1301 Surf Avenue, Brooklyn • Block 07064 • Lot 0016
73 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Apr 24, 2026 | 39553451M | ACTIVE | CLASS - 2 | BC-3314.8.2- AT THE TIME OF INSPECTION OF A 7-STORY BUILDING, I OBSERVED THE PIPE SCAFFOLD IN PLACE AT EXPOSURE #1, 2... | $2,500 | $2,500 | Jan 12, 2027 |
| Apr 24, 2026 | 39553450K | ACTIVE | CLASS - 2 | AT THE TIME OF INSPECTION OF A 7-STORY BUILDING, I OBSERVED SIDEWALK SHED IN PLACE AT EXP.#1, 2 & 4 AND NOT MAINTAINE... | $2,400 | $2,400 | Jan 12, 2027 |
| Oct 15, 2025 | 39545996M | ACTIVE | CLASS - 2 | OBSERVED, SIDEWALK SHED AROUND JOBSITE PERIMETER NOT MAINTAINED PER CODE: DAMAGED MUDSILL, LOOSE & BEND CROSS BRACE, ... | $2,400 | $2,400 | Jan 30, 2026 |
| Apr 23, 2025 | 35716797H | RESOLVE | CLASS - 2 | PEDESTRIAN PROTECTION DOES NOT MEET CODE SPECIFICATION. OBSERVED AT EXPOSURE 3 DAMAGED AND MUDSILL, LOOSE CROSS BRACE... | $2,400 | $2,400 | May 15, 2026 |
| Jan 4, 2024 | 35679826H | RESOLVE | CLASS - 1 | UNLAW ACT FAILURE TO COMPLY WITH AN ORDER OF THE COMMISSIONER'S.NOTE:OWNER/RESPONDENT FAILED TO COMPLY WITH PREVIOUS ... | $0 | $0 | Jul 23, 2025 |
| Jan 4, 2024 | 35679825X | RESOLVE | CLASS - 2 | SIDEWALK SHED DOES NOT MEET CODE SPECIFICATION.NOTE:OBSERVED AT EXPOSURE 2 PARKING LOT AREA.LOOSE SECTION OF SHED PAR... | $0 | $0 | Apr 4, 2025 |
| Dec 18, 2023 | 39524208J | RESOLVE | CLASS - 2 | OBSERVED SIDEWALK SHED PARAPET WALL COLLAPSED ONTO A ROADWAY AT EXP#1. THIS CONDITION CREATES A HAZARD FOR PUBLIC AND... | $5,000 | $5,000 | Aug 9, 2024 |
| Oct 11, 2023 | 35675201J | RESOLVE | CLASS - 2 | SIDEWALK SHED DOES NOT MEET CODE SPECIFICATION. NOTE OBSERVED AT EXPOSURE 2 PARKING LOT AREA. LOOSE SECTION OF SHED P... | $0 | $0 | Dec 20, 2023 |
| Apr 1, 2022 | 35646246K | RESOLVE | CLASS - 2 | BC 3314.8.2 DEBRIS NETTING NOT ERECTED OPEN SIDES NOTE:AT THE TIME OF MY INSPECTION 7 STORY BUILDING OBSERVED SUPPORT... | $0 | $0 | Aug 17, 2022 |
| Jul 1, 2021 | 35575186M | ACTIVE | CLASS - 2 | PEDESTRIAN PROTECTION DOES NOT MEET CODE SPECIFICATIONS. NOTE:AT THE TIME OF MY INSPECTION OF A SIDEWALK SHED AT THE ... | $2,400 | $0 | Mar 21, 2022 |
| Jun 22, 2021 | 35548858M | RESOLVE | CLASS - 2 | PEDESTRIAN PROTECTION DOES NOT MEET CODE SPECIFICATIONS. AT DOCUMENTEDUNSAFE STRUCTURE,PARAPET WAS NOT CONSTRUCTED AT... | $0 | $0 | Nov 3, 2021 |
| Jun 19, 2021 | 35548857K | RESOLVE | CLASS - 2 | REMOVAL OF PUBLIC PROTECTION FROM UNSAFE FACADE W/O APPROVAL FROM THE DEPT. DOCUMENTED UNSAFE STRUCTURE PARTIALLY REM... | $0 | $0 | Nov 3, 2021 |
| Feb 12, 2021 | 35549087H | RESOLVE | CLASS - 2 | TEMPORARY CONSTRUCTION EQUIPMENT ON SITE-EXPIRED PERMIT.SUPPORTED SCAFFOLD.AT TIME OF INSPECTION I OBSERVED A SUPPORT... | $0 | $0 | Jul 7, 2021 |
| Feb 12, 2021 | 35549088J | RESOLVE | CLASS - 2 | TEMPORARY CONSTRUCTION EQUIPMENT ON SITE-EXPIRED PERMIT-SIDEWALK SHED.AT TIME OF INSPECTION I OBSERVED SIDEWALK SHED ... | $0 | $0 | Jul 7, 2021 |
| Oct 29, 2020 | 35538070H | RESOLVE | CLASS - 2 | FAILURE TO COMPLY WITH COMMISSIONER'S ORDER TO FILE A CERTIFICATE OF CORRECTION WITH THE DEPARTMENT OF BUILDINGS-ON 0... | $0 | $0 | Mar 10, 2021 |
| Oct 29, 2020 | 35538073N | ACTIVE | CLASS - 1 | FAILURE TO TAKE ADEQUATE REGURED MEASUERS TO SECURE PUBLIC SAFETY-UNSAFE FACADE.AT TIME OF INSPECTION OF STRUCTURE DE... | $625 | $0 | Jun 14, 2021 |
| Oct 29, 2020 | 35538072L | ACTIVE | CLASS - 2 | FAILURE TO COMPLY WITH COMMISSIONER'S ORDER TO FILE A CERTIFICATE OF CORRECTION WITH DEPARTMENT OF BUILDINGS.ON 08/11... | $1,250 | $0 | Mar 10, 2021 |
| Oct 29, 2020 | 35538069K | RESOLVE | CLASS - 2 | FAILURE TO COMPLY WITH COMMISSIONER'S ORDER TO FILE A CERTIFICATE OF CORRECTION WITH THE DEPARTMENT OF BUILDINGS.ON 0... | $1,250 | $0 | Mar 10, 2021 |
| Oct 29, 2020 | 35538071J | RESOLVE | CLASS - 2 | FAILURE TO COMPLY WITH COMMISSIONER'S ORDER TO FILE A CERTIFICATE OF CORRECTION WITH THE DEPARTMENT OF BUILDINGS ON 0... | $1,250 | $0 | Mar 10, 2021 |
| Aug 12, 2020 | 35538422M | RESOLVE | CLASS - 1 | WORK DOES NOT CONFORM TO APPROVED CONSTRUCTION DOCUMENTS AND OR APPROVED AMENDMENTS.AT TIME OF INSPECTION OF APPROX 1... | $2,500 | $0 | Mar 8, 2021 |
| Aug 12, 2020 | 35538423Y | RESOLVE | CLASS - 1 | WORK CONTRARY TO MANUFACTURER SPECIFICATION AT TIME OF INSPECTION I OBSERVED APPROX. 13 LIFTS OF SUPPORTED SCAFFOLD A... | $0 | $0 | Mar 8, 2021 |
| Aug 12, 2020 | 35538424X | ACTIVE | CLASS - 1 | BC 3307.6 FAILURE TO PROVIDE PROOF/DOCUMENTATION SIDEWALK SHED INSPECTION.IN ACCORDANCE WITH 3307.6.5.3 &3307.6.510 B... | $2,500 | $0 | Mar 8, 2021 |
| Aug 11, 2020 | 35538419L | ACTIVE | CLASS - 2 | PEDESTRIAN PROTECTION DOES NOT MEET CODE SPECIFICATIONS.AT TIME OF INSPECTION I OBSERVED A SIDEWALK SHED INSTALLED EX... | $2,400 | $0 | Mar 8, 2021 |
| Aug 11, 2020 | 35538418J | RESOLVE | CLASS - 1 | BC 3308.1 FAILURE TO MAINTAIN SAFETY NETTING IN CODE COMPLIANT MANNER.AT TIME OF INSPECTION I OBSERVED THE SAFETY NET... | $2,500 | $0 | Mar 8, 2021 |
| Aug 11, 2020 | 35538417H | RESOLVE | CLASS - 1 | BC 3314 FAILURE TO MAINTAIN SCAFFOLD IN CODE COMPLIANT CONDITION AT TIME OF INSPECTION I OBSERVED DISLODGED PLANKS GU... | $2,500 | $0 | Mar 8, 2021 |
| Aug 11, 2020 | 35538420Z | RESOLVE | CLASS - 1 | BC 3314.1 FAILURE TO SECURE SCAFFOLD IN CODE COMPLIANT MANNER AFTER WEATHER ADVISORY ISSUED 8/2/2020 NOTIFYING OF HIG... | $0 | $0 | Mar 8, 2021 |
| Aug 11, 2020 | 35538421K | RESOLVE | CLASS - 1 | FAILURE TO SAFEGUARD ALL PERSONS AND PROPERTY AFFECTED BY CONSTRUCTIONOPERATIONS.AT TIME OF INSPECTION I OBSERVED A S... | $0 | $0 | Mar 8, 2021 |
| Jul 24, 2020 | 35501151K | RESOLVE | CLASS - 2 | SEC. 3308.5 VERTICAL SAFETY NETTING SHALL BE INSTALLED & MAINTAINED OVER ALL UNENCLOSED PERIMETERS. OBSERVED LOOSE NE... | $625 | $0 | Jun 7, 2021 |
| Jun 3, 2020 | 37019200P | RESOLVE | CLASS - 2 | FAILURE TO FILE ACCEPTABLE AMENDED CYCLE 7A AND 8A REPORT INDICATING CORRECTION OF UNSAFE CONDITIONS DESCRIBED IN INI... | $0 | $0 | Nov 4, 2020 |
| Nov 16, 2017 | 35264800P | RESOLVE | CLASS - 1 | UNLAWFUL ACTS FAILURE TO COMPLY W/AN ORDER OF THE COMMISSIONER.NOTICE OF VIO #35264758K,35264759M,35210262N (1) FOR F... | $2,400 | $0 | Apr 16, 2018 |
| Nov 2, 2017 | 35264758K | RESOLVE | CLASS - 1 | FAILURE TO PROVIDE SAFETY MEASURE SUCH AS SIDE WALK SHEDS,FENCE,ETC.WHERE REQUIRE TO PROTECT AND SECURE PUBLIC SAFETY... | $6,000 | $0 | May 21, 2018 |
| Nov 2, 2017 | 35264759M | RESOLVE | CLASS - 2 | BC27-28/BC-MISC.MISC.VIOLATION.SIDEWALK SHED DOES NOT MEET CODE SPECIFICATION.NOTE:PEDESTRIAN PROTECTION DOESNT MEET ... | $400 | $0 | May 21, 2018 |
| Nov 1, 2017 | 35285369J | RESOLVE | CLASS - 1 | WATCHPERSON AND FLAGPERSON . NOTED: AT TIME OF INSPECTION WORKERS INSTALLING SHED ON STILLWELLL AVE WITH PART INSTALL... | $1,600 | $0 | Dec 18, 2017 |
| Nov 1, 2017 | 35285370R | RESOLVE | CLASS - 2 | REMOVAL OF SHED OR PROTECTION MEASURE WITHOUT DEPARTMENT APPROVAL NOTED: AT TIME OF INSPECT SHED ON EXP #1 SURF AVE W... | $400 | $0 | Dec 18, 2017 |
| Jun 29, 2017 | 35270993L | ACTIVE | CLASS - 2 | FAILURE TO MAINTAIN BLDG WALLS OR APPURTENACES. NOTED: EXP#4 BRICK WALL HAS LARGE AREA OF BRICKS SPALLING STUCCO & PA... | $500 | $0 | Mar 12, 2018 |
| May 4, 2017 | 35244299M | ACTIVE | CLASS - 1 | FAILURE TO MAINTAIN BLDG WALL(S)OR APPURTENANCES.NOTED:@EXP#4,BRICK WALL HAS LARGE AREA OF BRICK SPALLING,STUCCO&PAIN... | $1,000 | $0 | Sep 18, 2017 |
| Feb 9, 2017 | 35200353J | RESOLVE | CLASS - 2 | PEDESTRIAN PROTECTION DOES NOT MEET CODE SPEC 3307.6.4.8 THE UNDERSIDEOF SIDEWALK SHED SHALL BE ILLUMINATED AT ALL TI... | $10,000 | $0 | Mar 27, 2017 |
| Jan 25, 2017 | 35210262N | RESOLVE | CLASS - 1 | FAILURE TO PROVIDE ADEQUATE SAFETY MEASURES/SIDEWALK SHED, NEETING,ETCWHERE REQUIRED TO PROTECT AND SECURE PUBLIC SAF... | $12,000 | $0 | Mar 13, 2017 |
| Nov 7, 2016 | 37001796J | ACTIVE | CLASS - 2 | FAILURE TO FILE ACCEPTABLE AMENDED REPORT INDICATING CORRECTION OF UNSAFE CONDITIONS DESCRIBED IN INITIAL LOCAL LAW 1... | $800 | $0 | May 3, 2017 |
| Sep 8, 2016 | 35199519P | RESOLVE | CLASS - 2 | PEDESTRIAN PROTECTION DOESN'T MEET CODE SPECS.NOTE:OBSERVED SIDEWALK SHED IS IN PLACE @EXP#1 (SURF AVE) & EXP#3 (STIL... | $800 | $0 | Jan 18, 2017 |
| Jan 6, 2016 | 35168182R | RESOLVE | CLASS - 1 | SEC. 3307.6.5 SIDEWALK SHED ERECTED UNDER JOB#302140966 HAS NO ARTIFICIAL ILLUMINATION PROVIDED AT AREA UNDER SHED TH... | $8,000 | $0 | Feb 29, 2016 |
| Jan 6, 2016 | 35168181P | RESOLVE | CLASS - 1 | SEC. 3307.6.5 SIDEWALK SHED ERECTED UNDER JOB#320445185 HAS NO ARTIFICIAL ILLUMINATION PROVIDED AT AREA UNDER SHED TH... | $8,000 | $0 | Feb 29, 2016 |
| Dec 11, 2015 | 36023841K | ACTIVE | CLASS - 2 | FAILURE TO FILE AN ACCEPTABLE AMENDED CYCLE 7 REPORT TO THIS DEPARTMENT INDICATING CORRECTION OF UNSAFE CONDITIONS DE... | $4,000 | $0 | May 23, 2016 |
| Apr 15, 2015 | 35131783N | RESOLVE | CLASS - 2 | TEMP CONSTRUCTION EQUIPMENT ON SITE W/EXPIRED PERMIT. NOTED:AT TIME OFINSPECTION SIDEWALK SHED INSTALLED ON EXP#1 AND... | $4,000 | $0 | Jun 8, 2015 |
| Jul 12, 2013 | 35015285M | RESOLVE | CLASS - 2 | SIDEWALK SHED DOES NOT MEET CODE SPECIFICATION. NO ILLUMINATION UNDER SHED 8:25PM. RMDY: CONFORM SHED TO CODE SPECIFI... | $2,400 | $0 | Aug 26, 2013 |
| Oct 30, 2012 | 34940559M | ACTIVE | CLASS - 1 | FAILURE TO MAINTAIN BLDG WALLS OR APPURTENANCES. NOTED:HANGING SIGN INDANGER OF FALLING TO SIDEWALK.SIGN IN DANGER OF... | $1,030 | $0 | Dec 17, 2012 |
| Dec 29, 2011 | 36018121X | ACTIVE | CLASS - 2 | FAILURE TO FILE AN AMENDED 7TH ROUND REPORT ACCEPTABLE TO THIS DEPT INDICATING CORRECTION OF UNSAFE CONDITIONS DESCRI... | $800 | $0 | May 14, 2012 |
| Dec 29, 2011 | 36017676P | ACTIVE | CLASS - 2 | FAILURE TO FILE AN AMENDED 6TH ROUND REPORT ACCEPTABLE TO THIS DEPT INDICATING CORRECTION OF UNSAFE CONDITIONS DESCRI... | $2,000 | $0 | May 14, 2012 |
| Sep 30, 2011 | 34929734N | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN BUILDING WALLS OR APPURTENANCES. NOTE: SIGN LETTERS ARE LOOSE & SEPARATING FROM BASE. LETTERS C &... | $500 | $0 | Apr 16, 2012 |
| Jun 14, 2011 | 36017152Y | ACTIVE | CLASS - 2 | FAILURE TO FILE AN AMENDED 6TH ROUND REPORT ACCEPTABLE TO THIS DEPT INDICATING CORRECTION OF UNSAFE CONDITIONS DESCRI... | $8,000 | $0 | Sep 12, 2011 |