ECB violations
194 Minna Street, Brooklyn • Block 05302 • Lot 0080
20 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Jan 7, 2025 | 39535690K | RESOLVE | CLASS - 1 | BC 3314.1. FAILURE TO MAINTAIN TARP INSTALLED ON SUPPORTED SCAFFOLD. I OBSERVED WHITE COVERING TARP ON SUPPORTED SCAF... | $0 | $0 | Sep 16, 2025 |
| Nov 26, 2024 | 39534731N | RESOLVE | CLASS - 1 | OBSERVED SUPPORTED SCAFFOLD INSTALLED @EXPO#1 WITH A WHITE TARP NOT FULLY ENCLOSING THE SCAFFOLD. THE TARP IS CAUSING... | $0 | $0 | Sep 18, 2025 |
| Nov 22, 2024 | 39534643N | RESOLVE | CLASS - 2 | IN VIOLATION OF CODE 3314.8.2. RESPONDING TO A COMPLAINT MADE FROM ADJACENT PROPERTY. I OBSERVED A WHITE TARP COVERIN... | $2,500 | $2,500 | Aug 4, 2025 |
| Nov 1, 2024 | 39129186H | RESOLVE | CLASS - 2 | AT TIME OF INSPECTION OBSERVED AT REAR OF THE BUILDING CONSTRUCTION FENCE PANELS LEANING OUTWARD AT TWO LOCATIONS AND... | $1,000 | $1,000 | Jan 15, 2025 |
| Jul 23, 2024 | 39530755J | RESOLVE | CLASS - 2 | BC 3303.1 SAFEGUARDS AND MAINTENANCE OF SITE. OBSERVED NEW WATERPROOFING AT THE ROOF LEVEL. ALSO OBSERVED EVIDENCE OF... | $625 | $625 | Apr 8, 2025 |
| Jul 15, 2024 | 39530542X | RESOLVE | CLASS - 2 | OBSERVED STANDING WATER AT ROOF LEVEL, INADEQUATE WATER PROTECTION AT ROOF LEVEL CAUSED DAMAGE TO ADJOINING BUILDING ... | $0 | $0 | Feb 11, 2025 |
| May 6, 2024 | 39528302Y | RESOLVE | CLASS - 1 | OBSERVED THAT STRUCTURE WORK AND EXTERIOR WORK FOR BULKHEAD ARE COMPLETED. UPON REVIEW OF THE DEPARTMENT RECORDS, OBS... | $0 | $0 | Jul 8, 2025 |
| May 6, 2024 | 39528310Y | RESOLVE | CLASS - 2 | OBSERVED ACTIVE SITE AND FRONT MAIN DOOR IS LOCKED,WITH ONE WORKER PERFORMING INTERIOR WORK AT BULKHEAD ROOF, UPON CA... | $0 | $0 | Jul 8, 2025 |
| May 3, 2024 | 39528253R | RESOLVE | CLASS - 1 | MISSING ROOF PROTECTION BC-3309.10.ATOI AT THE ACTIVE CONSTRUCTION SITE, WORK AT ROOF LEVEL I OBSERVED MISSING PROTEC... | $0 | $0 | Jan 23, 2025 |
| May 3, 2024 | 39528256M | RESOLVE | CLASS - 2 | ATOI AT THE ACTIVE CONSTRUCTION SITE I OBSERVED A LARGE AMOUNT OF DEBRIS THROUGHOUT THE ENTIRE JOB SITE. THIS CREATES... | $0 | $0 | Jul 10, 2024 |
| May 3, 2024 | 39528255K | RESOLVE | CLASS - 1 | NO DESIGN DRAWING FOR TEMPORARY PLATFORM-BC.3301.6.ATOI I OBSERVED UNSAFE TEMPORARY PLATFORM AT THE STAIRS 2ND FLOOR.... | $0 | $0 | Jan 23, 2025 |
| May 3, 2024 | 39528254Z | RESOLVE | CLASS - 1 | ATOI AT THE ACTIVE CONSTRUCTION SITE, CURRENTLY WORKING AT ROOF LEVEL BULKHEAD I OBSERVED MISSING GUARDRAILS AROUND T... | $5,000 | $5,000 | Jan 23, 2025 |
| Apr 22, 2024 | 39527823P | RESOLVE | CLASS - 2 | BC 3301.9.3 MISSING FENCE SIGNS AT CONSTRUCTION / DEMOLITION SITE FOR 1 / 2 / 3 FAMILY DWELLING UNDER CONSTRUCTION. A... | $1,250 | $1,250 | Jun 26, 2024 |
| Mar 5, 2024 | 39526138M | RESOLVE | CLASS - 1 | ATOI I OBSERVED INSTALLED Q-DECKING AT REAR YARD EXP. # 3. INSTALLED Q-DECKING COVERING THE ENTIRE BACKYARD AND WAS I... | $625 | $625 | Feb 18, 2025 |
| Dec 11, 2023 | 39523987N | RESOLVE | CLASS - 2 | OBSERVED CONSTRUCTION FENCE AT ALL EXPOSURES OF THE BUILDING INSTALLED NOT AS PER CODE. MISSING VIEWING PANELS AT EXP... | $1,000 | $0 | Feb 14, 2024 |
| Dec 11, 2023 | 39523986L | RESOLVE | CLASS - 2 | AT THE TIME OF INSPECTION, AN ACTIVE JOB SITE WAS OBSERVED. UPON KNOCKING ON THE FENCE AND SHOUTING, A WORKER CAME OU... | $2,500 | $0 | Feb 14, 2024 |
| Dec 8, 2023 | 39523951L | RESOLVE | CLASS - 2 | FAILURE TO PROVIDE OVERHEAD PROTECTION -- AT THE TIME OF MY INSPECTION OF A 2 STORY BUILDING UNDER ALTERATION, I OBSE... | $5,000 | $0 | Jul 16, 2024 |
| Mar 8, 2023 | 39081011X | RESOLVE | CLASS - 1 | VIOLATION ISSUED FOR WORKING WHILE ON NOTICE OF A STOP WORK ORDER. AT TIME OF INSPECTION OBSERVED WORKERS POURING CON... | $5,000 | $0 | May 17, 2023 |
| Jul 18, 2022 | 39066084L | RESOLVE | CLASS - 2 | WORK WITHOUT PERMIT. OBSERVED NEWLY ERECTED ADDITION ATTACHED TO THE BACK OF HOUSE. ADDITION IS METAL FRAME WITH META... | $1,250 | $0 | Nov 23, 2022 |
| Jul 18, 2022 | 39066127M | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN BUILDING IN A CODE-COMPLIANT MANNER. OBSERVED AT FRONT EXPOSURE #1 ROOF IN DISREPAIR WITH DETACHE... | $312 | $0 | Dec 21, 2022 |