Sales, filings, permits and violations from every dataset, in one order.
2025
-
HPD violation Mar 17, 2025
Class A
§ 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT ALL WALLS AND CEILINGS THROU...
-
HPD violation Mar 17, 2025
Class B
§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING BY THE SMOKE DETEEC...
-
HPD violation Mar 17, 2025
Class A
§ 329, M/D LAW AND DEPT. RULES AND REGS. PROVIDE A COMPLETED CERTIFICATE OF INSPECTION VISITS IN A PROPER FRAME AT OR...
2024
-
HPD violation Nov 29, 2024
Class C
§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE K...
-
HPD violation Nov 29, 2024
Class C
§ 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... GREATER THAN 30 SQUARE FEET AT C...
-
HPD violation Nov 29, 2024
Class C
§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE KITCHEN LOCA...
2019
-
New Building
PROPOSED NEW 4 STORY, CELLAR & PENTHOUSE RESIDENTIAL BUILDING.
-
Alteration Type II
APPLICATION FILED HEREWITH FOR THE INSTALLATION OF AUTOMATIC SMOKE DETECTION AND SPRINKLER FIRE ALARM SYSTEM IN CONJU...
-
Alteration Type II
SOE APPLICATION FILED HEREWITH IN CONJUNCTION WITH NEW BUILDING, JOB# 321695876.
-
CLASS - 1
INADEQUATE HOUSEKEEPING ATTIME OF INSPECTION OBSERVED INADEQUATE HOUSEKEEPING CONSISTING OF DEBRIS & CONSTRUCTION MAT...
-
CLASS - 1
FAILURE TO SAFEGUARD. AT TIME OF INSPECTION OBSERVED SUPPORTED SCAFFOLD IN PLACE AT ACTIVE JOB SITE EXP#3 W/2 WORKERS...
-
CLASS - 2
SEC. 3301.2 FAILURE TO MAINTAIN AT TIME OF INSPECTION OBSERVED STAIR INFILLS NOT INSTALLED. THIS CREATES A TRIP & FAL...
-
CLASS - 2
SEC. 3301.1.3 MANUFACTOR SPECIFICATION. AT TIME OF INSPECTION OBSERVED GRINDER(POWER TOLL)IN USE W/O HANDLE. GRINDER ...
2018
-
CLASS - 1
3301.7 DESIGN DRAWING. NOTE AT TIME OF INSPECTION OF A 4 STORY N.B. UNDER CONSTRUCTION AT FOUNDATION LEVEL. ACTIVE JO...
-
DOB violation Aug 23, 2018
C-CONSTRUCTION OTHER OPTIONAL
2017
2014
-
CLASS - 1
WORK W/O PERMIT. NOTED: AT RER OF PREMISE AN APPROX 20'WIDE X 30'LONG X 10'HIGH EXTENSION ADDED TO EXISTING PREMISE W...
2008
2006
2000
The most recent 6 events from each dataset, so no one source takes the axis. Each tab holds the full record.
Property Contacts
Contact information aggregated from multiple government sources
Registration Contracts
Contact information from multiple dwelling registrations
Building Permits
Owner information from Department of Buildings filings
Recent Building Permits
Owner information from recent DOB NOW filings
Deed Records
Parties from ACRIS deed and mortgage records
Property Records
Owner information from assessment and PLUTO records