| Feb 11, 2014 | 38230058N | RESOLVE | CLASS - 2 | 70O02,40I10,60B07,97O02. 70O02-DIRTY PIT; 40I10-MOTOR ROOM WINDOW BROKEN; 60B07-INSUFFICIENT LIGHTING MACHINE SPACE; ... | $250 | $0 | Mar 31, 2014 |
| Jul 16, 2013 | 34997574H | ACTIVE | CLASS - 1 | SEC. EC 300.3.B. RACEWAY IS NOT PROVIDED FOR CONDUCTORS. APT 3B IS BEEN FED POWER FROM THE 3RD FLR HALLWAY FIXTURE W/... | $1,600 | $0 | Nov 8, 2013 |
| Jul 16, 2013 | 35021162N | ACTIVE | CLASS - 1 | SEC. EC 300.3B. PHASE AND GROUNDED CONDUCTORS ARE NOT GROUPED. APT 3B IS BEING FED POWER FROM A SINGLE ELECTRICAL CON... | $400 | $0 | Nov 4, 2013 |
| Mar 6, 2013 | 38226054Y | RESOLVE | CLASS - 2 | *14J1,05R09,40I10,61G11,42H11,32H11,100P16*08V01,70O02. RECURRING CONDITIONS PREVIOUSLY CITED IN OV 382252862;14J-ADJ... | $1,250 | $0 | Apr 22, 2013 |
| Jan 11, 2013 | 38225286Z | RESOLVE | CLASS - 2 | B251:14J01,05R09,61G11,08V01,40I10,40M07,59J01,42H11,32H11,05J01,23M07,16T07,77M07,70O02,100P16.14J:ADJUST FOR PROPER... | $500 | $0 | Feb 25, 2013 |
| Nov 20, 2012 | 38224126P | RESOLVE | CLASS - 2 | 08J10,05J10,40Q07,41T07,41D10. 8J10-IN LOBBY CAR TO SILL MISALIGNED; -5J10-CAR POOR MISALIGNED;40Q07-BACK OF MAIN MAC... | $0 | $0 | Jan 7, 2013 |
| May 16, 2012 | 34953464M | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN BUILDING WALLS OR APPURTENANCES. IN THAT AT ROOF LEVEL MASONRY CAPING ON TOP OF PARAPET WALL IS D... | $250 | $0 | Jul 2, 2012 |
| Jan 6, 2012 | 34930438R | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN EXTERIOR BUILDING WALL.SPOILING & MISSING SECTION OF COPING STONE AT PARAPET & SPOILING MISSING S... | $620 | $0 | Feb 27, 2012 |
| Nov 7, 2011 | 34929884Z | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN BUILDING WALLS OR APPURTENANCES. NOTE: COPING STONES AT ROOF PARAPET WALL SPOILING AND SECTION MI... | $1,000 | $0 | Mar 26, 2012 |
| Oct 18, 2011 | 38218808L | RESOLVE | CLASS - 2 | 8V1,59B1,68M7,72M7,26D6. 8V1-ADJUST LEVELING. 59B1- ADJUST BRAKE. 68M7- PROVIDE MAINTANCE LOG. 72M7-PROVIDE PIT STOP ... | $0 | $0 | Dec 5, 2011 |
| May 3, 2011 | 34903828Z | RESOLVE | CLASS - 2 | NOTE AT PARAPET LVL COPY STONES AND CONCRETE BAND COURSE IS SPALLING SECTIONS MISSING AND DEFECTIVE REM: PROVIDE SIDE... | $0 | $0 | Jun 20, 2011 |
| Nov 23, 2009 | 38207708K | RESOLVE | CLASS - 2 | 12Q3.16T7.60X10.98BB5.59M COTTER PINS ON BRAKE MOUNTING POSTS 40I WINDOW 40M STAIR HANDRAIL 23M 4FL UP BUTTON 24L WHE... | $2,500 | $0 | Jan 11, 2010 |
| Oct 14, 2009 | 38206637H | RESOLVE | CLASS - 1 | 03I10.05M10.100B11.42N956Y13 CUI 03I VENTILATION HOLES DAMAGED EXPOSING SHAFT 05MGLASS MISSING GRILL INSUFICIENT 1003... | $5,000 | $0 | Dec 7, 2009 |
| Mar 4, 2009 | 34767907N | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN EXTERIOR BUILDING WALLS OR APPURTENANCES. DEFECTS NOTED: BUILDING FOUND WITH BROKEN & DEFECTIVE F... | $2,500 | $0 | Mar 8, 2010 |
| Mar 4, 2009 | 34767906L | RESOLVE | CLASS - 2 | OCCUPANCY CONTRARY TO THAT ALLOWED BY C/O # OR DEPT RECORDS NOTED CELLAR FOUND W/ ROOMS ARRANGED AND OCCUPIED AS SPAC... | $6,000 | $0 | Mar 8, 2010 |
| Mar 4, 2009 | 34767749R | RESOLVE | CLASS - 2 | WORK W/ A PERMIT ILLEGAL WORK NOTED FULL HEIGHT PARTITION FOUND ERECTED CELLAR TO SUBDIVIDE EXISTING RM IN ORDER TO C... | $0 | $0 | Sep 12, 2011 |
| Jan 18, 2008 | 38179970K | RESOLVE | Non-Hazardous | 14M07,10M07,05M07,25D06,39I10,26U05,66O02,51O02,39P16.10M-2ND DOOR GIB.05M-CAR GATE VISION PANEL GLASS.39I-STEP & RAI... | $350 | $0 | Sep 8, 2008 |
| Nov 25, 2006 | 34556846Z | RESOLVE | Non-Hazardous | FAILURE TO COMPLY W/ COMMISSIONERS ORDER TO OBTAIN A PERMIT TO CORRECTECB #34532051Z FOR WORK W/O A PERMIT AT CELLAR ... | $1,500 | $0 | Dec 3, 2007 |
| Jul 11, 2006 | 34532051Z | RESOLVE | Hazardous | WORK W/O A PERMIT HAZ NOTED:IN CELLAR 2 APT WERE BUILT WITH FULL HIGH PARTITION WALLS/DOORS & ALL NECESSARY PLUMBING ... | $800 | $0 | Dec 3, 2007 |
| Jul 11, 2006 | 34532050R | RESOLVE | Hazardous | RESIDENCE ALTERED FOR OCCUPANCY AS A DWELLING FOR MORE THAN LEGALLY APPROVED # OF FAMILIES. NOTED:COFO# 66378 INDICAT... | $5,300 | $0 | Jan 14, 2008 |
| Oct 5, 2005 | 34496753H | RESOLVE | Hazardous | OCCUPANCY CONTRARY TO THAT ALLOWED THE BLDG DEPARTMENT RECORDS CELLAR OF MULTI DWELLING OCCUPIED AS DWELLING UNITS WI... | $800 | $0 | Dec 3, 2007 |
| Oct 5, 2005 | 34496754J | RESOLVE | Hazardous | WORK W/O A PERMIT HAZARDOUS. WORK NOTED: PARTITIONS ERECTED TO CREATE SEPARATE ROOM, GAS LINE INSTALLED IN ILLEGALLY ... | $800 | $0 | Dec 3, 2007 |
| Oct 5, 2005 | 34496755L | RESOLVE | Hazardous | FAILURE TO PROVIDE TWO MEANS OF EGRESS FROM ROOM OR SPACE WHERE REQUIRED. APPROX. FOUR (4) DWELLING UNITS CREATED IN ... | $480 | $0 | Dec 3, 2007 |
| Jun 27, 2001 | 34298961P | RESOLVE | Non-Hazardous | FAILURE TO MAINTAIN BUILDING EXTERIOR WALL: DEFECT IS: BROKEN AND MISSING MASONRY COPING: AT ROOF, FRONT, NORTH. SUGG... | $180 | $0 | Feb 11, 2002 |
| Jul 25, 2000 | 34261316N | RESOLVE | Non-Hazardous | FAILURE TO PROVIDE ELEVATOR LANDING SIGNS "IN CASE OF FIRE, USE STAIRSUNLESS OTHERWISE INSTRUCTED" ON FLOORS 2,4,5. F... | $0 | $0 | Oct 2, 2000 |
| Jul 25, 2000 | 34261315L | RESOLVE | Non-Hazardous | FAILURE TI FILE A REPORT OF COMPLIANCE WITH LOCAL LAW 16/84, CERTIFYING TO THE INSTALLATION OF REQUIRED FIRE PROTECTI... | $400 | $0 | Mar 19, 2001 |
| Jun 11, 1999 | 38086018P | RESOLVE | Non-Hazardous | 57O2,58O2,59O2,17M7,14M7,8V1,74O2,74M7,35P7. -74 CLEAN CAR TOP, -74 PROVIDE CAPACITY PLATE IN CAR | $0 | $0 | Aug 2, 1999 |
| Mar 15, 1999 | 38083299R | RESOLVE | Non-Hazardous | 17I11,11Q3,1B11,28H12,9M7,73U16,31D6,36W7. -17 PROVIDE GLASS FOR CAR DOOR; 1ST FL; 5TH FL, -9 PROVIDE SECOND GIB, -73... | $2,500 | $0 | Jul 12, 1999 |
| Feb 5, 1999 | 38082814H | RESOLVE | Non-Hazardous | 46H12,50Y14,11Q3,28H12,57O2. 46-REPLACE HOIST CABLES. 50-SEAL OIL LEAK AT MACHINE. 11-INSTALL GUARD AT LIGHT (IN CAR)... | $180 | $0 | May 24, 1999 |
| Oct 23, 1998 | 34183768N | RESOLVE | Hazardous | FAILURE TO MAINTAIN EXTERIOR BLDG WALL. DEFECT IS: MASONRY COPING AT NE PARAPET WALL BROKEN & MISSING SECTION APPROX ... | $800 | $0 | Dec 14, 1998 |