Maintenance code violations
1040 40 Street, Brooklyn • Block 05587 • Lot 0023
243 records
HPD grades a violation A for non-hazardous through C for immediately hazardous.
| Issued | Class | Status | Violation | Apartment | Correct by |
|---|---|---|---|---|---|
| Nov 14, 2016 | C | NOV SENT OUT | § 27-2005 ADM CODE REPLACE WITH NEW THE MISSING 4 BAULSTERS AT PUBLIC HALL STAIRS, 2nd STORY | — | Nov 22, 2016 |
| Nov 14, 2016 | B | NOV SENT OUT | § 27-2018 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 2, 1st STORY, APA... | 2 | Dec 19, 2016 |
| Nov 14, 2016 | B | NOV SENT OUT | § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 2, 1st STORY, ... | 2 | Dec 19, 2016 |
| Nov 14, 2016 | C | NOV SENT OUT | § 27-2005, 2006, 2037 HMC: PROPERLY REPAIR AND ABATE UNSAFE ELECTRIC WIRING CONDITION CONSISTING OF EXSPOSED ELCTRICA... | 1 | Nov 22, 2016 |
| Nov 14, 2016 | C | NOV SENT OUT | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE ROTTED WOOD FLOOR IN THE KITCHEN LOC... | 1 | Nov 22, 2016 |
| Nov 14, 2016 | C | NOV SENT OUT | § 27-2024 ADM CODE PROVIDE ADEQUATE SUPPLY OF COLD WATER FOR THE FIXTURES THROUGH ENTIRE IN THE BATHROOM LOCATED AT A... | 1 | Nov 22, 2016 |
| Nov 14, 2016 | C | NOV SENT OUT | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR IN THE PRIVATE HALLWAY LO... | 1 | Nov 22, 2016 |
| Nov 14, 2016 | A | NOV SENT OUT | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT ALL WALLS AND CEILINGS IN... | 1 | Feb 17, 2017 |
| Nov 14, 2016 | A | NOV SENT OUT | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT WALLS AND CEILING AT PUBLIC ... | — | Feb 17, 2017 |
| Nov 14, 2016 | C | NOV SENT OUT | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR WALLS AND CEILING T... | 1 | Nov 22, 2016 |
| Nov 14, 2016 | B | NOV SENT OUT | § 27-2005 ADM CODE REPLACE WITH NEW THE MISSING 2 MISSING BAULSTERS AT PUBLIC HALL, 1st STORY | — | Dec 19, 2016 |
| Nov 14, 2016 | A | NOV SENT OUT | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT ALL WALLS AND CEILINGS IN... | 2 | Feb 17, 2017 |
| Nov 14, 2016 | A | NOV SENT OUT | § 300 M/D LAW FILE PLANS AND APPLICATION AND LEGALIZE THE FOLLOWING ALTERATION OR RESTORE TO THE LEGAL CONDITION EXIS... | 3 | Feb 17, 2017 |
| Nov 14, 2016 | A | NOV SENT OUT | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT WALLS AND CEILING AT PUBLIC ... | — | Feb 17, 2017 |
| Nov 14, 2016 | C | NOV SENT OUT | § 27-2005 ADM CODE REPLACE WITH NEW THE MISSING 6 MISSING BAULSTERS AT PUBLIC HALL STAIRS | — | Nov 22, 2016 |
| Nov 14, 2016 | B | NOV SENT OUT | § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING IN THE ENTIRE APARTMENT LOCATED A... | 3 | Dec 19, 2016 |
| Nov 14, 2016 | B | NOV SENT OUT | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE PLASTER AT WALLS AND CEILING AT PUBL... | — | Dec 19, 2016 |
| Nov 14, 2016 | B | NOV SENT OUT | § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING IN THE ENTIRE APARTMENT LOCATED A... | 2 | Dec 19, 2016 |
| Nov 14, 2016 | B | NOV SENT OUT | § 27-2018 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 1, APARTMENT AT S... | 1 | Dec 19, 2016 |
| Nov 14, 2016 | C | NOV SENT OUT | § 27-2026 ADM CODE REPLACE THE BROKEN OR DEFECTIVE WATER CLOSET IN THE BATHROOM LOCATED AT APT 1, APARTMENT AT SOUTH | 1 | Nov 22, 2016 |
| Nov 14, 2016 | C | NOV SENT OUT | § 27-2024 ADM CODE PROVIDE ADEQUATE SUPPLY OF HOT WATER FOR THE FIXTURES THROUGH OUT ENTIRE IN THE BATHROOM LOCATED A... | 1 | Nov 22, 2016 |
| — | I | VIOLATION DISMISSED | §27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE §27... | — | — |
| May 23, 2016 | B | NOV SENT OUT | § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING IN THE ENTIRE APARTMENT LOCATED A... | 3 | Jun 27, 2016 |
| May 23, 2016 | B | NOV SENT OUT | § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 3, 3rd STORY, ... | 3 | Jun 27, 2016 |
| May 23, 2016 | C | VIOLATION CLOSED | § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 3, 3rd STORY, 1... | 3 | May 17, 2016 |
| May 23, 2016 | C | VIOLATION CLOSED | § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 1, 1st STORY, 1... | 1 | May 17, 2016 |
| May 19, 2016 | B | CERTIFICATION POSTPONMENT DENIED | § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING IN THE ENTIRE APARTMENT LOCATED A... | 1 | Jun 23, 2016 |
| May 19, 2016 | B | CERTIFICATION POSTPONMENT DENIED | § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 1, 1st STORY, ... | 1 | Jun 23, 2016 |
| May 19, 2016 | C | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE GYPSUM SOFFIT AT CELLAR STAIRS. AT C... | — | May 27, 2016 |
| May 19, 2016 | C | VIOLATION CLOSED | § 27-2026 ADM CODE REPAIR THE FLUSHING APPARATUS AND MAINTAIN SAME SO AS TO FLUSH EFFECTIVELY THE WATER CLOSET IN THE... | 3 | May 27, 2016 |
| May 19, 2016 | C | VIOLATION CLOSED | § 27-2037, 2038 HMC: PROVIDE A SAFE AND ADEQUATE SUPPLY OF ELECTRIC SERVICE TO THE FIXTURES ALL STORIES AT PUBLIC HALL | — | May 27, 2016 |
| Feb 19, 2016 | B | NOV SENT OUT | § 27-2005 HMC:TRACE AND REPAIR THE SOURCE AND ABATE THE NUISANCE CONSISTING OF MOLD ... AT CEILING IN THE BATHROOM LO... | 3 | Mar 25, 2016 |
| Feb 19, 2016 | C | NOV SENT OUT | § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 3, 2nd STORY, 1... | 3 | Feb 18, 2016 |
| Feb 19, 2016 | C | VIOLATION CLOSED | § 27-2028, 2032 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF HEAT FROM AN APPROVED CENTRAL HEATING SYSTEM, OR AN APPROVED S... | 3 | Feb 18, 2016 |
| Feb 19, 2016 | B | NOV SENT OUT | § 27-2005, 2007 ADM CODE FIRE EGRESS DEFECTIVE. MAKE STATIONARY THE IRON LADDER LEADING TO SCUTTLE OPENING IN ROOF ..... | — | Mar 25, 2016 |
| Dec 14, 2015 | C | VIOLATION DISMISSED | § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 1, 1st STORY, 1... | 1 | Dec 10, 2015 |
| Dec 14, 2015 | C | VIOLATION DISMISSED | § 27-2028, 2032 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF HEAT FROM AN APPROVED CENTRAL HEATING SYSTEM, OR AN APPROVED S... | 1 | Dec 10, 2015 |
| Nov 19, 2015 | C | VIOLATION CLOSED | § 27-2010, 2011, 2012 ADM CODE CLEANSE AND DISINFECT TO THE SATISFACTION OF THIS DEPARTMENT AFTER REMOVING THE WASTE ... | — | Nov 27, 2015 |
| Nov 19, 2015 | B | NOV SENT OUT | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDENT MATERIAL AT CEILING A... | — | Dec 24, 2015 |
| Nov 19, 2015 | C | VIOLATION CLOSED | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING AT CELLAR | — | Nov 27, 2015 |
| Oct 30, 2015 | B | NOV SENT OUT | § 27-2040 ADM CODE PROVIDE ADEQUATE LIGHTING AT OR NEAR THE OUTSIDE OF THE FRONT ENTRANCEWAY OF THE BUILDING AND KEEP... | — | Dec 4, 2015 |
| Oct 30, 2015 | B | NOV SENT OUT | § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF 2 SCREW JACKS AT CELLAR | — | Dec 4, 2015 |
| Oct 26, 2015 | C | VIOLATION DISMISSED | § 27-2005, 2006, 2037 HMC: PROPERLY REPAIR AND ABATE UNSAFE ELECTRIC WIRING CONDITION CONSISTING OF ILLEGAL WIRE TAPP... | — | Nov 3, 2015 |
| Oct 26, 2015 | C | VIOLATION CLOSED | § 27-2005 ADM CODE PROVIDE SEAL AT ENTRANCE DOOR IN THE 1st ROOM FROM EAST AT CENTER LOCATED AT APT, 2nd STORY, 1st A... | — | Nov 3, 2015 |
| Oct 26, 2015 | C | VIOLATION CLOSED | § 27-2005 ADM CODE PROVIDE SEAL FOR ALL ACCESSIBLE OPENINGS AT CELLAR | — | Nov 3, 2015 |
| — | I | VIOLATION DISMISSED | §27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE §27... | — | — |
| Aug 18, 2015 | B | NOV SENT OUT | § 27-2021 ADM CODE PROVIDE SUFFICIENT, PROPER AND SEPARATE METAL RECEPTACLES FOR THE DEPOSIT OF GARBAGE, RUBBISH AND ... | — | Sep 22, 2015 |
| Jul 13, 2015 | B | NOV SENT OUT | § 27-2039 ADM CODE PROVIDE ADEQUATE LIGHT OF NOT LESS THAN 60 WATTS INCANDESCENT OR EQUIVALENT ILLUMINATION .. AT PUB... | — | Aug 17, 2015 |
| Jul 13, 2015 | B | NOV SENT OUT | § 27-2039 ADM CODE PROVIDE ADEQUATE LIGHT OF NOT LESS THAN 60 WATTS INCANDESCENT OR EQUIVALENT ILLUMINATION .. AT PUB... | — | Aug 17, 2015 |
| — | I | VIOLATION DISMISSED | §27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE §27... | — | — |