| Issued | Class | Status | Violation | Apartment | Correct by |
|---|---|---|---|---|---|
| Sep 11, 2024 | A | VIOLATION CLOSED | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10 SQ FEET AT NORTH WA... | 1E | Dec 15, 2024 |
| Sep 10, 2024 | B | DEFECT LETTER ISSUED | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... APPROXIMATELY 8 SQ FT AT BALCONY... | 7H | Oct 15, 2024 |
| Aug 28, 2024 | B | NOT COMPLIED WITH | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT NORTH AND SOUTH ... | 1E | Oct 2, 2024 |
| Aug 28, 2024 | A | NOT COMPLIED WITH | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE GROUT AT WEST WALL IN THE BATHROOM L... | 1E | Dec 1, 2024 |
| Aug 28, 2024 | B | VIOLATION CLOSED | § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). DEFECTIVE IN THE ENTIRE APARTMENT LOCATED... | 1E | Oct 2, 2024 |
| Aug 28, 2024 | C | NOT COMPLIED WITH | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT SOUTH WALL IN CL... | 1E | Sep 3, 2024 |
| Aug 28, 2024 | B | NOT COMPLIED WITH | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE VINYL FLOOR IN THE 4th ROOM FROM EAS... | 1E | Oct 2, 2024 |
| Aug 28, 2024 | B | NOT COMPLIED WITH | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE 2... | 1E | Oct 2, 2024 |
| Aug 28, 2024 | B | VIOLATION CLOSED | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE 2nd ROOM FRO... | 1E | Oct 2, 2024 |
| Aug 28, 2024 | B | VIOLATION CLOSED | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT NORTH WALL IN THE 3rd ROOM ... | 1E | Oct 2, 2024 |
| Aug 26, 2024 | B | NOT COMPLIED WITH | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING AND WALLS I... | 1E | Sep 30, 2024 |
| Aug 26, 2024 | B | FIRST NO ACCESS TO RE- INSPECT VIOLATION | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING AND EAST WA... | 5C | Sep 30, 2024 |
| Aug 26, 2024 | B | FIRST NO ACCESS TO RE- INSPECT VIOLATION | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR WINDOW RECESS AT EA... | 5C | Sep 30, 2024 |
| Aug 26, 2024 | B | FIRST NO ACCESS TO RE- INSPECT VIOLATION | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE SPRING BALANCE AT LOWER SASH WINDOW AT SOTH WAL IN ... | 5C | Sep 30, 2024 |
| Aug 26, 2024 | B | FIRST NO ACCESS TO RE- INSPECT VIOLATION | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE INSULATION RUBBER SEEAL AT GLASSES OF UPPER WINDOW ... | 5C | Sep 30, 2024 |
| Aug 26, 2024 | B | FIRST NO ACCESS TO RE- INSPECT VIOLATION | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR WINDOW RECESS AT SO... | 5C | Sep 30, 2024 |
| Aug 26, 2024 | B | FIRST NO ACCESS TO RE- INSPECT VIOLATION | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE SPRING BALANCE AT LOWER SASH WINDOW AT EAST WALL IN... | 5C | Sep 30, 2024 |
| Aug 26, 2024 | B | FIRST NO ACCESS TO RE- INSPECT VIOLATION | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE ELECTRICAL OUTLET AT NORTH WALL IN THE KITCHEN LOCA... | 5C | Sep 30, 2024 |
| Aug 26, 2024 | B | FIRST NO ACCESS TO RE- INSPECT VIOLATION | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING AND EAST WA... | 5C | Sep 30, 2024 |
| Aug 26, 2024 | B | FIRST NO ACCESS TO RE- INSPECT VIOLATION | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR WINDOW RECESS AT EA... | 5C | Sep 30, 2024 |
| Aug 26, 2024 | B | FIRST NO ACCESS TO RE- INSPECT VIOLATION | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE SPRING BALANCE AT LOWER SASH WINDOW AT SOUTH WALL I... | 5C | Sep 30, 2024 |
| Aug 26, 2024 | B | FIRST NO ACCESS TO RE- INSPECT VIOLATION | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR WINDOW RECESS AT SO... | 5C | Sep 30, 2024 |
| Aug 26, 2024 | B | FIRST NO ACCESS TO RE- INSPECT VIOLATION | § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 5C, 4th STOR... | 5C | Sep 30, 2024 |
| Aug 26, 2024 | B | FIRST NO ACCESS TO RE- INSPECT VIOLATION | § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). DEFECTIVE IN THE ENTIRE APARTMENT LOCATED... | 5C | Sep 30, 2024 |
| Aug 21, 2024 | B | NOT COMPLIED WITH | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT SOUTH WALL APPRX 1 SQUARE FEE... | 2D | Sep 25, 2024 |
| Aug 2, 2024 | C | VIOLATION DISMISSED | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 5B, 5th ... | 5B | Aug 28, 2024 |
| Aug 2, 2024 | B | VIOLATION DISMISSED | § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 5B, 5th STOR... | 5B | Sep 6, 2024 |
| Jul 30, 2024 | B | FIRST NO ACCESS TO RE- INSPECT VIOLATION | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WALL CABINET AT NORTH WALL IN THE KI... | 4L | Sep 3, 2024 |
| Jul 30, 2024 | B | FIRST NO ACCESS TO RE- INSPECT VIOLATION | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT EAST WALL IN THE 1st ROOM F... | 4L | Sep 3, 2024 |
| Jul 30, 2024 | B | FIRST NO ACCESS TO RE- INSPECT VIOLATION | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE 1st ROOM FRO... | 4L | Sep 3, 2024 |
| Jul 30, 2024 | A | FIRST NO ACCESS TO RE- INSPECT VIOLATION | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT ALL PEELING PAINT SURFACES I... | 4L | Nov 2, 2024 |
| Jul 30, 2024 | C | FIRST NO ACCESS TO RE- INSPECT VIOLATION | § 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) IN ACCORDANCE WITH THE SPECIFICAT... | 4L | Aug 25, 2024 |
| Jul 5, 2024 | B | VIOLATION CLOSED | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE WITH NEW THE ROTTED WOOD DOOR THAT IS IRREPARABLE L... | 7H | Aug 9, 2024 |
| Jul 5, 2024 | B | DEFECT LETTER ISSUED | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 16 SQ FT. AT DOOR LEAD... | 7H | Aug 9, 2024 |
| Jul 3, 2024 | B | VIOLATION CLOSED | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR ALL WALLS AND CEILI... | 7H | Aug 7, 2024 |
| Jul 3, 2024 | C | VIOLATION CLOSED | § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF KEY OPERATED LOCK AT DOOR OF ROOM LEADING TO FIRE E... | 7H | Jul 9, 2024 |
| Jul 3, 2024 | C | VIOLATION CLOSED | § 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) IN ACCORDANCE WITH THE SPECIFICAT... | 7H | Jul 29, 2024 |
| Jul 3, 2024 | C | DEFECT LETTER ISSUED | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 7H, 6th ... | 7H | Jul 29, 2024 |
| Jul 3, 2024 | C | VIOLATION CLOSED | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... 12 SQ.FT AT SOUTH WALL, 1 SQ.FT ... | 7H | Jul 29, 2024 |
| Jun 25, 2024 | B | VIOLATION CLOSED | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING AND ALL... | 7H | Jul 30, 2024 |
| Jun 25, 2024 | C | VIOLATION CLOSED | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... APPROXIMATELY 35 SQ. FEET AT CEI... | 7H | Jul 21, 2024 |
| May 23, 2024 | B | NOT COMPLIED WITH | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE 1... | 1E | Jun 27, 2024 |
| May 23, 2024 | C | VIOLATION CLOSED | § 27-2005, 2007 ADM CODE REMOVE DEVICE PREVENTING DOOR FROM BEING SELF-CLOSING PERMANENTLY INSTALLED HOOK AT DOOR LEA... | — | Jun 6, 2024 |
| May 23, 2024 | C | VIOLATION CLOSED | § 27-2005, 2007 ADM CODE REMOVE DEVICE PREVENTING DOOR FROM BEING SELF-CLOSING PERMANENTLY INSTALLED KICKSTAND AT DOO... | — | Jun 6, 2024 |
| May 23, 2024 | B | NOT COMPLIED WITH | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC TILES AT NORTH AND WEST WALL... | 1E | Jun 27, 2024 |
| May 23, 2024 | B | VIOLATION CLOSED | § 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT BATHTUB IN THE BATHROOM LOCATED AT APT 1E, 2nd APARTM... | 1E | Jun 27, 2024 |
| May 23, 2024 | B | VIOLATION CLOSED | § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). DEFECTIVE IN THE ENTIRE APARTMENT LOCATED... | 1E | Jun 27, 2024 |
| May 21, 2024 | C | VIOLATION CLOSED | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CL... | — | Jun 16, 2024 |
| May 21, 2024 | C | VIOLATION CLOSED | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CL... | — | Jun 4, 2024 |
| May 21, 2024 | C | VIOLATION CLOSED | § 27-2005, 2007 ADM CODE REMOVE DEVICE PREVENTING DOOR FROM BEING SELF-CLOSING CONSISTING OF HOOK AND EYE (INSTALLED ... | — | Jun 4, 2024 |