ECB violations
1674 New York Avenue, Brooklyn • Block 07560 • Lot 0001
14 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Apr 11, 2024 | 37028082H | ACTIVE | CLASS - 2 | FAILURE TO SUBMIT AN ACCEPTABLE REQUIRED CYCLE 9B REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WA... | $1,250 | $0 | Jul 24, 2024 |
| Aug 31, 2023 | 39093831J | RESOLVE | CLASS - 2 | SHORTE HOIST ROPES TO PROVIDE MINIMUM OF 6 INCHES OF RUNBY BETWEEN COUNTER-WEIGHT AND SPRING BUFFER., REPAIR MOTOR RO... | $0 | $0 | Nov 8, 2023 |
| May 19, 2023 | 39086734M | ACTIVE | CLASS - 2 | BOILER WATER LEAKING FROM OUTSIDE SHELL REAR OF BOILER;CORRECT VIOLATION AND SUBMIT THE CERTIFICATE OF CORRECTION | $3,125 | $3,125 | Mar 18, 2024 |
| May 19, 2023 | 35646974Z | RESOLVE | CLASS - 2 | WORK WITHOUT A PERMIT.NOTED:IN APT#5S DROP CEILING CREATED AT 1 5/8 STUD + TMACK + SHEETROCK INSTALLED TO CONCEAL NEW... | $1,250 | $0 | Aug 9, 2023 |
| Feb 15, 2023 | 39079789Y | RESOLVE | CLASS - 1 | SHORTEN HOIST ROPES TO PROVIDE MINIMUM OF 6 INCHES OF RUNBY BEWEEN COUNTER-WEIGHT AND SPRING BUFFER., PROVIDE PROPER ... | $1,250 | $1,250 | Apr 26, 2023 |
| Feb 15, 2023 | 39079790L | RESOLVE | CLASS - 2 | SHORTEN HOIST ROPES TO PROVIDE MINIMUM OF 6 INCHES RUNBY BETWEEN COUNTER-WIEGHT AND SPRING BUFFER. | $0 | $0 | Apr 26, 2023 |
| Sep 29, 2020 | 39029522J | RESOLVE | CLASS - 1 | NO DOOR LOCK MONITORING INSTALLED IN THIS CONTROLLER AS MANDATED BY 3.10.12 OF APPENDIX K3 OF THE 2014 NYCBC. THIS IS... | $3,125 | $3,125 | Feb 3, 2021 |
| Jan 15, 2019 | 39001123H | RESOLVE | CLASS - 1 | CEASE USE ITEMS: 1) INOPERATIVE ZONE LOCK RESTRICTOR 2) GAPS ON BOTH BRAKE PADS EXCEEDING OVER 40% OF SURFACE. 125% B... | $1,250 | $1,793 | Mar 5, 2019 |
| Dec 5, 2007 | 38180306K | RESOLVE | Non-Hazardous | 51H17. 51-H CWT LANDING, SHORTEN ROPES. | $0 | $0 | Jan 28, 2008 |
| Dec 9, 2004 | 34443289Y | RESOLVE | Non-Hazardous | GAS VENT SYSTEMS: VENTS FROM DRYERS IN LAUNDRY ROOM WITHIN 10 OF APARTMENTS 1D & 1E 1ST FL. & VENT GOES IN PLASTIC WA... | $0 | $0 | Jan 24, 2005 |
| Apr 25, 2003 | 34384513M | RESOLVE | Non-Hazardous | FAILURE TO SUBMIT A FIFTH ROUND TECHNICAL REPORT: PERIORDIC INSPECTION OF EXTERIOR WALLS AND APPURTENANCES AS REQUIRE... | $0 | $0 | Apr 26, 2004 |
| Jul 27, 1993 | 34096075P | RESOLVE | Hazardous | FAILURE TO SUBMIT A 3RD ROUND TECHNICAL REPORT PERIODIC INSPECTION OF EXTERIOR WALL AND APPURTENANCES AS REQUIRED BY ... | $0 | $0 | Oct 25, 1993 |
| Jun 8, 1991 | 38012064Y | RESOLVE | Non-Hazardous | 73#; 73.PERFORM 5YR TEST,PROPERLY TAG,DEVICE AND FILE FORM ELEV.3 | $0 | $0 | Jul 6, 1992 |
| Jun 7, 1991 | 38012062K | RESOLVE | Non-Hazardous | 73#; 73.PERFORM 5YR TEST,PROPERLY TAG DEVICE AND FILE FORM ELEV.3. | $0 | $0 | Jan 6, 1992 |