Jul 15, 2025 39153705K RESOLVE CLASS - 2 FAILURE TO COMPLY WITH THE DEPARTMENT, TO GET A FINAL INSPECTION UNDER PERMIT #B00554225-I1-GC, WHICH EXPIRED 01/25/2... $1,250 $0 Nov 10, 2025
May 1, 2025 39146675N RESOLVE CLASS - 2 WORK WITHOUT A PERMIT, I OBSERVED AT TIME OF INSPECTION, IN 1ST FLOOR (3)COMMERCIAL GAS DRYERS INSTALLED, NO PERMIT O... $3,125 $3,125 Dec 21, 2026
Aug 26, 2024 39123074X RESOLVE CLASS - 2 MISALIGNED 1ST FLOOR HOIS6TWAY DOOR ACCESS HOLE. REPLACE WORN HOISTWAY DOOR GIBS WHERE NEEDED. $0 $0 Nov 6, 2024
Mar 31, 2023 39082820K RESOLVE CLASS - 1 CLASS 2: REPAIR IN-CAR ALARM., REPAIR IN-CAR EMERGENCY STOP SWITCH ALARM., CLASS 1: CEASE USE ITEMS. ADJUST LOBBY FLO... $1,250 $0 Aug 20, 2024
Aug 11, 2020 39026742H RESOLVE CLASS - 2 MISSING IN CASE OF FIRE SIGNS. REPLACE HOISTWAY DOOR GIBS WHERE NEEDED. SECURE HOISTWAY DOOR GIBS WHERE NEEDED. UNREA... $0 $0 Dec 16, 2020
Jul 16, 2020 35409318L RESOLVE CLASS - 1 UNLAWFULLY CONTINUED WORK WHILE ON NOTICE OF A STOP WORK ORDER.AT TIMEOF INSPECTION,OBSERVED FACADE REPAIRS AT EXPO 1... $0 $0 Jan 8, 2021
Jul 16, 2020 35409319N RESOLVE CLASS - 1 FAILURE TO SAFEGUARD ALL PERSONS AND PROPERTTY AFFECTED BY CONSTRUCTION OPERATIONS.ONGOING FACADE REPAIRING REQUIRES ... $0 $0 Jan 8, 2021
Jul 15, 2020 35537137Z RESOLVE CLASS - 2 FAILED TO NOTIFY DEPT PRIOR TO USE/INSTALLATION OF C-HOOKS/OUTRIGGER BEAMS IN CONNECTION W/SUSPENDED SCAFFOLD. REMEDY... $0 $0 Nov 25, 2020
Sep 15, 2017 35278463K RESOLVE CLASS - 2 FAILURE TO COMPLY WITH THE COMMISSIONERS ORDER CONTAINED IN SUMMONS/VIOLATION #35236564Y ISSUED ON 08/08/17 AND TO FI... $0 $0 Oct 30, 2017
Aug 8, 2017 35236564Y RESOLVE CLASS - 1 FAILUR ETO TO SAFEGUARD ALL PERSONS & PROPERLY AFFECTED BY CONST OPS NOTED:(1) WORK IN PROGRESS UNDER PERMIT #3216132... $10,000 $0 Mar 5, 2018
Apr 9, 2015 35150894J RESOLVE CLASS - 2 SEC. 3314.4.1.5 NOTIFUCATION. NOTED: AT TIME OF INSPECTION ALL EQUIPMENT/HANGING SCAFFOLDS HAVE BEEN REMOVED FROM JOB... $4,000 $0 Jun 1, 2015
Sep 19, 2014 35111639K RESOLVE CLASS - 2 FAILURE TO MAINTAIN BLDG WALL(S) OR APPURTENANCES NOTED AT SOUTHWEST FACING SIDE OF EXTERIOR BRICK WALL CONSIST OF VE... $250 $0 Mar 23, 2015
Apr 1, 2014 35091251Z RESOLVE CLASS - 1 WORK W/O A PERMIT NOTED:AT 1ST FLR LVL GRADE REAR LAUNDRY & STORAGE ROOMS A 4W'X4'DX40'L SECTION OF CONCRETE SLAB FLR... $800 $0 May 19, 2014
Feb 2, 2010 38208638Z RESOLVE CLASS - 2 03D6.08A1.16T7.70O2.32H10.97D6.03 HANDRAIL LOOSE 08 ADJUST LEVELING 16 NUMBER HOISTWAY DOORS 70 CLEAN PIT 32 CAR SHOE... $0 $0 Mar 29, 2010
Oct 15, 2009 34795447J RESOLVE CLASS - 2 WORK DOES NOT CONFORM TO APPROVED CONST. DOCUMENTS & /OR APPROVED AMENDMENTS FOR ALT II APPLICATION # 310199567. NON-... $0 $0 Dec 7, 2009
Dec 8, 2008 38199463Y RESOLVE CLASS - 2 98BB05, 100BB05, 45O02, 56Y13, 60X07, 14M07, 41T07, 52M07, 15M07, 03M07, 03M07, 70O02. 100BB05- EXPIRED 2YR TEST TAG.... $500 $0 Sep 4, 2009
Jan 24, 2008 38179974H RESOLVE Non-Hazardous 14M07,15M07,59X10,44M07,39B09,17H11,03M07.44M-GOVERNOR OVER SPEED SWITCH MISSING.39B-REMOVE WOOD FROM MACH ROOM.17H-7... $350 $0 Mar 20, 2008
Aug 22, 2006 38161051Y RESOLVE Non-Hazardous 57-H-10/55-Y-10/15-M-07/39-L-01/39-O-02/41-G-10/44-M-07/57-GEAR GRINDING ON WORM/38-LIGHTING/39-BROKEN GLASS/44-GOV M... $180 $0 Oct 2, 2006
Jun 14, 2006 32051644Y RESOLVE Non-Hazardous B4B,36,BQ9,16/B4B-BOILER REMOVED-NEW BOILER INSTALLED ALL SAFETIES REMOVED FROM EXISTING BOILER W/O PERMITS OR PLANS-... $1,050 $0 Aug 28, 2006
Jun 14, 2006 32051645X RESOLVE Non-Hazardous BQ9/29B/38/50C/50C/B4B/36/16/50B/50D. 50A- HAZARDOUS-RAN GAS LINES TO BOILER W/O PERMIT OR INSPECTION REMOVE IMMEDIAT... $650 $0 Aug 28, 2006
Dec 12, 2005 38164050X RESOLVE Non-Hazardous 57R05/55Y13/55E10/55O02/44O02/59X10/41G11/84M07/ 57-R-05;INSTALLED W/O PERMIT:REMEDY, FILE APPL.,OBTAIN PERMIT HAVE D... $0 $0 Mar 6, 2006
Aug 10, 2005 34487808L RESOLVE Hazardous FAILURE TO PROVIDE ADEQUATE PROTECTION ON FOR SIDEWALKS AND WALKWAYS DURING CONSTRUCTION OPERATIONS, LOT OF PIECES OF... $2,000 $0 Mar 28, 2006
Jul 26, 2005 38153985H RESOLVE Non-Hazardous 57R05-INSTALLED (WORM/GEAR/BEARINGS) W/O PERMIT. REMEDY FOR (WORM/GEAR/BEARING) AND OBTAIN PERMIT AND HAVE TESTED BY ... $2,500 $0 Sep 12, 2005
Mar 25, 2003 38136828J RESOLVE Non-Hazardous 8V1-52#11-81BB5-17H12-80I12-80#12-9B11. 8-V-6 FLOOR 52-# NOISY MOTOR IN SLOW DOWN 81-BB-STAMP FOR DATE ILLEGAIBLE 17-... $180 $0 Aug 18, 2003
Nov 30, 1999 38092037L RESOLVE Non-Hazardous 75R05,57O02,35M07,50M07. 35M- NO LIGHT IN MOTOR ROOM 50M -COUNTER WIRES ON MOTOR $0 $0 Jan 10, 2000
Jan 26, 1999 38083290K RESOLVE Non-Hazardous 40B07, 75U05,. 40-PROVIDE UP OVERSPEED TRIPPING SWITCH AND CERTIFY TO PROPER CALIGRATION AS PER ANSI. A17.1 SECTIONS ... $0 $0 Mar 15, 1999
Apr 29, 1998 38073011J RESOLVE Non-Hazardous 40B57O 40-B-07-PROVIDE UP OVERSPPED TRIPPING SWITCH AND CERTIFY TO PROPER CALIBRATION AS PER ANSI A; 17I SECTIONS 206... $0 $0 Jun 15, 1998
May 12, 1995 38049019Y RESOLVE Non-Hazardous 50J, 570, 52H, 52H. ELIMINATE RUMBLING NOISE OR VIBRATION INSIDE OF GEARCASE. RENEW OR REPAIR "SCORED" BRAKE COUPLING. $0 $0 Jul 17, 1995
Jan 10, 1992 38010767L RESOLVE Non-Hazardous 10L;13D;35Y;73T;74#; 73.FIVE YR TEST AND FILE ELEV 3.. 74. ID OF ELEVATOR CO. IN MOTOR ROOM. $0 $0 Feb 24, 1992
May 22, 1991 38011979H RESOLVE Non-Hazardous 10L,13D,35Y,73T,74#,#73 PERFORM 5 YEAR TEST AND FILE FORM ELV #3 #74 PROVIDE I.D. OF ELEVATOR CO ON MOTOR ROOM. $0 $0 Jan 6, 1992