Skip to content

Maintenance code violations

1974 84 Street, Brooklyn • Block 06333 • Lot 0037

74 records

HPD grades a violation A for non-hazardous through C for immediately hazardous.

Issued Class Status Violation Apartment Correct by
May 28, 2008 A VIOLATION CLOSED D26-12.01 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT WALLS AND CLG EAST ROOM 2ND ... Aug 31, 2008
May 28, 2008 B VIOLATION CLOSED D26-10.01 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF STAIR TREADS OUT OF STRINGER 3 STY PUB HALL TO ROOF. Jul 2, 2008
May 28, 2008 B VIOLATION CLOSED D26-10.01 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE 4 INCH CAST IRON VENT PIPE ROOF CENTER. Jul 2, 2008
May 28, 2008 B VIOLATION CLOSED D26-19.05 ADM CODE PROVIDE ADEQUATE LIGHT OF NOT LESS THAN 60 WATTS INCANDESCENT OR EQUIVALENT ILLUMINATION ALL STYS ... Jul 2, 2008
May 28, 2008 B VIOLATION CLOSED D26-19.05 ADM CODE PROVIDE ADEQUATE LIGHT OF NOT LESS THAN 60 WATTS INCANDESCENT OR EQUIVALENT ILLUMINATION VESTIBULE... Jul 2, 2008
Jul 28, 2006 A VIOLATION CLOSED SECTION 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT WALLS THROUGH OUT AT P... Nov 24, 2006
Jul 28, 2006 A VIOLATION CLOSED SECTION 27-2048 ADM CODE PAINT OR POST A SIGN INDICATING FLOORS ON WALL THROUGH OUT AT PUBLIC HALL STAIRS BLDG Nov 24, 2006
Jul 28, 2006 A VIOLATION CLOSED SECTION 62 M/D LAW REARRANGE TELEVISION AND/OR RADIO ANTENNA TO BE AT LEAST 10 FEET ABOVE ROOF AND NOT ATTACHED TO AN... Nov 24, 2006
Jul 28, 2006 A VIOLATION CLOSED SECTION 27-2045 ADM CODE POST A PROPER NOTICE OF SMOKE DETECTOR REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER,... Nov 24, 2006
Jul 28, 2006 A VIOLATION CLOSED SECTION 53, 187, 231 M/D LAW AND DEPARTMENT RULES AND REGULATIONS. PROVIDE A SHOE PROPERLY SECURED TO BOTTOM OF STRIN... Nov 24, 2006
Mar 26, 2004 B VIOLATION CLOSED SECTION 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF EXPOSED ELECTRICAL WIRES CEILING AT NORTH 2 A... 3 May 5, 2004
Mar 26, 2004 B VIOLATION CLOSED SECTION 27-2005 ADM CODE REPLACE WITH NEW THE MISSING ELECTRICAL COVERPLATE TO ELECTRICAL SWITCHES AND OUTLETS IN THE... 3 May 5, 2004
Mar 26, 2004 B VIOLATION CLOSED SECTION 27-2005 ADM CODE PROPERLY SECURE THE LOOSE WASHBASIN IN THE 1st BATHROOM FROM EAST LOCATED AT APARTMENT 3, 3r... 3 May 5, 2004
Mar 26, 2004 B VIOLATION CLOSED SECTION 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF MILDEW AROUND BATHTUB IN THE BATHROOM LOCATED... 3 May 5, 2004
Mar 26, 2004 B VIOLATION CLOSED SECTION 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF ENTRANCE DOOR PAINTED SHUT IN THE 3rd ROOM FR... 3 May 5, 2004
Mar 26, 2004 C VIOLATION CLOSED SECTION 27-2005 ADM CODE REPLACE WITH NEW THE MISSING RADIATOR IN THE 2nd ROOM FROM NORTH LOCATED AT APT 3, 3rd STORY... 3 Apr 6, 2004
Mar 26, 2004 B VIOLATION CLOSED SECTION 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 3, 3rd S... 3 May 5, 2004
Mar 26, 2004 B VIOLATION CLOSED SECTION 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR NEAR RADIATOR IN TH... 3 May 5, 2004
Mar 26, 2004 B VIOLATION CLOSED SECTION 27-2005 ADM CODE REPLACE WITH NEW THE MISSING LIGHT FIXTURE CEILING NORTH 2 AND IN THE 1st ROOM FROM NORTH LO... 3 May 5, 2004
Aug 2, 2002 B VIOLATION CLOSED SECTION 27-2005 ADM CODE PROPERLY SECURE THE LOOSE 14TH WOOD TREAD UP FROM BOTTOM AT PUBLIC HALL STAIRS, 3rd STORY Sep 11, 2002
Aug 2, 2002 C VIOLATION CLOSED SECTION 27-2005, 2007 ADM CODE REMOVE THE ILLEGAL FASTENING DOUBLE CYLINDER KEY OPERATED LOCK INSTALLED AT DOOR AT FR... Aug 13, 2002
Aug 2, 2002 B VIOLATION CLOSED SECTION 27-2005 ADM CODE REPLACE WITH NEW THE MISSING GLASS AT DOUBLE DOORS AT VESTIBULE AT PUBLIC HALL, 1st STORY Sep 11, 2002
Aug 2, 2002 B VIOLATION CLOSED SECTION 27-2005, 2007 ADM CODE REMOVE ALL ENCUMBRANCES CONSISTING OF BICYCLES AND SHOES AT PUBLIC HALL STAIRS, 3rd STORY Sep 11, 2002
Aug 2, 2002 B NOT COMPLIED WITH SECTION 27-2005, 2007 ADM CODE REMOVE ALL ENCUMBRANCES CONSISTING OF WIRES CREATING TRIP HAZARD , ROOF Sep 11, 2002