Issued Violation Status Severity Description Penalty Balance due Hearing
Jun 11, 2026 39192258J ACTIVE CLASS - 1 OCCUPANCY CONTRARY TO THAT ALLOWED BY THE CERTIFICATE OF OCCUPANCY OR BUILDINGS DEPARTMENT RECORDS. CONTRARY TO FINAL... $6,250 $6,250 Aug 26, 2026
May 17, 2024 39114717X ACTIVE CLASS - 1 OCCUPANCY CONTRARY TO THAT ALLOWED BY THE CERTIFICATE OF OCCUPANCY OR BUILDINGS DEPARTMENT RECORDS. : AT 3RD FLOORS O... $2,500 $0 Jul 24, 2024
Apr 18, 2024 39112034H ACTIVE CLASS - 2 OCCUPANCY CONTRARY TO THAT ALLOWED BY THE CO OR BUILDINGS DEPT. RECORDS; DEPT OF BUILDING RECORD CO INDICATE #3138482... $6,250 $6,250 Feb 24, 2025
Nov 13, 2020 35509503L RESOLVE CLASS - 1 SEC. 28-401.4 ILLEGALLY ENGAGING IN ANY BUSINESS OR OCCUPATION W/O A REQUIRED LICENSE OR OTHER AUTHORIZATION. AT THE ... $5,000 $5,000 Apr 28, 2021
Nov 13, 2020 35510396N RESOLVE CLASS - 1 CONSTRUCTION SUPERINTENDNET FAILED TO PERFORM DUTIES PER CODE AT THE TIME OF MY INSPECTION ACTIVE JOB SITE WORKERS PE... $10,000 $10,000 Apr 28, 2021
Nov 13, 2020 35510395L RESOLVE CLASS - 1 WORK DOES NOT CONFORM TO APPROVED CONSTRUCTION DOCUMENTS AND/OR AMENDMENTS AT THE TIME OF INSPECTION I OBSERVED WOR P... $2,500 $2,500 Apr 28, 2021
Nov 13, 2020 35510393H RESOLVE CLASS - 2 TEMPORARY CONSTRUCTION EQUIPMENT ON SITE EXPIRED PERMIT AT THE TIME OF INSPECTION I OSBERVED CONSTRUCTION FENCE INSTA... $625 $625 Apr 28, 2021
Nov 13, 2020 35510394J RESOLVE CLASS - 1 FAILURE TO PROVIDE PRE SHIFT SAFTEY MEETING TO WORKERS PRIOR TO COMMENCMENET OF WORK AT THE TIM EOF MY INSPECTION ACT... $5,000 $5,000 Apr 28, 2021
Dec 9, 2019 35463366N RESOLVE CLASS - 2 CONSTRUCTION SUPERINTENDNET FAILED TO PERFURM DUTIES AS PER RULE AT THE TIME OF MY INSPECTION IT WAS OBSERVED THAT TH... $2,500 $0 Oct 16, 2020
Dec 9, 2019 35463367P RESOLVE CLASS - 2 BC3301.6=DEISGN DRAWINGS REQUIRED BY CHAPTER 33 NOTED DURING MNY INSPECTION IT WAS OBSERVED MAKESHIFT /WOODEN SCAFFOL... $0 $0 Apr 15, 2020
Dec 9, 2019 35463368R RESOLVE CLASS - 1 BC3303.2.7=EXITSING SERVICES NOT MAINTAINED AT THE TIME OF MY INSPECTION IT WAS OBSERVED THAT AT EXPOSURE # ONE CONTR... $2,500 $0 Oct 16, 2020
Dec 9, 2019 35463369Z RESOLVE CLASS - 2 BC113.6.1=REPSONSIBILTY OF WONER OF TELLER BUIDLING NOTED AT EXP #4 ON ACTIVE CONSTRUCTION SITE AT 3RD FLOOR CHIMNEY ... $625 $0 Oct 16, 2020
Sep 13, 2019 35444709M RESOLVE CLASS - 2 PERMIT HOLDER FAIL TO PROVIDE ACCESS ON OR EXPOSURE WOKR ON ACTIVE SITE AS NOTED AT TIME OF MY INSPECTION ON AN ACTIE... $1,250 $1,250 Jan 17, 2020
Sep 11, 2019 35449700Z RESOLVE CLASS - 1 BC33053612-RESHORES IN PROXIMITY TO ENCLOSED PERIMETERS.AT TIME OF INSPECTION ON A 7 STORY BUILDING OBSERVED #3,#4,#5... $2,500 $2,500 Jan 15, 2020
Sep 4, 2019 35438854H RESOLVE CLASS - 1 HOUSEKEEPING NOTE:@TIME OF MY INSPECTION OF A NEW 7 BUILDING UNDER CONSTRUCTION @6STY STAGE ACTIVE, JOBSITE. I OBSERV... $2,500 $2,500 Jan 8, 2020
Sep 4, 2019 35438855J RESOLVE CLASS - 1 3308.5 FAILURE TO MAINTAIN VERTICAL SAFETY NETTING SYSTEM AS REQUIRED.NOTE: @THE TIME OF MY INSPECTION OF A 7 STY @6S... $625 $625 Jan 10, 2020
Aug 20, 2019 35445459N RESOLVE CLASS - 1 BC 3309.10 INADEQUATE ROOF PROTECTION AT TIME OF INSPECTION IN RESPONSE TO COMPLAINT#3718791,OBSERVED FROM STREET LEV... $2,500 $2,500 Dec 30, 2019
May 23, 2019 35418465X RESOLVE CLASS - 1 2113.1.6;FAILURE TO PROTETC OR ADEQUATELY PROTETC ADJOINING PROPERTY DURING CONSTRUCTION OPERATION NO CHIMNEY PROTECT... $2,500 $2,500 Sep 18, 2019
May 23, 2019 35418460R RESOLVE CLASS - 1 FAILURE TO SAFEGUARD ALL PERSONS AND PROPERTY AFFECTED BY CONSTRUCTION OPERATION NO OVER PROTECTION NOTE:AT TIME OF I... $10,000 $10,000 Sep 9, 2019
May 23, 2019 35418461Z RESOLVE CLASS - 1 SEC. 3309.10 FAILURE TO PROVIDE ADEQUATE ROOF PROTECTION FOR ADJOININGPROPERTIES/MISSING ROOIF PROTECTION AT EXP#2&4.... $2,500 $2,500 Sep 9, 2019
May 23, 2019 35418469N RESOLVE CLASS - 2 FAILURE TO POST NO SMOKING SIGNS AT CONSTRUCTION SITE AS PER FIRE CODE.NOTE:AT TIME OF INSPECTION OF A 7 STORY NEW BU... $0 $0 Sep 16, 2019
May 23, 2019 35418470K RESOLVE CLASS - 2 3309.11:FAILURE TO PROTECT OR ADEQUATELY PROTECT ADJONING TREES DURING CONSTRUCTION OPERATIONS NOTE:AT TIME OF INSPEC... $0 $0 Sep 16, 2019
May 23, 2019 35418464Y RESOLVE CLASS - 1 FAILURE TO INSTITUTE/MAINTAIN SAFETY EQUIPMENT MEASURES OR TEMPORARY CONSTRUCTION NO GUARD RAILS.NOTE;AT TIME OF INSP... $2,500 $2,500 Sep 16, 2019
May 23, 2019 35418463M RESOLVE CLASS - 1 FAILURE O INSTITUTE/MAINTAIN SAFETY EQUIPEMENT MEASURES OR TEMPORARY CONSTRUCTION NO TOE BOARDS NOTE:AT TIME OF INSPE... $5,000 $5,000 Sep 18, 2019
May 23, 2019 35418468L RESOLVE CLASS - 1 3303.7.2;NO FIRE EXTINGUISHERS NOTE:AT TIME OF INSPECITON OF A 7 STORY NEW BUILDING UNDER CONSTRUCTION AT 6TH FLOOR L... $2,500 $2,500 Sep 18, 2019
May 23, 2019 35418471M RESOLVE CLASS - 1 3307.2.6;REQUIREMENTS FOR SIDEWALK NOT MIANTAINED NOTE:AT TIME OF INSPECTION RESTORING TO A COMPLAINT I OBSERVED THAT... $2,500 $2,500 Sep 18, 2019
May 23, 2019 35418466H RESOLVE CLASS - 1 28-103.8;CONCRETE SAFETY EMBEDET STRAPS NO MAINTEANANCE LOGS MATTERS NOT PROVIDED FOR EMBEDED SAFETY STAIRS.NOTE AT T... $2,500 $2,500 Sep 18, 2019
May 23, 2019 35418467J RESOLVE CLASS - 1 FAILURE TO MAINTAIN ADEQUATE HOUSEKEEPING PER SECTION REQUIREMENTS.NOTELAT TIME OF INSPECTION OF A 7 STORY N.B. UNDER... $2,500 $2,500 Sep 18, 2019
Feb 19, 2019 35377255J RESOLVE CLASS - 1 FAILURE TO SAFEGUARD ALL PERSONS & PROPERTY AFFECTED BY CONSTRUCTION OPERATIONS. AT TIME OF INSPECTION I OBSERVED A A... $10,000 $0 Jun 12, 2019
Feb 19, 2019 35369126N RESOLVE CLASS - 2 BC 3301.7 FAILURE TO PROVIDE PE APPROVED DESIGN DRAWINGS. AS NOTED AT TIME OF INSPECTION,ACTIVE SITE FAILURE TO PROVI... $0 $0 Jun 3, 2019
Feb 19, 2019 35377254H RESOLVE CLASS - 1 FAILURE TO SAFEGUARD ALL PERSONS & PROPERTY AFFECTED BY CONSTRUCTION OPERATIONS. AT TIME OF INSPECTION I OBSERVED A A... $0 $0 Jun 12, 2019
Feb 19, 2019 35377256L RESOLVE CLASS - 2 CONSTRUCTION SUPERINTENDENT FAILED TO PERFORM DUTIES PER CODE. AT TIMEOF INSPECTION I OBSERVED ACTIVE 7 STY JOB SITE ... $5,000 $0 Jun 3, 2019
Feb 18, 2019 35375193Y RESOLVE CLASS - 1 FAILURE TO SAFEGUARD ALL PERSONS AND PROPERTY AFFECTED BY CONSTRUCTIONOPERATIONS. NOTED ON ACTIVE JOBSITE,AT EXPOSURE... $10,000 $0 Jun 12, 2019
Aug 14, 2018 35333799N RESOLVE CLASS - 2 FAILURE TO PROVIDE APPROVED/ACCEPTED PLANS AT JOB SITE AT TIME OF INSPECTION. NOTED: THE PLANS(DRAWINGS ON SITE)DO NO... $530 $0 Jun 5, 2019
Apr 1, 2017 35247116Y RESOLVE CLASS - 1 SEC. 3307.7 & 27-1021 FAILURE TO PROVIDE ADEQUATE CONSTRUCTION FENCE. AT THE TIME OF INSPECTION IT WAS OBSERVED THAT ... $800 $0 May 22, 2017
Apr 1, 2017 35247118H RESOLVE CLASS - 2 FAILURE TO SAFEGUARD ALL PERSONS & PROPERTY AFFECTED BY CONSTRUCTION OPERATIONS. AT THE TIME OF INSPECTION IT WAS OBS... $5,000 $0 Jun 1, 2017
Apr 1, 2017 35247117X RESOLVE CLASS - 1 FAILURE TO NOTIFY DOB W/I 24-48HRS OF THE START OF EXCAVATION. AT THE TIME OF INSPECTION IT WAS OBSERVED THAT EXCAVAT... $1,200 $0 Jun 1, 2017