ECB violations
1914-1926 Nostrand Avenue, Brooklyn • Block 05216 • Lot 0060
89 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Feb 20, 2024 | 39106382N | ACTIVE | CLASS - 2 | REPAIR WHEELHOUSE DOOR LOCK. ADJUST DOOR CLOSING TIME. REPAIR CAR PHONE. SEAL HOIST MACHINE LEAKS. OIL LEAKING ONTO B... | $3,125 | $3,125 | May 1, 2024 |
| May 13, 2021 | 39041142J | RESOLVE | CLASS - 2 | PERFORM BRAKE MAINTENANCE AND PROVIDE BRAKE TAG WITH FULL DATE ENTERED MM/DD/YEAR., PROVIDE MOTOR ROOM LIGHT GUARD., ... | $1,563 | $1 | Nov 1, 2021 |
| Dec 31, 2019 | 38272833K | ACTIVE | CLASS - 2 | 37M07, 70O02, 40O02: 37-M-07 PROVIDE LADDER/STAIRS TO ACCESS OVERHEAD ROOM SAFELY, 70-O-02 CLEAN PIT, 40-O-02 CLEAN M... | $6,250 | $6,250 | Jan 28, 2021 |
| Dec 12, 2018 | 38266850L | RESOLVE | CLASS - 2 | 37M07,57BB07,56Y13,56O02,59BB07,77Q07. 37M07-PROVIDE STAIRS TO ACCESSOVERHEAD; 57BB07-SERVICE FIRE EXTINGUISHER AND P... | $655 | $0 | Mar 18, 2019 |
| Dec 13, 2016 | 38251469K | ACTIVE | CLASS - 1 | 52K11. HOIST CABLES RUSTY, REPAIR. | $1,000 | $0 | Jun 28, 2017 |
| Sep 6, 2016 | 38245867P | RESOLVE | CLASS - 2 | 59M7,60Q07,67X10,80M7. 59M-BRAKE TAG MISSING (PROVIDE) 60Q7-LIGHTING MACHINE SPACE UNGUARDED (PROVIDE. 67X10-CAR PHON... | $0 | $0 | Apr 10, 2017 |
| Jun 14, 2016 | 38243434K | RESOLVE | CLASS - 1 | 97X10 FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER.SERVICE EQUIPMENT ELEVAOTR AS PER BC 3001.2 AND 27-987. D... | $1,000 | $0 | Aug 17, 2016 |
| Mar 22, 2016 | 35140397J | RESOLVE | CLASS - 1 | WORK WITHOUT PERMIT. TIME OF INSPECTION 1:30PM ABOVE THE DATE. AT TIMEOF INSPECTION I OBSERVED ILLEGAL GAS CONNECTION... | $0 | $0 | May 9, 2016 |
| Jan 7, 2016 | 35148528R | RESOLVE | CLASS - 2 | SEC. 28-201.2 FAILURE TO MAINTAIN SIDEWALK SHED AS REQUIRED BY CODE. NOTE: AT TIME OF INSPECITON,SIDEWALK SHED ERECTE... | $0 | $0 | Feb 29, 2016 |
| Jan 7, 2016 | 35148527P | RESOLVE | CLASS - 2 | SEC. 3307.6.5 FAILURE TO MAINTAIN ADEQUATE ILLUMINATION BENEATH SIDEWALK SHED AS REQUIRED BY CODE. NOTE: SIDEWALK SHE... | $0 | $0 | Feb 29, 2016 |
| Oct 28, 2015 | 32075859H | ACTIVE | CLASS - 2 | B254,50,50A,50B,50C. 50-STORAGE AND DEBRIS BLOCKING OUTSIDE FRESH AIRINLET TO BOILER ROOM; 50A-EXPOSED WOOD IN BOILER... | $250 | $0 | Dec 14, 2015 |
| Jun 1, 2015 | 38236457H | RESOLVE | CLASS - 2 | 05J01,100M07,67L10,05M07,52Q03,37T07,05R09,61G11,56Y13,52K11,52B14,16I10,16R09,70O02. 05J-GAP AT STRIKE POST; 100M-IN... | $500 | $0 | Jul 20, 2015 |
| Mar 4, 2015 | 32075081X | RESOLVE | CLASS - 2 | B254,15,16,50A,50B,50C,50D,50E. 50A-NO SMOKE ALARM 30GPH; 50B-PIGTAIL TO BE BRASS; 50C-OIL SUPPLY PUMP TO HAVE GUARD;... | $500 | $0 | Apr 20, 2015 |
| Jan 7, 2015 | 32074893R | RESOLVE | CLASS - 2 | B254,28A,28B,28C,50A. 50A-REPLACE PLUGGED TUBES. | $500 | $0 | Sep 14, 2015 |
| May 17, 2014 | 35010934K | ACTIVE | CLASS - 2 | FAILURE TO MAINTAIN BLDG WALL(S) OR APPURTENANCES-NOTED:@ TIME OF INSPOBSERVED CRACKS BATH VERTICAL,& STEPPED FORMING... | $500 | $0 | Nov 10, 2014 |
| Mar 10, 2014 | 35038073M | RESOLVE | CLASS - 2 | UNAPPROVED/UNSAFE/UNSUITABLE ELECTRICAL EQUIPMENT,APPARATUS,MATERIAL,DEVICES,APPLIANCES OR WIRING IN USE.UNDER CANOPY... | $400 | $0 | Nov 14, 2014 |
| Mar 10, 2014 | 35038071Z | RESOLVE | CLASS - 2 | ELECTRICAL WORK W/O A PERMIT. BRANCH CIRCUIT,FIXTURES,FRONT OF BLDG UNDER CANOPY. OBTAIN A PERMIT | $400 | $0 | Nov 14, 2014 |
| Feb 19, 2014 | 35038739J | RESOLVE | CLASS - 2 | UNAPPROVED UNSAFE UNSUITALBE ELECTRICAL EQUIPMENT DEVICES MATERIALS APPARATUS APPLIANCES OR WIRING IN USE. (4) 8' FLU... | $400 | $0 | Apr 7, 2014 |
| Feb 19, 2014 | 35038740R | ACTIVE | CLASS - 2 | FAIL TO PROVIDE EFFECTIVE ELECTRICAL CONTINUITY FOR METAL RACEWAYS/ENCLOSURES/CABLE ARMOR. RACEWAY FEEDING FLUORESCEN... | $600 | $0 | Apr 8, 2014 |
| Feb 19, 2014 | 35038741Z | ACTIVE | CLASS - 1 | OPEN WIRING UNDER AWNING. ELECTRICAL WIRING 8' FIXTURES UNDER AWNING NOT PROVIDED IN RACEWAY. REMEDY: COMPLY W/EC CODE. | $1,600 | $0 | Apr 8, 2014 |
| Jan 8, 2014 | 35081219J | ACTIVE | CLASS - 2 | FAILURE TO MAINTAIN BLDG WALLS OR APPURTENANCES.NOTED @ REAR OF BLDG EXP 3SLIGHT HAIRLING CRACKS OBSERVED @GROUND LEV... | $500 | $0 | Feb 24, 2014 |
| Jul 13, 2013 | 35050574M | RESOLVE | CLASS - 1 | FAILURE TO COMPLY W/THE COMMISSIONER'S ORDER CONTAINED IN NOV #34893444N ISSUED ON 1.13.11 FOR WORK W/O A PERMIT - IN... | $12,000 | $0 | Sep 9, 2013 |
| May 17, 2013 | 35060154P | RESOLVE | CLASS - 1 | FAILURE TO COMPLY W/COMMISSIONER'S ORDER CONTAINED IN NOV#34893444N ISSUED ON 1/13/11. (INSTALLING GAS & PLUMBING LIN... | $24,000 | $0 | Jul 1, 2013 |
| Mar 29, 2013 | 38226142Y | RESOLVE | CLASS - 2 | 09B07,16I10,40P07. PEOPLE COMPLAINING OF SADDLE,WHERE IT IS CUT,PROVIDE FILLER OR REPLACE W/LONGER SADDLE IF POSSIBLE... | $2,500 | $0 | May 13, 2013 |
| Mar 22, 2013 | 38225513J | RESOLVE | CLASS - 2 | 16D10,70O02,16##,16B04. 16D10-BASEMENT DORO LOCK RUBBING AGAINST ELEVATOR; 16B04-PATCH HOLE ON BASEMENT DOOR; 16##-RE... | $2,500 | $0 | May 6, 2013 |
| Jan 3, 2013 | 35002612H | RESOLVE | CLASS - 1 | FAILURE TO COMPLY W/THE COMMISSIONER'S ORDER TO CORRECT CONDITIONS CITED IN NOV #34893444N ISSUED ON 1.13.11 FOR INST... | $24,000 | $0 | Feb 25, 2013 |
| Oct 23, 2012 | 32072515K | RESOLVE | CLASS - 2 | B254,6A,15,34B,50,50A,B. 50- GAS PIOLITE REGULATOR MISSING VEUT LIMMITER. 50A- OIL PUMP MISSING BELT GUARD. 50B- GAS ... | $2,500 | $0 | Dec 10, 2012 |
| Jul 24, 2012 | 34988092K | RESOLVE | CLASS - 1 | FAILURE TO COMPLY W/THE COMMISSIONER'S ORDER CONTAINED IN NOV #34893444N ISSUED ON 1.13.11 FOR WORK W/O PERMIT - CELL... | $24,000 | $0 | Sep 10, 2012 |
| Mar 10, 2012 | 32071778H | RESOLVE | CLASS - 3 | B354,16,5B,50A,B,C,D,E. 50A- BRASS PIGTAIL REQUIRED FOR PRESSURE GAUGE. 50B- GUARD MISSING ON OIL SUPPLY PUMP. 50C- B... | $500 | $0 | Apr 30, 2012 |
| Mar 1, 2012 | 34964320R | RESOLVE | CLASS - 1 | FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER CONTAINED IN NOTICE OFVIOLATION #348934 ISSUED ON 1-13-11. THE RESPON... | $12,000 | $0 | Apr 16, 2012 |
| Nov 15, 2011 | 32071532H | RESOLVE | CLASS - 3 | B354,50A,50B,50C, 50A-REMOVE WASTE OIL FROM BOILER ROOM 50B-LABE JUEL CUT OFF SWITCH OUTSIDE OF BOILER ROOM DOOR 50C-... | $200 | -$23 | Jan 9, 2012 |
| Sep 13, 2011 | 34961383K | RESOLVE | CLASS - 1 | FAILURE TO COMPLY WITH THE COMMISSIONERS ORDER CONTAINED IN NOTICE OF VIOLATION# 34893444N ISSUED ON 01/13/11. FOR WO... | $12,000 | $0 | Oct 31, 2011 |
| Jul 28, 2011 | 34960565R | RESOLVE | CLASS - 1 | FAILURE TO COMPLY W/THE COMMISSIONER'S ORDER CONTAINED IN NOTICE OF VIOLATION #34893444N ISSUED ON 1/13/11. REMEDY: C... | $2,400 | $0 | Nov 14, 2011 |
| May 26, 2011 | 34919051P | RESOLVE | CLASS - 1 | FAILURE TO COMPLY W/ THE COMM ORDER TO CORRECT VIOLATING CONDITIONS NOTED IN ECB NOV#34893444N FOR WORK W/O A PERMIT ... | $12,000 | $0 | Jul 11, 2011 |
| Apr 1, 2011 | 34905891K | RESOLVE | CLASS - 3 | FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER.FRONT ENTRANCE-1)MISSING RAILINGS @ EXTERIOR FRONT ENTRANCE LANDING... | $500 | $0 | May 16, 2011 |
| Mar 17, 2011 | 34905706J | RESOLVE | CLASS - 1 | FAILURE TO COMPLY W/AN ORDER OF THE COMMISSIONER. RESPONDENT FAILED TOCORRECT CONDITIONS CITED ON ECB VIO 34893444N F... | $12,000 | $0 | May 9, 2011 |
| Jan 13, 2011 | 34893444N | RESOLVE | CLASS - 1 | WORK W/O PERMIT; ILLEGAL WORK NOTED AT CELLAR 1 CLASS'A' APT W/3PCS BATHROOM RESIDENTIAL SINK,TOILET,SHOWER,WATER,WAS... | $16,000 | $0 | Feb 28, 2011 |
| Jan 13, 2011 | 34893443L | RESOLVE | CLASS - 2 | RESIDENCE ALTERED FOR OCCUPANCY AS A DWELLING FOR MORE THAN THE LEGALLY APPROVED # OF FAMILIES.NOTED:CELLAR LEVEL CLA... | $0 | $0 | Aug 8, 2011 |
| Oct 20, 2010 | 32069716J | RESOLVE | CLASS - 2 | 16/50A/50B/50C/50D/50E 50A-REMOVE ALL STORAGE 50B-REMOVED ALL FLAMABLES 50C-OPEN CONTAINERS OF FUEL OIL 50D-NO TEST C... | $2,500 | $0 | Dec 13, 2010 |
| Apr 6, 2010 | 32068459N | RESOLVE | CLASS - 3 | 15,21C,34B,40,48A,50A-REMOVE ALL STORAGE FROM BOILER ROOM. | $100 | $0 | Jun 7, 2010 |
| Feb 24, 2010 | 38208873Z | RESOLVE | CLASS - 2 | 58BB5.80B14.20R11.70O2.56Y2. | $2,500 | $0 | Apr 19, 2010 |
| Dec 14, 2009 | 32067952M | RESOLVE | CLASS - 3 | B354 15.16.50A.50B.50C.50D 50A REMOVE ALL STORAGE 50B ALL FLAMABLES 50C BO TEST CHAINS ON RELIEF VALVES 50D TRAIN EMP... | $500 | $0 | Feb 8, 2010 |
| Oct 27, 2009 | 32067356X | RESOLVE | CLASS - 3 | B354 15.50A.50B.50A FLUE PIPE NOT PROPERLY SEALED TO CHIMNEY 50B FLUE PIPE NEED SUPPORT | $500 | $0 | Dec 21, 2009 |
| Sep 17, 2009 | 34807307N | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN BLDG WALLS OR APPURTENANCES. NOTED: AT ROOF LEVEL TO 6TH FLR HAIR LINE MORTAR CRACKS EXIST IN SEV... | $250 | $0 | Nov 9, 2009 |
| Mar 18, 2009 | 38202102N | RESOLVE | CLASS - 2 | 16E10.16H11.42G11.59Y02.56Y02.56Y13.71L10.32H10.10H11.39O02.34O02.40R09.16J01.16H11 HATCH DOOR PIVOTS WORN REPLACE 40... | $250 | $0 | Feb 1, 2010 |
| Mar 16, 2009 | 32065922M | RESOLVE | CLASS - 3 | B354 50A.50B.50C 50A FLUE PIPE NOT PREOPERLY SEALED TO CHIMNEY 50B SEALED AROUND CLEAN OUT DOOR ON CHIMNEY BASE 50C B... | $500 | $0 | Jan 4, 2010 |
| Oct 11, 2008 | 32060891X | RESOLVE | CLASS - 2 | B254,50A,B,C,D,E,F.50A-HOLES IN BOILER ROOM WALLS & CEILING.50B-BOILERROOM FIRE DOOR DEFECTIVE NOT SELF CLOSING.50F-L... | $2,500 | $0 | Dec 1, 2008 |
| Jul 31, 2008 | 34697606Z | ACTIVE | CLASS - 1 | SEC. 28-201.1. FAILURE TO COMPLY W/COMM'S ORDER TO CORRECT VIO #34640350R FOR WORK W/O PERMIT @ CELLAR BUILT 1) ILLEG... | $8,000 | $0 | Sep 22, 2008 |
| Mar 31, 2008 | 34640350R | RESOLVE | Hazardous | WORK W/O A PERMIT. WORK NOTED: CELLAR CLASS A APT ERECTED INTERIOR PARTITION CREATING 3 PC BATHROOM, FULL KITCHEN W/G... | $2,500 | $0 | May 19, 2008 |
| Mar 31, 2008 | 32056263N | RESOLVE | Non-Hazardous | B4A, 50A,50B,50C,50D,50E,50F: 50A-REMOVE WASTE OIL FROM BOILER ROOM 50B-BOILER ROOM NOT A STORAGE ROOM. 50C-FLUE PIPE... | $2,500 | $0 | Jun 2, 2008 |