2390 Nostrand Avenue, Brooklyn
Brooklyn • Block 07611 • Lot 0051 • Zip: 11210
Condition
What the city currently has open against this building, counted from its own records.
Address
Land use and zoning
Building
Latest assessment
Neighborhood
The area this lot falls inside, and the commute Hoodkit measures from it.
Getting around
Estimated 5 days ago- Downtown Brooklyn 35 min 6 walking, 29 riding
- Union Square 39 min 6 walking, 33 riding
- Times Square 43 min 6 walking, 37 riding
- Fulton Street 43 min 6 walking, 37 riding
- Grand Central 49 min 6 walking, 43 riding
- Penn Station 50 min 6 walking, 44 riding
Around this address
Transit and places within 0.5 miles of the lot.
Getting out
Bus
Activity
Sales, filings, permits and violations from every dataset, in one order.
2023
-
DOB violation Jun 20, 2023
HBLVIO-HIGH PRESSURE BOILER BOILER REQUIRED
VIOLATION ISSUED-FAILURE TO FILE 2018 INTERNAL HGH PRESSURE INSPECTION
2009
-
CLASS - 2
18A, 38, 50. 18A-TOP LEFT HAND HOLE CORRODED. 50-DRAFT INDUCER NOT INTERLOCKED W/BURNE. 38-(NOT ENOUGH FRESH AIR FOR ...
-
Alteration Type II
INTERIOR RENOVATION AND EXTENSION OF EXISTING 1ST FLOOR.INSTALL NEW PLUMBING FIXTURES AND MINOR GYP.BD.WORK. NO CHANG...
2008
-
Non-Hazardous
50A,B.FULTON VT BOILER,10HP,NB 76443,OIL,1996.50A-CORRODED SECTION OF FEED WATER INLET LINE NEAR BOILER SHELL.REPLACE...
2006
-
Non-Hazardous
50.FULTON V.T.BOILER,10HP,NB76443,OIL,1996.50-IMPROPER ARRANGEMENT OF THE BLOWDOWN VALVES.INSTALL A SCREW-TYPE(SLOW)V...
2004
2000
-
Non-Hazardous
49 1.DOCUMENTATION FOR THE BOILER IE 900A TERM AND SCHEDULE "C" IS INCORRECT FOR THIS HIGH PRESSURE BOILER-2 WORK PER...
1997
1994
-
DOB violation Jun 1, 1994
LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED
1993
-
DOB violation Aug 16, 1993
LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED
-
DOB violation Jun 1, 1993
LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED
1992
-
Non-Hazardous
ALTERED BUILDING OCCUPIED WITHOUT A VALID CERTIFICATE OF OCCUPANCY.ALTERATION #1134/70.REMEDY:OBTAIN C OF O.
-
Non-Hazardous
FAILURE TO PROVIDE APPROVED PLANS AT PREMISES AT TIME OF INSPECTION.REMEDY:PROVIDE APPROVED PLANS.
The most recent 6 events from each dataset, so no one source takes the axis. Each tab holds the full record.
Property Contacts
Contact information aggregated from multiple government sources
Building Permits
Owner information from Department of Buildings filings
Deed Records
Parties from ACRIS deed and mortgage records
Property Records
Owner information from assessment and PLUTO records