1443-1449 39 Street, Brooklyn
Brooklyn • Block 05347 • Lot 0058 • Zip: 11218
Condition
What the city currently has open against this building, counted from its own records.
Address
Land use and zoning
Building
Latest assessment
Neighborhood
The area this lot falls inside, and the commute Hoodkit measures from it.
Getting around
Estimated 4 days ago- Downtown Brooklyn 35 min 4 walking, 31 riding
- Fulton Street 41 min 4 walking, 37 riding
- Union Square 44 min 4 walking, 40 riding
- Times Square 49 min 4 walking, 45 riding
- Penn Station 51 min 4 walking, 47 riding
- Grand Central 52 min 4 walking, 48 riding
Around this address
Transit and places within 0.5 miles of the lot.
Getting out
Subway
Ferry
Bus
Citi Bike
Places nearby
Shingara
No description yet
Korner Pizza
No description yet
Mexican Grocery & Deli Corp.
No description yet
Shashlik House
Kebabs, pierogi, churrasco & other Uzbeki staples are served in a simple eatery with a large coal grill.
Ghoroa Sweets and Restaurant
No description yet
Madhuban Sweets & Restaurant
No description yet
Abdullah
No description yet
10am Breakfast Bar
Sleek counter serves to offer salads, sandwiches & breakfast classics like avocado toast & shakshuka.
Activity
Sales, filings, permits and violations from every dataset, in one order.
2026
-
Alteration Type I
Vertical Extension to Existing Two (2) Story Building. Convert Existing Business School to Yeshiva (Religious School).
2025
-
DOB violation Nov 14, 2025
LBLVIO-LOW PRESSURE BOILER BOILER REQUIRED
VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION
-
CLASS - 2
AT TIME OF INSPECTION, I OBSERVED APPROXIMATELY 15 WORKERS PERFORMING CONSTRUCTION ACTIVITIES ON SITE FOR WHICH NO AF...
-
CLASS - 2
AT TIME OF INSPECTION, UPON REVIEWING BIS / DOBNOW, NO PERMIT WAS FOUND FOR PUMP JACK SCAFFOLDING INSTALLED AND IN US...
-
CLASS - 2
AT TIME OF INSPECTION, AS PER CODE SECTION BC 3301.6, NO ENGINEER DESIGN DRAWINGS WERE PROVIDED UPON REQUEST FOR PUMP...
-
CLASS - 2
AT TIME OF INSPECTION, I OBSERVED WORKERS WORKING ON PUMP JACK SCAFFOLDING AT EXPOSURE #4 WITHOUT LIFE LINE OR THE RE...
-
CLASS - 2
OBSERVED, NO TPP POSTED OR PRESENTED DURING INSPECTION, THOUGH THE SCHOOL IS ACTIVE AND OCCUPIED DURING CONSTRUCTION ...
-
CLASS - 2
OBSERVED PUMP JACKS OBSERVED AT EXPOSURES 1 AND 4, NOT IN USE, TIED OFF AND SECURED WITH NETTING. NO DOCUMENTATION PR...
2024
2023
-
DOB violation Jun 30, 2023
LBLVIO-LOW PRESSURE BOILER BOILER REQUIRED
VIOLATION ISSUED-FAILURE TO FILE 2020 EXTERNAL LOW PRESSURE INSPECTION
-
DOB violation Jun 20, 2023
LBLVIO-LOW PRESSURE BOILER BOILER REQUIRED
VIOLATION ISSUED-FAILURE TO FILE 2019 EXTERNAL LOW PRESSURE INSPECTION
-
DOB violation Apr 25, 2023
LBLVIO-LOW PRESSURE BOILER BOILER REQUIRED
VIOLATION ISSUED-FAILURE TO FILE 2022 EXTERNAL LOW PRESSURE INSPECTION
-
DOB violation Apr 25, 2023
LBLVIO-LOW PRESSURE BOILER BOILER REQUIRED
VIOLATION ISSUED-FAILURE TO FILE 2022 EXTERNAL LOW PRESSURE INSPECTION
2021
-
Place of Assembly
2019
-
Alteration Type II
TO CREATE A NEW ACCESSIBLE TOILET IN RELATION TO PUBLIC ASSEMBLY JOB # 321637975
2018
-
DOB violation Apr 6, 2018
LBLVIO-LOW PRESSURE BOILER BOILER REQUIRED
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2016 INSPECTION REPORT
2017
-
Alteration Type II
FILING FOR COMMERCIAL EXHAUST SYSTEM, FIRE SUPPRESSION SYSTEM AND FIRE SUPPRESSION SYSTEM SHUT OFF VALVE, THERE IS NO...
2014
-
Place of Assembly
The most recent 6 events from each dataset, so no one source takes the axis. Each tab holds the full record.
Property Contacts
Contact information aggregated from multiple government sources
Building Permits
Owner information from Department of Buildings filings
Recent Building Permits
Owner information from recent DOB NOW filings
Deed Records
Parties from ACRIS deed and mortgage records
Property Records
Owner information from assessment and PLUTO records