| Dec 23, 2025 | 39171435Z | RESOLVE | CLASS - 1 | CEASE USE ITEM DEFECTIVE/DISABLED DISC BRAKE MONITOR. CLASS 2 ITEMS: CLEAN TAIL ROPE FOR PROPER INSPECTION. SEAL HOIS... | $1,250 | $0 | Mar 4, 2026 |
| Nov 21, 2024 | 39130988H | RESOLVE | CLASS - 2 | INOPERATIVE PHONE. SEAL HOSIT AMCHINE LEAKS. MAINTNENANCE LOG MISSING. | $0 | $0 | Feb 5, 2025 |
| Apr 2, 2024 | 39110571Y | RESOLVE | CLASS - 1 | ONLY ELEVATOR IN A BUILDING SECTION OUT OF SERVICE. THIS CONDITION AFFECTS NUMEROUS TENANTS, INCLUDING THOSE WITH SPE... | $3,125 | $0 | Jun 12, 2024 |
| Jul 12, 2023 | 39090085N | RESOLVE | CLASS - 1 | FAILURE TO SAFEGUARD. OBSERVED AT EXP#1 BUILDING S LINE FIRE ESCAPE EXIT PASSAGEWAY TO STREET OBSTRUCTED BY CONSTRUCT... | $2,500 | $0 | Mar 19, 2024 |
| Jul 10, 2023 | 39089970H | ACTIVE | CLASS - 2 | OBSERVED IN BOTH LAUNDRY ROOMS LOCATED ON THE GROUND FLOOR RESIDENTIAL GAS FLEXES ON ALL 4 OF THE COMMERCIAL DRYERS. ... | $625 | $0 | Oct 16, 2023 |
| Jul 10, 2023 | 39089971J | RESOLVE | CLASS - 2 | I OBSERVED ON GROUND FLOOR IN THE GAS/ ELECTRICAL METER ROOMS EXCESSIVE AMOUNTS OF COMBUSTIBLE STORAGE( 2 REFRIGERATO... | $625 | $0 | Oct 16, 2023 |
| May 23, 2023 | 39086950R | RESOLVE | CLASS - 1 | CLASS 1: CEASE USE ITEMS. REPLACE DAMAGED HOISTWAY ROPES., REGROVE TRACTIONS SHEAVE. *** FILE APPLICATIONS AND OBTAIN... | $1,250 | $0 | Aug 2, 2023 |
| May 23, 2023 | 39086949J | RESOLVE | CLASS - 2 | CLEAN HOIST MACHINE., SEAL HOIST MACHINE., REPAIR MOTOR ROOM LIGHTS. | $0 | $0 | Aug 2, 2023 |
| Oct 21, 2022 | 39072440J | RESOLVE | CLASS - 1 | CLASS ONE ITEM: INOPERATIVE DISC BRAKE MONITOR; PARAMETER SET TO ZERO IN CONTROLLER. CLASS 2 ITEMS: ROUGE DEVELOPING ... | $1,250 | $0 | Mar 22, 2023 |
| Oct 21, 2022 | 39072439M | RESOLVE | CLASS - 1 | CLASS ONE ITEM: INOPERATIVE DISC BRAKE MONITOR; PARAMETER SET TO ZERO IN CONTROLLER. CLASS 2 ITEMS: ROUGE DEVELOPING ... | $1,250 | $0 | Apr 26, 2023 |
| Mar 14, 2022 | 35645102R | RESOLVE | CLASS - 2 | TEMPORARY CONSTRUCTION EQUIPMENT ON SITE W/AN EXPIRED PERMIT(CONSTRUCTION FENCE EXPIRED PERMIT).NOTE:AT THE TIME OF M... | $620 | $0 | Aug 3, 2022 |
| Mar 14, 2022 | 35645101P | RESOLVE | CLASS - 1 | WORK DOES NOT CONFORM TO APPROVED CONSTRUCTION DOCUMENTS.STOP ALL WORKFOR MAIN ENTRANCE TO 1000 OCEAN PARKWAY,AREA NO... | $2,500 | $0 | Aug 3, 2022 |
| Aug 24, 2021 | 35581409L | RESOLVE | CLASS - 1 | FAILURE TO PROVIDE UNOBSTRUCTED EXIT PASSAGEWAY AS NOTED.AT TIME OF INSPECTION OBSERVED AT EXP1 A CONSTRUCTION FENCE ... | $312 | $0 | Jan 5, 2022 |
| Mar 24, 2021 | 35548934P | RESOLVE | CLASS - 1 | SEC. 3301.7 FAILURE TO PROVIDE PE APPROVED DESIGN DRAWINGS FOR SHORINGOF CANOPY. AT TIME OF INSPECTION OF AN ACTIVE P... | $0 | $0 | Aug 11, 2022 |
| Mar 24, 2021 | 35548935R | RESOLVE | CLASS - 1 | WORK DOES NOT CONFORM TO APPROVED CONSTRUCTION DOCUMENTS AT TIME OF INSPECTION OBSERVED SHORING SUPPORTING A CANOPY L... | $0 | $0 | Aug 11, 2022 |
| Mar 24, 2021 | 35548933N | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN EXTERIOR BLDG FACADE & APPURTENANCES. AT TIME OF INSPECTION OBSERVED DILAPIDATED ARCH TYPE STRUCT... | $0 | $0 | Feb 10, 2022 |
| Dec 29, 2020 | 35549505L | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN EXTERIOR BUILDING FACADE AND APPURTENANCES AS NOTED BUILDING STILL HAVE CONDITION FROM SUMMONS 35... | $6,250 | $0 | Jun 9, 2021 |
| Sep 25, 2020 | 35538995J | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN EXTERIOR BUILDING FACADE AND APPURTENANCES. AS NOTED EXPOSURE 1:DAMAGED ARCH STRUCTURE AT FRONT E... | $2,500 | $0 | Mar 3, 2021 |
| Mar 19, 2020 | 39020027L | RESOLVE | CLASS - 1 | WORK WITHOUT A PERMIT. AT TIME OF INSPECTION OBSERVED STRUCTURAL STEEL SHORING INSTALLED CONSISTING OF 4 TEMPORARY ST... | $0 | $0 | Jul 22, 2020 |
| Mar 19, 2020 | 39020026J | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN BUILDING. AT TIME OF INSP. OBSERVED MASONRY ARCHWAY IN DISREPAIR WHERE STRUCTURAL STEEL MEMBERS H... | $0 | $0 | Jul 22, 2020 |
| Oct 15, 2018 | 37013099M | RESOLVE | CLASS - 2 | FAILURE TO SUBMIT A RQUIRED CYCLE 8B REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WALL AND APPURT... | $0 | $0 | Feb 24, 2020 |
| Aug 29, 2018 | 39000269X | RESOLVE | CLASS - 2 | ADJUST SPRING CLOSURES WHERE NEEDED, REPAIR CAR LIGHTING, REPLACE HOISTWAY DOOR GIBS WHERE NEEDED, REPAIR MR SMOKE DE... | $0 | $0 | Oct 15, 2018 |
| Aug 29, 2018 | 39000270N | RESOLVE | CLASS - 2 | RELACE HOISTWAY DOOR GIBS WHERE NEEDED, REPAIR MACHINE ROOM LIGHTING, MR SMOKE DETECTOR INOPERATIVE, ESTABLISH PEST C... | $0 | $0 | Oct 15, 2018 |
| Nov 29, 2017 | 38259770X | RESOLVE | CLASS - 1 | 92X10;59L11;100M7;17H11;16J01;66E11;8M07;67X10:CEASE USE ITEMS;DOOR POSITIONING MONITOR;DISC BRAKE MONITOR DAMAGED;IN... | $1,000 | $0 | Apr 16, 2018 |
| Jan 13, 2012 | 32071629Y | RESOLVE | CLASS - 2 | 15 16 50 50AB 50-MISSING BOILER COVERING 50A-STORAGE IN BOILER ROOM 60B-MISSING LADDER ON BOILER | $0 | $0 | Mar 12, 2012 |
| Jan 4, 2012 | 38220035L | RESOLVE | CLASS - 1 | 59X10,70O02,15L11: CEASE USE ITEM 59X;INOPERATIVE/MISALIGNED BRAKE MONITOR. 15;SCREWS STRIP. | $1,000 | $0 | Feb 27, 2012 |
| Mar 22, 2011 | 34903979X | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER.@ 6TH FLR RIGHTSIDE ENTRANCE BALCONY SUPPORTS TO ROOF OF BALCONY RO... | $0 | $0 | May 9, 2011 |
| Aug 26, 2010 | 38212655M | RESOLVE | CLASS - 2 | 57Q10 61D06 56Y10 56O02 40O02 68B#. 68B-NOT USED. | $500 | $0 | Oct 18, 2010 |
| Aug 26, 2010 | 38212654K | RESOLVE | CLASS - 1 | 16B01 35Q03 41B10 40O02 61D06 61R09 52Q06 45O02 68B# CU21L10. 16B-MAKE ALL SELF CLOSING FROM FULLY OPEN. 35Q-MAIN MOT... | $1,000 | $0 | Oct 22, 2010 |
| Mar 15, 2010 | 38207008J | RESOLVE | CLASS - 3 | 97X10.97 REPAIR AND RESTORE ELEVATOR TO SERVICES SO THAT A FULL INSPECTION CAN BE MADE BY THIS SEPT | $0 | $0 | May 10, 2010 |
| Sep 15, 2008 | 38191234Y | RESOLVE | CLASS - 2 | 08V01.14J10.17H11.56Y10.41D06.41T07.08V01.ADJUST FLSTOPS 1' TO 2' OFF LEVEL 14J10 REPAIR ALIGNMENT OF CORNER MIRROR 1... | $0 | $0 | Nov 3, 2008 |
| Sep 15, 2008 | 38191235X | RESOLVE | CLASS - 2 | 08V01.17H11.42A09.14M07.08V01 ADJUST FL STOPS OFF LEVEL 1' TO 2' 17H11 REPLACE ALL WORN HOISTWAY DOOR GIB 3,5,1 AS NE... | $0 | $0 | Nov 3, 2008 |
| Feb 14, 2008 | 34635509N | RESOLVE | Non-Hazardous | DIRECT TO USE OF SCAFFOLD WITH SUPERVISION USE OF RIGGING EQUIPMENT W/O A SPECIAL RIGGERS LICENSE | $1,250 | $0 | Jun 5, 2008 |
| Jun 26, 2007 | 38167170Y | RESOLVE | Non-Hazardous | 03D06,31H10,38L10,38P16,39P16,08A01,66O02,71Q03,67O02,68O02,33O02,16O02,16T02,83O02,84I10.03-PROPERLY SECURE HANDRAIL... | $0 | $0 | Aug 20, 2007 |
| Aug 18, 2004 | 38148423J | RESOLVE | Non-Hazardous | 85BB05.85BB-PERFORM 5 YEAR TEST TAG. | $0 | $0 | Sep 27, 2004 |
| Feb 4, 2004 | 38144784R | RESOLVE | Non-Hazardous | II17H11/ II08V01/ II85BB05/ 86BB05/ II43H08/ 39I10/ (17H) REPLACE HOISTWAY DOOR GIBS L, 2,3,4,5 FLS (08) ADJUST FLOOR... | $880 | $0 | May 17, 2004 |
| Feb 4, 2004 | 38144783P | RESOLVE | Non-Hazardous | II08V01/ II10H11/ II17H11/ II85BB05/ 86BB05/ 66O02/ (08) ADJUST FLOOR STOP (10) REPLACE CAR DOOR GIBS (17) REPLACE HO... | $880 | $0 | May 17, 2004 |
| Apr 1, 2003 | 38136072Z | RESOLVE | Non-Hazardous | 08V01,10H12,17H12,81U05. (08)ADJUST FLOOR STOP (10)REPLACE CAR DOOR GIBS (17)REPLACE HOISTING DOOR GIBS(ALL FLRS) (81... | $350 | $0 | May 19, 2003 |
| Apr 1, 2003 | 38136073K | RESOLVE | Non-Hazardous | 10H12,17H12,08V01,81U05,38I11,41H08.(10)REPLACE CAR DOOR GIBS (17)REPLACE-HOISTWAY DOOR GIBS (08)ADJUST FLOOR STOP (8... | $350 | $0 | May 19, 2003 |
| Apr 12, 2002 | 32033794K | RESOLVE | Non-Hazardous | 49, 34. PEEP HOLE GLASS MISSING IN THE BACK OF BOILER INSTALL CHECK VALVE (BACK FLOW PREVENTOR) | $180 | $0 | Jul 29, 2002 |
| Mar 19, 2002 | 34319511H | RESOLVE | Non-Hazardous | INSTELLATION OF MECHANICAL EQUIPMENT W/O FIRST OBTIANING AN EQUIPMENT USE PERMIT AND EQIPTMENT WORK PERMIT. (1) CARRI... | $0 | $0 | May 20, 2002 |
| Mar 18, 2002 | 38121550M | RESOLVE | Non-Hazardous | 57O02/ 74O02/ 58O02/ 59O02/ 25Q06/ 31Q06/ 31M07/ 74O CLEAN TOP OF CAR 25Q COVER DOOR OPER. 31Q OPEN WIRING TOP OF CAR... | $180 | $0 | May 6, 2002 |
| Mar 18, 2002 | 38122376K | RESOLVE | Non-Hazardous | 52D6/ 61E11/ 74Y2/ 57O02/ 50Y14/ 58O02/ 59O02/ 35R09/ 52D WIRES AT BRAKE WIRE NOT NEEDED 61E CAMERA CAKE RUBBING ON S... | $440 | $0 | Oct 28, 2002 |
| May 24, 2001 | 38115715K | RESOLVE | Non-Hazardous | 52E1,51E1,52D6,61E11,74Y2,62Y2,62#7,53#7,57O2.51E1 GEAR AND WORM ADJUST 52E1 BROKEN NOT LIFTING ADJUST 52D6 WIRE AT B... | $180 | $0 | Jul 9, 2001 |