ECB violations
1549 50 Street, Brooklyn • Block 05453 • Lot 0058
28 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Dec 10, 2019 | 35457036J | RESOLVE | CLASS - 2 | 3301.12 3301.12.3 FAILURE TO PROVIDE RECORDS OF PRE-SHIFT SAFETY MEETINGS. AT THE TIME OF INSPECTION OF A 4 STORY NEW... | $0 | $0 | Apr 15, 2020 |
| Oct 18, 2019 | 35461673Y | RESOLVE | CLASS - 2 | JOBSITE FENCE NOT CONSTRUCTED OR MAINTAINED PURSUANT TO SUBSECTION.NOTED:AT TIME OF MY INSPECTION OF A NEW 4 STORIE B... | $0 | $0 | Feb 19, 2020 |
| Sep 4, 2019 | 35452801P | RESOLVE | CLASS - 1 | FAILURE TO SAFEGUARD ALL PERSONS AND PROPERTY AFFECTED BY COSNTRUCTION OPERATIONS NO ROOF PROTETCION AT EXP 2 AND 4 A... | $0 | $0 | Jan 8, 2020 |
| Sep 4, 2019 | 35452800N | RESOLVE | CLASS - 1 | FAILURE TO INSTITUTE/MAINTAIN SAFETY EQUIPMENTS MEASURES OR TEMPORARY CONSTRUCTION NO GUARDRIALS AT TIEM FO INSPECTIO... | $2,500 | $0 | Jan 8, 2020 |
| Sep 4, 2019 | 35452802R | RESOLVE | CLASS - 1 | 3301.6=DESIGN SIZES AND CAPACITY OF AMTERIALS STRUCTURES TEMPORARY CONSTRUTCION AND EQUIPMENTS DEISGN DRAWING FOR TEM... | $625 | $0 | Jan 8, 2020 |
| Sep 4, 2019 | 35452804K | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN ADEQUATE HOUSEKEEPING PER SECTION REQUIRMENTS AT TIME OF INSPECTION AT AN ACTIVE JOBSITE NB 4 SAT... | $625 | $0 | Jan 8, 2020 |
| Sep 4, 2019 | 35452805M | RESOLVE | CLASS - 2 | STORAGE ON SIDEWALK SHED AT TIME OF INSPECTION AT AN ACTIVE JOBSITE NB 4 STORY BUILDING IT WAS OBSERVED THAT TH SWS A... | $625 | $0 | Jan 8, 2020 |
| Sep 4, 2019 | 35452803Z | RESOLVE | CLASS - 2 | 3314.4.8=UNSAFE SCAFFOLD SCAFFOLD HAS NOT NOT BEEN ERECTED AND MAINTAINED IN A SAFE MANNER SO AS NOT TO ENDANGER PUBL... | $0 | $0 | Jan 8, 2020 |
| Aug 16, 2019 | 39007866X | RESOLVE | CLASS - 1 | OWNER: EMPLOYER FAILED TO ENSURE EACH CONSTRUCTION OR DEMOLITION WORKER SUCCESSFULLY COMPLETED THE REQUIRED TRAINING ... | $0 | $0 | Jan 30, 2020 |
| Aug 16, 2019 | 39007865Y | RESOLVE | CLASS - 1 | PERMIT: EMPLOYER FAILED TO ENSURE EACH CONSTRUCTION OR DEMOLITION WORKER SUCCESSFULLY COMPLETED THE REQUIRED TRAINING... | $0 | $0 | Jan 30, 2020 |
| Jun 27, 2019 | 35431836M | RESOLVE | CLASS - 1 | PERMIT HOLDER FAILED TO ENSURE EACH WORKER SUCCESSFULLY COMPLETED THE REQUIRED TRAINING UNDER BC 3321.1 OBSERVED DELC... | $0 | $0 | Feb 20, 2020 |
| Jun 27, 2019 | 35431834Z | RESOLVE | CLASS - 1 | PERMIT HOLDER FAILED TO ENSURE EACH CONSTRUCTION OR DEMOLITION WORKER SUCCESSFULLY COMPELTED THE REQUIRED TRAINING UN... | $5,000 | $0 | Feb 21, 2020 |
| Jun 27, 2019 | 35431837Y | RESOLVE | CLASS - 1 | OWNER FAILED TO ENSURE EACH CONSTRUCTION OR DEMOLITON WORKER COMPLETEDREQUIED TRAINING UNDE BC 3321.1. OBSERVED DEL C... | $5,000 | $0 | Feb 21, 2020 |
| Jun 27, 2019 | 35431835K | RESOLVE | CLASS - 1 | OWNER FAILED TO ENSURE EACH CONSTRUCTION OR DEMOLITION WORKER SUCCESS FULLY COMPLETED REQUIRED TRAINING UNDER BC 3321... | $0 | $0 | Feb 20, 2020 |
| Jan 18, 2019 | 35381618L | RESOLVE | CLASS - 1 | 3309.10=FAILURE TO PROTECT ADJACENT PROPERTY/INADEQUAE ROOF PROTECTION.AT TIME OF INSPECTION AT AN ACTIVE FOUR(4) STO... | $0 | $0 | Jan 22, 2020 |
| Jan 18, 2019 | 35381619N | RESOLVE | CLASS - 1 | FAILURE TO SAFEGUARD ALL PERSONS AND PROPERTY AFFECTED BY CONSTRUCTION OPERATIONS.AT TIME OF INSPECTION ON ACTIVE JOB... | $0 | $0 | Jan 22, 2020 |
| Dec 19, 2018 | 35360681L | RESOLVE | CLASS - 2 | RESPONDENT FAILED TO MAKE THE PROPER NOTIFICATION FOR MOBILE CRANE AFTER MAY 1 2018 TO THE DEPT.AT TIME OF INSPECTION... | $5,000 | $0 | Apr 29, 2019 |
| Dec 13, 2018 | 35380332L | RESOLVE | CLASS - 2 | SITE SAFETY PLAN FOR JOBS THAT REQUIRE A PRIMARY CONSTRUCTION SUPER AT TIME OF INSPECTION ON A ACTIVE JOBSITE OF A 4 ... | $0 | $0 | Mar 20, 2019 |
| Dec 13, 2018 | 35380331J | RESOLVE | CLASS - 1 | WORK DOES NOT CONFORM TO APPROVED DESIGN DRAWINGS/PLANS. AT TIME OF INSPECTION ON A ACTIVE JOBSITE OF A 4 STORY BUILD... | $625 | $0 | Mar 20, 2019 |
| Dec 13, 2018 | 35380334P | RESOLVE | CLASS - 1 | BC-3309.14 FAILURE TO PROTECT WINDOWS AT ADJACENT PROPERTIES. AT TIME OF INSPECTION ON A ACTIVE JOBSITE OF A 4 STORY ... | $625 | $0 | Mar 18, 2019 |
| Dec 13, 2018 | 35380333N | RESOLVE | CLASS - 1 | BC-3309.1 FAILURE TO PROVIDE OVERHEAD PROTECTION. AT TIME OF INSPECTION ON A ACTIVE JOBSITE OF A 4 STORY BUILDING, CU... | $625 | $0 | Mar 18, 2019 |
| Dec 13, 2018 | 35380330H | RESOLVE | CLASS - 2 | NO DESIGNATED COMPETENT PERSON ON SITE. AT TIME OF INSPECTION ON A ACTIVE JOBSITE OF A 4 STORY BUILDING, CURRENTLY AT... | $0 | $0 | Mar 20, 2019 |
| Jul 11, 2018 | 35345207Z | RESOLVE | CLASS - 1 | BC3303.3.FAILURE TO OBTAIN 2 OT PERMIT FOR SANITARY FICILITY AT SIDEWALK.AT TIME OF INSPECTION OF A NEW BUILDING UNDE... | $625 | $0 | Sep 17, 2018 |
| Jul 11, 2018 | 35345204N | RESOLVE | CLASS - 1 | BC3301.2.FAILURE TO INSTITUTE OR MAINTAIN SAFETY EQUIPMENT MEASURES OR TEMPORARY CONSTRUCTION-NO REBAR CAPS.AT TIME O... | $625 | $0 | Sep 17, 2018 |
| Jul 11, 2018 | 35345206R | RESOLVE | CLASS - 1 | BC3303.2.2.FIRE HYDRANT USE WITHOUT THE REQUIRED BACKFLOW PREVENTION DEVICE.AT TIME OF INSPECTION OF NEW BUILDING UND... | $625 | $0 | Sep 17, 2018 |
| Jul 10, 2018 | 35345205P | RESOLVE | CLASS - 1 | BC3304.7.FAILURE TO PROVIDE AT LEAST 1 SAFE MEANS OF EGRESS FROM EXCAVATED AREAS.AT TIME OF INSPECTION OF A NEW 4 STO... | $625 | $0 | Sep 17, 2018 |
| May 8, 2018 | 35331172K | RESOLVE | CLASS - 1 | SEC: BC 3313.1, 3301.1.2. FAILURE TO PROVIDE FDNY PERMIT FOR STORAGE/USAGE OF OXYGEN/ACETYLENE @ JOB SITE. @ TIME OF ... | $625 | $0 | Jul 9, 2018 |
| May 8, 2018 | 35331171Z | RESOLVE | CLASS - 1 | SEC: BC 3301.13.1. FAILURE TO PROVIDE SSP BY LOCAL LAW OF 2017. @ TIME OF INSP OF A NEW 4 STORY NEW BLDG UNDER CONSTR... | $625 | $0 | Jul 9, 2018 |