2294-2298 Nostrand Avenue, Brooklyn
Brooklyn • Block 07593 • Lot 0051 • Zip: 11210
Condition
What the city currently has open against this building, counted from its own records.
Address
Land use and zoning
Building
Latest assessment
Neighborhood
The area this lot falls inside, and the commute Hoodkit measures from it.
Getting around
Estimated about 8 hours ago- Downtown Brooklyn 35 min 6 walking, 29 riding
- Union Square 39 min 6 walking, 33 riding
- Times Square 43 min 6 walking, 37 riding
- Fulton Street 43 min 6 walking, 37 riding
- Grand Central 49 min 6 walking, 43 riding
- Penn Station 50 min 6 walking, 44 riding
Around this address
Transit and places within 0.5 miles of the lot.
Getting out
Subway
Bus
Activity
Sales, filings, permits and violations from every dataset, in one order.
2025
2024
-
Alteration Type I
2023
-
CLASS - 2
PROVIDE KEYS AND PERTINENT INFO INDICATING LOCATION OF THIS DEVICE IN ORDER TO PERFORM A FULL INSPECTION OF THIS DEVICE
2022
2021
-
Alteration Type II
PROPOSED DIALYSIS CENTER ON FIRST FLOOR INCLUDING NEW PARTITIONS,DOORS, CEILINGS, FLOORING AND FINISHES
-
DOB violation Apr 29, 2021
EGRADE-FAILURE TO POST ENERGY GRADE/SCORE NONE
FAILURE TO DISPLAY ENERGY EFFICIENCY SCORE AND ENERGY EFFICIENCY GRADE AS PER ADCODE SEC. 28-309.12.3
-
DOB violation Feb 2, 2021
BENCH-FAILURE TO BENCHMARK NONE
FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
2020
-
DOB violation Nov 2, 2020
BENCH-FAILURE TO BENCHMARK NONE
FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
-
DOB violation Aug 2, 2020
BENCH-FAILURE TO BENCHMARK NONE
FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
-
DOB violation May 2, 2020
BENCH-FAILURE TO BENCHMARK NONE
FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
2019
-
Alteration Type II
ADDITIONS/MODIFICATIONS TO EXISTING FIRE ALARM SYSTEM.
-
Alteration Type II
INSTALLATION OF MANUAL, AUTOMATIC SMOKE/HEAT/C.O. DETECTION & SPRINKLER FIRE ALARM SYSTEM FOR COMMERCIAL TENANTS ...
2018
2016
-
Alteration Type I
COMBINE OFFICES AND RETAIL STORES AT 1ST FLOOR INTO NEW STORE. NEW STORE FRONT , ROOF AND PARAPET REPAIR, STUCTURAL F...
-
Alteration Type II
SYSTEM SHALL BE A MANUAL AND AUTOMATIC SMOKE DETECTION AND SPRINKLER FIRE ALAR M SYSTEM
-
CLASS - 2
WORK DOES NOT CONFORM TO APPROVED CONSTRUCTION DOCUMENTS &/OR APPROVEDAMENDMENTS. SIGN JOB #320764516 12-13-13 ON AN ...
2015
-
CLASS - 2
ELECTRICAL WORK W/O PERMIT. OBSERVED @ 12PM SERVICE SWITCHES INSTALLEDIN BASEMENT 400AMPS,100AMPS ALONG W/SERVICE ENT...
2010
-
CLASS - 2
WORK CONTRARY TO PLAN APPL. #320209573 SHOWS REPLACEMENT OF BRICK TO CMU 5' FROM TOP & REMOVAL OF STEEL LINTEL,NOW NO...
-
CLASS - 1
FAILURE TO MAINTAIN EXTERIOR BLDG WALL(NORTHSIDE)NOTED:BULGING WALL @ REAR OF 29-18 AVE I WITH MISSING MORTAR.REM:MAK...
2003
1999
-
DOB violation Jun 30, 1999
C-CONSTRUCTION OTHER OPTIONAL
WORK WITHOUT A PERMIT. WORK NOTED: ERECT WOODEN SCAFFOLD AT FRONT OF STORES TO STRIP FRONT OF PREMISES. 50FT LONG X 1...
The most recent 6 events from each dataset, so no one source takes the axis. Each tab holds the full record.
Property Contacts
Contact information aggregated from multiple government sources
Building Permits
Owner information from Department of Buildings filings
Recent Building Permits
Owner information from recent DOB NOW filings
Deed Records
Parties from ACRIS deed and mortgage records
Property Records
Owner information from assessment and PLUTO records