Maintenance code violations
1086-1096 East 14 Street, Brooklyn • Block 06715 • Lot 0042
1,330 records
HPD grades a violation A for non-hazardous through C for immediately hazardous.
| Issued | Class | Status | Violation | Apartment | Correct by |
|---|---|---|---|---|---|
| Sep 26, 2019 | B | VIOLATION CLOSED | § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 4J, 4th STORY,... | 4J | Oct 31, 2019 |
| Sep 26, 2019 | C | VIOLATION CLOSED | § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE WINDOW BALANCE AT UPPER SASH IN THE 4th ROOM FROM NORTH A... | 2B | Oct 4, 2019 |
| Sep 26, 2019 | C | VIOLATION CLOSED | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 4G, 4th ... | 4G | Oct 17, 2019 |
| Sep 26, 2019 | C | VIOLATION CLOSED | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 1C, 1st ... | 1C | Oct 17, 2019 |
| Sep 26, 2019 | B | VIOLATION CLOSED | § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING IN THE ENTIRE APARTMENT LOCATED A... | 1G | Oct 31, 2019 |
| Sep 26, 2019 | C | VIOLATION CLOSED | § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE VANITY CABINET IN THE BATHROOM LOCATED AT APT 2B, 2nd STO... | 2B | Oct 4, 2019 |
| Sep 26, 2019 | B | VIOLATION CLOSED | § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE DOORS THROUGH OUT IN THE ENTIRE APARTMENT LOCATED AT APT ... | 2B | Oct 31, 2019 |
| Sep 24, 2019 | C | VIOLATION DISMISSED | § 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) IN ACCORDANCE WITH THE SPECIFICAT... | 4E | Oct 22, 2019 |
| Sep 24, 2019 | A | VIOLATION DISMISSED | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT CEILING IN THE BATHROOM LOCAT... | 4E | Dec 28, 2019 |
| Sep 24, 2019 | B | VIOLATION CLOSED | § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK AT CEILING IN THE BATHROOM LOCATED AT APT 4E, 4th STORY, ... | 4E | Oct 29, 2019 |
| Sep 24, 2019 | B | VIOLATION DISMISSED | § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING IN THE ENTIRE APARTMENT LOCATED A... | 4E | Oct 29, 2019 |
| Sep 24, 2019 | C | VIOLATION CLOSED | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 4E, 4th ... | 4E | Oct 15, 2019 |
| Sep 24, 2019 | C | VIOLATION CLOSED | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 4E, 4th STO... | 4E | Oct 15, 2019 |
| Sep 24, 2019 | B | VIOLATION DISMISSED | § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 4E, 4th STORY,... | 4E | Oct 29, 2019 |
| Sep 23, 2019 | C | VIOLATION CLOSED | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... APPROX 16 SQ FT IN THE BATHROOM ... | 1E | Oct 14, 2019 |
| Sep 23, 2019 | C | VIOLATION DISMISSED | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 2F, 2nd ... | 2F | Oct 14, 2019 |
| Sep 23, 2019 | C | VIOLATION CLOSED | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 2F, 2nd STO... | 2F | Oct 14, 2019 |
| Sep 23, 2019 | C | VIOLATION CLOSED | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... APPROX 10 SQ FT IN THE BATHROOM ... | 1E | Oct 14, 2019 |
| Sep 23, 2019 | C | VIOLATION CLOSED | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE BATHROOM LOC... | 1E | Oct 1, 2019 |
| Sep 23, 2019 | C | VIOLATION CLOSED | § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE WASH BASIN CABINET AT SOUTH WALL IN THE BATHROOM LOCATED ... | 1E | Oct 1, 2019 |
| Sep 23, 2019 | C | VIOLATION CLOSED | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT NORTH WALL IN THE 1st ROOM ... | 3E | Oct 1, 2019 |
| Sep 23, 2019 | B | VIOLATION CLOSED | § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE BASE CABINET AT EAST WALL IN THE KITCHEN LOCATED AT APT 1... | 1E | Oct 28, 2019 |
| Sep 23, 2019 | C | VIOLATION CLOSED | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK NORTH WALL IN THE BATHROOM LOC... | 2F | Oct 1, 2019 |
| Sep 23, 2019 | C | VIOLATION CLOSED | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE BATHROOM LOC... | 3E | Oct 1, 2019 |
| Sep 23, 2019 | A | VIOLATION CLOSED | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT CEILING IN THE BATHROOM LOCAT... | 3E | Dec 27, 2019 |
| Sep 23, 2019 | C | VIOLATION CLOSED | § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE SINK CABINET AT EAST WALL IN THE KITCHEN LOCATED AT APT 3... | 3E | Oct 1, 2019 |
| Sep 19, 2019 | B | VIOLATION DISMISSED | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE BATHROOM LOC... | 1E | Oct 24, 2019 |
| Sep 19, 2019 | C | VIOLATION CLOSED | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... APPROX 30 SQ FT SOUTH WALL IN TH... | 1E | Oct 10, 2019 |
| Sep 19, 2019 | B | VIOLATION DISMISSED | § 27-2005, 2007 ADM CODE FIRE EGRESS DEFECTIVE. REMOVE OBSTRUCTING BARS OR UNLAWFUL GATES FROM AT LEAST 1 WINDOW OR P... | 1E | Oct 24, 2019 |
| Sep 19, 2019 | C | VIOLATION CLOSED | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... APPROX 30 SFQ FT CEILING IN THE ... | 1E | Oct 10, 2019 |
| Sep 19, 2019 | B | VIOLATION DISMISSED | § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE NORTH PANEL OF FLOOR CABINET AT EAST WALL IN THE KITCHEN L... | 1E | Oct 24, 2019 |
| Sep 19, 2019 | C | VIOLATION CLOSED | § 27-2005, 2007 ADM CODE ARRANGE AND MAKE SELF-CLOSING THE DOORS , IN THE ENTRANCE LOCATED AT APT 1E, 1st STORY, 1st ... | 1E | Oct 10, 2019 |
| Sep 19, 2019 | A | VIOLATION DISMISSED | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT ALL PEELING PAINT SURFACES I... | 1E | Dec 23, 2019 |
| Sep 19, 2019 | B | VIOLATION DISMISSED | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR IN THE FOYER LOCATED AT A... | 1E | Oct 24, 2019 |
| Sep 19, 2019 | C | VIOLATION DISMISSED | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 1E, 1st ... | 1E | Oct 10, 2019 |
| Sep 19, 2019 | B | VIOLATION DISMISSED | § 27-2026 ADM CODE REMOVE ALL OBSTRUCTIONS AND REPAIR ALL DEFECTS IN WASTE PIPE AT WASH BASIN IN THE BATHROOM LOCATED... | 1E | Oct 24, 2019 |
| Sep 19, 2019 | B | VIOLATION DISMISSED | § 27-2005 ADM CODE PROPERLY SECURE THE LOOSE WASH BASIN AND CABINET AT SOUTH WALL IN THE BATHROOM LOCATED AT APT 1E, ... | 1E | Oct 24, 2019 |
| Sep 13, 2019 | B | VIOLATION DISMISSED | § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). DEFECTIVE LOCATED AT APT 2E, 2nd STORY, 1... | 2E | Oct 18, 2019 |
| Sep 13, 2019 | B | VIOLATION DISMISSED | § 27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES... | — | Oct 18, 2019 |
| Sep 13, 2019 | A | VIOLATION DISMISSED | § 27-2005 ADM CODE REFIT VESTIBULE DOOR AT PUBLIC HALL, 1st STORY | — | Dec 17, 2019 |
| Sep 13, 2019 | B | VIOLATION DISMISSED | § 27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES... | — | Oct 18, 2019 |
| Sep 13, 2019 | A | VIOLATION DISMISSED | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC FLOOR TILES IN THE BATHROOM ... | 2E | Dec 17, 2019 |
| Sep 13, 2019 | A | VIOLATION DISMISSED | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC TILES AT SOUTH WALL IN THE B... | 2E | Dec 17, 2019 |
| Sep 13, 2019 | A | VIOLATION DISMISSED | § 27-2026 ADM CODE RESET, SO AS TO SECURE A PROPER AND TIGHT CONNECTION, THE WATER CLOSET BOWL ... IN THE BATHROOM LO... | 2E | Dec 17, 2019 |
| Sep 13, 2019 | A | VIOLATION DISMISSED | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOODEN BASE CABINET AT EAST WALL IN ... | 2E | Dec 17, 2019 |
| Sep 13, 2019 | A | VIOLATION DISMISSED | § 27-2005 ADM CODE REPLACE WITH NEW THE MISSING ESCUTCHEON PLATE AT HEAT RISER IN THE BATHROOM LOCATED AT APT 2E, 2nd... | 2E | Dec 17, 2019 |
| Sep 13, 2019 | B | VIOLATION DISMISSED | § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEFECTIVE LOCATED AT APT 2E, 2nd STORY, 1st APARTMENT FROM SO... | 2E | Oct 18, 2019 |
| Sep 13, 2019 | A | VIOLATION DISMISSED | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE PROCELAIN ENAMEL GLAZE AT BATHTUB IN... | 2E | Dec 17, 2019 |
| Sep 13, 2019 | A | VIOLATION DISMISSED | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CAULKING AROUND BATHTUB IN THE BATHR... | 2E | Dec 17, 2019 |
| Sep 11, 2019 | A | VIOLATION DISMISSED | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT ALL PEELING PAINT SURFACES I... | 4E | Dec 15, 2019 |