2122-2128 Coyle Street, Brooklyn
Brooklyn • Block 07367 • Lot 0011 • Zip: 11229
Condition
What the city currently has open against this building, counted from its own records.
Address
Land use and zoning
Building
Latest assessment
Neighborhood
The area this lot falls inside, and the commute Hoodkit measures from it.
Getting around
Estimated 4 days ago- Downtown Brooklyn 43 min 8 walking, 35 riding
- Union Square 47 min 8 walking, 39 riding
- Times Square 51 min 8 walking, 43 riding
- Fulton Street 51 min 8 walking, 43 riding
- Grand Central 57 min 8 walking, 49 riding
- Penn Station 58 min 8 walking, 50 riding
Around this address
Transit and places within 0.5 miles of the lot.
Getting out
Bus
Activity
Sales, filings, permits and violations from every dataset, in one order.
2026
-
CLASS - 1
AT THE TIME OF MY INSPECTION OF A 7 STORY NEW BUILDING AT FOUNDATION/EXCAVATION PHASE, I OBSERVED RAKERS AND WALERS I...
-
CLASS - 1
AT THE TIME OM MY INSPECTION OF A 2 STORY BUILDING, I OBSERVED ALTERATION AND DEMOLITION JOBSITE, UPON REQUEST FOR CO...
-
CLASS - 1
BC 3307.7 AT THE TIME OM MY INSPECTION OF A 2 STORY BUILDING, I OBSERVED DEMOLITION ACTIVITIES IN PROGRESS AND CONSTR...
-
CLASS - 1
BC 3307.7 AT THE TIME OM MY INSPECTION OF A 1 STORY BUILDING, I OBSERVED DEMOLITION ACTIVITIES IN PROGRESS AND CONSTR...
-
CLASS - 1
RESPONDING TO AN INCIDENT THAT GAS LINE DAMAGE DURING DEMOLITION ACTIVITIES. INVESTIGATION REVEAL THAT EXCAVATOR WAS ...
-
CLASS - 1
BC 3303.2 AT THE TIME OF MY INSPECTION RESPONDING TO AN INCIDENT THAT GAS LINE DAMAGE DURING DEMOLITION ACTIVITIES. I...
2025
-
DOB violation Jan 8, 2025
AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
2024
-
DOB violation Dec 1, 2024
EGRADE-FAILURE TO POST ENERGY GRADE/SCORE NONE
FAILURE TO DISPLAY ENERGY EFFICIENCY SCORE AND ENERGY EFFICIENCY GRADE AS PER ADCODE SEC. 28-309.12.3
-
DOB violation Sep 23, 2024
LBLVIO-LOW PRESSURE BOILER BOILER REQUIRED
VIOLATION ISSUED-FAILURE TO FILE 2023 EXTERNAL LOW PRESSURE INSPECTION
-
Alteration Type III
BPP WORK FOR A FRONTAGE OF 360 FT AS PER PLANS FILED. FILED IN CONJUNCTION WITH NB B00915426-I1.
2023
-
DOB violation Dec 1, 2023
EGRADE-FAILURE TO POST ENERGY GRADE/SCORE NONE
FAILURE TO DISPLAY ENERGY EFFICIENCY SCORE AND ENERGY EFFICIENCY GRADE AS PER ADCODE SEC. 28-309.12.3
-
DOB violation Jun 30, 2023
LBLVIO-LOW PRESSURE BOILER BOILER REQUIRED
VIOLATION ISSUED-FAILURE TO FILE 2020 EXTERNAL LOW PRESSURE INSPECTION
-
DOB violation Jun 20, 2023
LBLVIO-LOW PRESSURE BOILER BOILER REQUIRED
VIOLATION ISSUED-FAILURE TO FILE 2018 EXTERNAL LOW PRESSURE INSPECTION
2021
-
Alteration Type I
SUBSEQUENT DOCUMENT TO DO STRUCTURAL WORK IN CONJUNCTION WITH ARCHITECTURAL DRAWINGS UNDER APPLICATION NUMBER: 320915079
2017
-
Alteration Type II
INTERIOR RENOVATION WITH NEW STOREFRONT AT EXISTING COMMERCIAL BUILDING. WORK TO INCLUDE GENERAL CONSTRUCTION, PLUMBI...
-
Alteration Type I
SUBDIVIDE ONE TAX LOT INTO TWO TAX LOTS (NO WORK APPLICATION)
2016
-
Subdivision Improved
SUBDIVISION IMPROVED PROPERTY: ONE ZONING LOT INTO TWO TAX LOTS
-
Alteration Type III
ERECT A BUSINESS ACCESSORY AWNING, NO CHANGE IN USE, EGRESS OR OCCUPANCY.
The most recent 6 events from each dataset, so no one source takes the axis. Each tab holds the full record.
Property Contacts
Contact information aggregated from multiple government sources
Building Permits
Owner information from Department of Buildings filings
Recent Building Permits
Owner information from recent DOB NOW filings
Deed Records
Parties from ACRIS deed and mortgage records
Property Records
Owner information from assessment and PLUTO records