| Apr 17, 1998 | 38072193P | RESOLVE | Non-Hazardous | 37H75U 37-CONTACTS ON CONTROLLER NEED TO BE REPLACING 45-TAG ON GOV OUT DATED. | $0 | $0 | Jun 8, 1998 |
| Jul 8, 1997 | 38061676X | RESOLVE | Non-Hazardous | 75R35O74L73O74L 74-REPLACE BROKEN SHACKLE SPRING (CAR TOP) 74-L REPLACE SELECTOR CONTACTS ON LEVELLING RING (NO CARBO... | $1,000 | $0 | Sep 29, 1997 |
| Jul 8, 1997 | 38061300H | RESOLVE | Non-Hazardous | 74L73O74L46L 74-L TIGHTEN ALL GUIDE SHOE BOLTS 73-CLEAN ENTIRE DEVICE REPLACE COUNTER WEIGHT BUFFER SPRING. | $1,000 | $0 | Sep 29, 1997 |
| Jul 8, 1997 | 38061678J | RESOLVE | Non-Hazardous | 35O73O74H39H74 74-REPLACE WORN BRUSHES ON HOIST MOTOR 74-PROVIDE CORRECT ID NUMBERS IN MOTOR ROOM. | $1,000 | $0 | Sep 29, 1997 |
| Jul 1, 1997 | 38061298H | RESOLVE | Non-Hazardous | 35O,74L,57O,40O,75R,50O,74M, #74L-COUNTER WEIGHT LANDS WHEN CAR IS LEVEL WITH TOP FLOOR #74M-PROVIDE LOCK NUT ON BRAK... | $500 | $0 | Aug 18, 1997 |
| Jul 1, 1997 | 38061296Y | RESOLVE | Non-Hazardous | 74L,74#35O, #74L-REPAIR FIRE PROOFING UNDER CAR PLATFORM #74#CLEAN BRAKE DRUM. | $100 | $0 | Aug 18, 1997 |
| Jul 1, 1997 | 38061297X | RESOLVE | Non-Hazardous | 74L,50O,74B,35O,74#,74D, #74L-REPAIR FIRE PROOFING UNDER CAR PLATFORM #74B- REPLACE COTTER PIN ON BRAKE PIN (TO SMALL... | $100 | $0 | Aug 18, 1997 |
| Jun 8, 1997 | 38061677H | RESOLVE | Non-Hazardous | 74D74L34L74D35O 74-D SECURE WIRING UNDER CAR 74-L REPAIR FIRE PROOFINGUNDER CAR 34-REPAIR TRAVELLING CABLE UNDER CAR ... | $1,000 | $0 | Sep 29, 1997 |
| Mar 23, 1995 | 38047320Y | RESOLVE | Non-Hazardous | 05X, 22D, 37G, 50Y, 53M. 05-REPLACE WORN CAR DOOR SADDLE. | $0 | $0 | May 8, 1995 |
| Mar 23, 1995 | 38047321X | RESOLVE | Non-Hazardous | 07L, 11Q, 22D, 53M. | $0 | $0 | May 8, 1995 |
| Aug 3, 1994 | 34114662X | RESOLVE | Hazardous | SUPERVISION OR USE OF RIGGING WITHOUT A MASTER RIGGERS LICENSE: TWO POINT SUSPENSION SCAFFOLD ERECTED AT SOUTH SIDE O... | $0 | $0 | Aug 29, 1994 |
| Aug 3, 1994 | 34114661Y | RESOLVE | Non-Hazardous | FAILURE TO MAINTAIN EXTERIOR BUILDING WALL. DEFECT IS: CONCRRETE BEAMSLINTELS, COLUMNS AND WINDOWS SILL CRACKED SPALL... | $175 | $0 | Feb 6, 1995 |
| Sep 22, 1993 | 34087636L | RESOLVE | Non-Hazardous | FAILURE TO PROVIDE ADEQUATE EMERGENCY POWER EXIT LIGHT IN TENANTS SPACE THROUGHOUT FLOORS FAILURE TO PROVIDE EMERGENC... | $0 | $0 | Dec 20, 1993 |
| Apr 30, 1993 | 38032939X | RESOLVE | Non-Hazardous | 35P,(35) UNABLE TO GAIN ACCESS TO COMPLETE INSPECTION | $0 | $0 | Jul 12, 1993 |
| Apr 27, 1993 | 38032934R | RESOLVE | Non-Hazardous | 35P UNABLE TO GAIN ACCESS TO COMPLETE INSPECTION | $0 | $0 | Jun 28, 1993 |
| Apr 27, 1993 | 38032933P | RESOLVE | Non-Hazardous | 35P | $0 | $0 | Jun 28, 1993 |
| Apr 27, 1993 | 38032931L | RESOLVE | Non-Hazardous | 35P UNABLE TO GAIN ACCESS TO COMPLETE INSPECTION | $0 | $0 | Jun 28, 1993 |
| Apr 27, 1993 | 38032932N | RESOLVE | Non-Hazardous | 35P UNABLE TO GAIN ACCESS TO COMPLETE INSPECTION | $0 | $0 | Jun 28, 1993 |
| Mar 9, 1993 | 34079387J | RESOLVE | Non-Hazardous | FAILURE TO PROVIDE EMERGENCY POWER EXIT LIGHTS IN CORRIDOR AND STAIRCASE THROUGHOUT BLDGS FAILURE TO PROVIDE DIRECTIO... | $1,500 | $0 | May 24, 1993 |
| Aug 12, 1992 | 34072876Z | RESOLVE | Non-Hazardous | FAILURE TO PROVIDE ADEQUATE LANDING SIGNS(ELEVATOR BANK NOT SHOWN) FAILURE TO PROVIDE FLOOR NUMBER SIGNS 3' FAILURE T... | $0 | $0 | Sep 28, 1992 |
| Jul 15, 1992 | 38025555L | RESOLVE | Non-Hazardous | 18R,73#, #18 REPLACE INTERLOCK FOR MANDATE ONE AS ADMINISTRATION CODE. #73 PERFORM 5 YEAR TEST AND FILE FORM ELV # 3 | $200 | $0 | Oct 5, 1992 |
| Jul 15, 1992 | 38025554J | RESOLVE | Non-Hazardous | 18R,73#, #18 PROVIDE MANDATE INTERLOCK- #73 PERFORM 5 YEAR TEST AND FILE FORM ELV#3 | $200 | $0 | Oct 5, 1992 |
| Jul 14, 1992 | 38025552X | RESOLVE | Non-Hazardous | 73#,73R,18R,73#, #73 CHANGE OF OPERATION, USING ELEV FROM 1ST FLOOR TO 3RD FLOOR, FINAL LIMIT ON 3RD FLOOR, THEN USIN... | $350 | $0 | Nov 9, 1992 |
| Jul 14, 1992 | 38025553H | RESOLVE | Non-Hazardous | 18R,73#, #18 PROVIDE MANDATE INTERLOCKS #73 PERFORM 5 YEAR TEST AND FILE FORM 3 ELV | $200 | $0 | Oct 5, 1992 |
| Dec 11, 1991 | 32009195Z | RESOLVE | Unknown | 36 | $125 | $0 | Feb 24, 1992 |
| Oct 7, 1991 | 38019332N | RESOLVE | Non-Hazardous | 73M,(73) FIVE YEAR TEST. PROPER TAG AND FILE ELV 3 FORM | $0 | $0 | Jan 13, 1992 |
| Oct 7, 1991 | 38019333P | RESOLVE | Non-Hazardous | 73M,74M,(73) FIVE YEAR TEST. PROPER TAG AND FILE ELV3 FORM (74) CERTIFICATE OF INSPECTION AND LOC. OF ELEV. | $0 | $0 | Jan 13, 1992 |
| Oct 7, 1991 | 38019334R | RESOLVE | Non-Hazardous | 73M,(73) FIVE YEAR TEST. PROPER TAG AND FILE ELV 3 FORM | $0 | $0 | Jan 13, 1992 |
| Oct 7, 1991 | 38019335Z | RESOLVE | Non-Hazardous | 73X PLACE OUT OF ACTIVE SERVICE (DISMANTLE) OR PERMANENTLY DISCONTINUE (REMOVE) | $0 | $0 | Jan 13, 1992 |
| Oct 7, 1991 | 38019336K | RESOLVE | Non-Hazardous | 73X PLACE OUT OF ACTIVE SERVICE (DISMANTLE) OR PERMANENTLY DISCONTINUE (REMOVE) | $0 | $0 | Jan 13, 1992 |
| Sep 8, 1988 | 32000429L | RESOLVE | Non-Hazardous | REPLACE PRESENT SAFETY VALVE WITH 100 PSI 3/4 ASME APPROVED SAFETY VALVE | $0 | $0 | Oct 24, 1988 |