ECB violations
2586-2596 Stillwell Avenue, Brooklyn • Block 06954 • Lot 0048
29 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Jan 29, 2026 | 39175364Z | RESOLVE | CLASS - 1 | OBSERVED IN THE BASEMENT AND ROOF STAIRCASE A AND B INSTALLED CONCEALED SPRINKLER HEADS INSTALLED IN LIEU OF A REQUIR... | $2,500 | $0 | Jul 1, 2026 |
| May 22, 2025 | 39148789K | RESOLVE | CLASS - 1 | THE ONLY ELEVATOR IN SECTION OF BUILDING OR BUILDING IS OUT-OF-SERVICE. UPON INSPECTION THE DEVICE IS FOUND TO BE OUT... | $1,250 | $0 | Aug 6, 2025 |
| Oct 9, 2024 | 39127077J | RESOLVE | CLASS - 2 | OBSERVED PAINTED SPRINKLER HEAD AT CELLAR LEVEL. AS PER 102.3 OF THE PLUMBING CODE, MAINTENANCE. INSTALLATIONS, BOTH ... | $0 | $0 | Dec 18, 2024 |
| Oct 9, 2024 | 39127074Y | RESOLVE | CLASS - 2 | EXIT DOOR NOT SELF-CLOSING. OBSERVED NON-SELF-CLOSING DOORS THROUGHOUT BUILDING. THIS CAN LEAD TO A POTENTIAL FIRE AN... | $0 | $0 | Dec 18, 2024 |
| Apr 27, 2023 | 39084920R | RESOLVE | CLASS - 1 | I OBSERVED IN DOB RECORDS THE SUBMITTAL OF A CERTIFICATE OF CORRECTION BY VISHALKUMAR BODALIA AN OFFICER OF THE OWNER... | $0 | $0 | Aug 9, 2023 |
| Apr 27, 2023 | 39084919J | RESOLVE | CLASS - 2 | AS PER COMMISSIONER'S ORDERS TO FILE A C. OF C. THE VIOLATING CONDITIONS MUST BE CORRECTED. ECB# 39064483J ISSUED ON ... | $0 | $0 | Jul 5, 2023 |
| Apr 27, 2023 | 39084858P | RESOLVE | CLASS - 1 | I OBSERVED IN THE 1ST AND 4TH FLOOR THE INSTALLATION OF WIRING AND DATA EQUIPMENT, ALSO NOTED IN THE MAIN ELECTRICAL ... | $1,250 | $0 | Nov 17, 2023 |
| Jun 21, 2022 | 39064484L | RESOLVE | CLASS - 2 | I OBSERVED ON ALL FLOORS NO REMOTE SHUT-DOWN INSTALLED AT THE POINT OF EGRESS TO THE MECHANICAL ROOMS FOR THE GAS-FIR... | $625 | $0 | Oct 26, 2022 |
| Jun 21, 2022 | 39064483J | RESOLVE | CLASS - 1 | I OBSERVED IN THE MAIN ELECTRICAL ROOM EQUIPMENT NOT DEDICATED TO ELECTRICAL DISTRIBUTION EQUIPMENT ONLY , WITH DATA ... | $1,200 | $0 | Oct 26, 2022 |
| Jun 21, 2022 | 39064480Y | RESOLVE | CLASS - 2 | TOP FLOOR REFUSE ROOM HOLES MADE TO RUN NEW CAMERA CABLES INTO ROOM AND THRU FLOOR TO ROOM BELOW. NO FIRE STOP DONE, ... | $0 | $0 | Oct 26, 2022 |
| Sep 24, 2015 | 38238929X | RESOLVE | CLASS - 2 | 70Z10 REPAIR WATER LEAK IN THE PIT. | $0 | $0 | Nov 9, 2015 |
| Aug 6, 2014 | 35098986L | RESOLVE | CLASS - 2 | 3314.8 SCAFFOLDING + "END" TOE BOARDS MISSING.END TOE BOARDS HAVE NOT BEEN PROVIDED FOR PLANKED PLATFORMS @ ROOF LEVE... | $0 | $0 | Sep 22, 2014 |
| Aug 6, 2014 | 35098987N | RESOLVE | CLASS - 2 | 3301.2 INDIVIDUAL WOOD PLANKS WERE OBSERVED @ ALL SITE SCAFFOLDING.THESE WOOD SCAFFOLDING PLANKS WERE NOT(FACED)DOWN ... | $0 | $0 | Sep 22, 2014 |
| Aug 6, 2014 | 35098988P | RESOLVE | CLASS - 2 | 3314.5 PLATFORMS FOR WORKING LEVEL OF SCAFFOLDING ON ROOF HAS NOT BEEN FULLY PLANKED BETWEEN FRONT UPRIGHT & GUARD RA... | $0 | $0 | Sep 22, 2014 |
| Aug 6, 2014 | 35098984H | RESOLVE | CLASS - 2 | 3314.4.4 MATERIAL & DEBRIS WAS OBSERVED ON SUPPORTED SCAFFOLDING THROUGHOUT JOBSITE.WOOD CROSS BRACES,BUCKETS,SECTION... | $0 | $0 | Sep 22, 2014 |
| Jul 1, 2014 | 35098179P | RESOLVE | CLASS - 1 | NO GUARD RAILS/INADEQUATE GUARD RAILS.NOTED:4 STORY BLDG INADEQUATE GUARD RAILS ERECTED IN WINDOW OPENINGS(~3'X3',4'X... | $1,200 | $0 | Aug 18, 2014 |
| Jun 27, 2014 | 35098201M | RESOLVE | CLASS - 1 | ELECTRICAL WORK W/O A PERMIT. NOTE : @ TIME OF MY INSP. CONST. WORK INPROGRESS. I OBSERVED TEMP. ELECTRICAL THROUGHOU... | $800 | $0 | Aug 18, 2014 |
| Apr 19, 2014 | 35092401J | RESOLVE | CLASS - 2 | NO VIEWING PANEL - UPON INSPECTION NOTED VIEWING PANELS NOT PROVIDED ON THE SOLID CONSTRUCTION FENCE ERECTED AT THIS ... | $400 | $0 | Sep 15, 2014 |
| Apr 19, 2014 | 35092400H | RESOLVE | CLASS - 2 | JOB SITE FENCE NOT PAINTED AS PER CODE - UPON INSPECTION NOTED PART OF JOBSITE FENCE (APPROXIMATELY) 60FT NOT PAINTED... | $800 | $0 | Sep 10, 2014 |
| Apr 19, 2014 | 35092149R | RESOLVE | CLASS - 1 | FAILURE TO PROVIDE SIDEWALK SHED - UPON INSPECTION MORE THAN 40 FT HIGH BLDG UNDER CONSTRUCTION THE BLDG UP TO ROOF A... | $2,400 | $0 | Sep 8, 2014 |
| Dec 31, 2013 | 35087337H | RESOLVE | CLASS - 1 | FAILURE TO INSTITUTE/MAINTAIN SAFETY EQUIPMENT MEASURES OR TEMPORARY CONSTRUCTION. NO TOE BOARDS. AT THE TIME OF INSP... | $1,000 | $0 | Feb 24, 2014 |
| Dec 31, 2013 | 35087335Y | RESOLVE | CLASS - 2 | SEC. 3314.6. FAILURE TO MAINTAIN SCAFFOLD W/PROPER FOOTINGS & ANCHORAGE. AT THE TIME OF INSPECTION OBSERVED SUPPORTED... | $0 | $0 | Feb 24, 2014 |
| Dec 31, 2013 | 35087334M | RESOLVE | CLASS - 1 | SEC. 3314.5. PLATFORMS NOT FULLY PLANKED. PIPE SCAFFOLDING BEING USED TO LAY CMU'S ON THE 4TH FLR WERE NOT PLANKED AS... | $1,600 | $0 | Feb 27, 2014 |
| Dec 31, 2013 | 35087336X | RESOLVE | CLASS - 1 | SEC. 3301.7. DESIGN DRAWINGS REQUIRED BY THE PROVISION OF CHAPTER 33 OF NYC BLDG CODE. NO DESIGN DRAWINGS WERE PROVID... | $1,600 | $0 | Feb 27, 2014 |
| Apr 8, 2013 | 35013373N | RESOLVE | CLASS - 1 | PROHIBITED SIGN ON JOB SITE FENCE. NOTED: JOB SITE FENCE ERECTED UNDERJOB #310218056-EQ-FN W/PROHIBITED SIGN "STOP BE... | $0 | $0 | Feb 28, 2014 |
| Apr 8, 2013 | 35013371J | RESOLVE | CLASS - 2 | TEMPORARY EQUIPMENT ON SITE EXPIRED PERMIT. NOTED: JOB SITE FENCE ERECTED UNDER JOB #310218056-EQ-FN EXPIRED 4/1/13. ... | $0 | $0 | Jun 3, 2013 |
| Apr 8, 2013 | 35013372L | RESOLVE | CLASS - 2 | JOB SITE FENCE NOT CONSTRUCTED PURSUANT TO SUBSECTION. NOTED: JOB SITEFENCE ERECTED UNDER JOB #310218056-EQ-FN IS DEF... | $0 | $0 | Jun 3, 2013 |
| May 11, 2011 | 34910848L | RESOLVE | CLASS - 2 | NO CONTRACTOR SIGN POSTED AT TIME OF INSP 310218056NB REM: PROVIDE SIGN W/ REQUIRED INFORMATION | $4,000 | $0 | Jun 27, 2011 |
| May 11, 2011 | 34910847J | RESOLVE | CLASS - 2 | BC3301.9.1 RCNY 27-04 FAILURE TO PROVIDE A SIGN W/ WORDING ANONYMOUSLYREPORT UNSAFE CONDITIONS AT THIS WORK SITE THAT... | $4,000 | $0 | Jun 27, 2011 |