| Issued | Class | Status | Violation | Apartment | Correct by |
|---|---|---|---|---|---|
| Jun 10, 2025 | A | VIOLATION DISMISSED | (A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION ... | — | Sep 13, 2025 |
| Mar 1, 2022 | A | VIOLATION DISMISSED | (A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION ... | — | Jun 4, 2022 |
| Apr 12, 2021 | A | VIOLATION DISMISSED | (A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION ... | — | Jul 16, 2021 |
| Aug 6, 2019 | C | VIOLATION CLOSED | § 27-2005, 2007 ADM CODE ARRANGE AND MAKE SELF-CLOSING THE DOORS .. IN THE ENTRANCE LOCATED AT APT 2F, 2nd STORY, 1st... | 2F | Aug 27, 2019 |
| Jun 21, 2019 | C | VIOLATION CLOSED | § 27-2005, 2007 ADM CODE ARRANGE AND MAKE SELF-CLOSING THE DOORS AT FRONT ENTRANCE LOCATED AT APT 2F, 2nd STORY, 2nd ... | 2F | Jul 12, 2019 |
| — | I | VIOLATION DISMISSED | §27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE §27... | — | — |
| May 8, 2018 | A | NOT COMPLIED WITH | § 300 M/D LAW FILE PLANS AND APPLICATION AND LEGALIZE THE FOLLOWING ALTERATION OR RESTORE TO THE LEGAL CONDITION EXIS... | 2F | Aug 11, 2018 |
| May 8, 2018 | B | VIOLATION CLOSED | § 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT SINK IN THE KITCHEN LOCATED AT APT 2F, 2nd STORY, APA... | 2F | Jun 12, 2018 |
| May 8, 2018 | B | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE HEAVY DUTY LOCKSET IN THE BUILDING ENTRANCE STREET TO VEST... | — | Jun 12, 2018 |
| May 8, 2018 | B | VIOLATION CLOSED | § 27-2005, 2007 ADM CODE ARRANGE AND MAKE SELF-CLOSING THE DOORS IN THE BUILDING ENTRANCE STREET TO VESTIBULE AT PUBL... | — | Jun 12, 2018 |
| May 8, 2018 | B | VIOLATION CLOSED | § 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT SHOWER STALL AT BATHROOM, 2nd STORY, APARTMENT | 2F | Jun 12, 2018 |
| May 8, 2018 | B | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE GLASS SLIDING SHOWER DOOR AT BATHROOM, 2nd STORY, APARTMENT | 2F | Jun 12, 2018 |
| May 8, 2018 | B | NOT COMPLIED WITH | § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE VENTILATOR AT CEILING AT BATHROOM, 2nd STORY, APARTMENT | 2F | Jun 12, 2018 |
| May 8, 2018 | A | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE BASEBOARD RADIATOR AT WEST WALL AT BATHROOM, 2nd STORY, AP... | 2F | Aug 11, 2018 |
| May 8, 2018 | B | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE GROUT AT CERAMIC TILES IN THE SHOWER... | 2F | Jun 12, 2018 |
| May 8, 2018 | B | NOT COMPLIED WITH | § 27-2005, 2007 ADM CODE ARRANGE AND MAKE SELF-CLOSING THE DOORS .. IN THE ENTRANCE LOCATED AT APT 2F, 2nd STORY, APA... | 2F | Jun 12, 2018 |
| May 8, 2018 | A | NOT COMPLIED WITH | § 300 M/D LAW FILE PLANS AND APPLICATION AND LEGALIZE THE FOLLOWING ALTERATION OR RESTORE TO THE LEGAL CONDITION EXIS... | 2F | Aug 11, 2018 |
| May 8, 2018 | A | NOT COMPLIED WITH | § 300 M/D LAW FILE PLANS AND APPLICATION AND LEGALIZE THE FOLLOWING ALTERATION OR RESTORE TO THE LEGAL CONDITION EXIS... | 2F | Aug 11, 2018 |
| May 8, 2018 | A | VIOLATION CLOSED | § 27-2005 ADM CODE REFIT ALL WINDOWS UPPER AND LOWER SASHES IN THE ENTIRE APARTMENT LOCATED AT APT 2F, 2nd STORY, APA... | 2F | Aug 11, 2018 |
| May 8, 2018 | C | VIOLATION CLOSED | § 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) IN ACCORDANCE WITH THE SPECIFICAT... | 2F | Jun 5, 2018 |
| May 7, 2018 | A | NOT COMPLIED WITH | § 300 M/D LAW FILE PLANS AND APPLICATION AND LEGALIZE THE FOLLOWING ALTERATION OR RESTORE TO THE LEGAL CONDITION EXIS... | 2F | Aug 10, 2018 |
| May 7, 2018 | A | VIOLATION CLOSED | § 27-2104 ADM CODE POST AND MAINTAIN A PROPER SIGN ON WALL OF ENTRANCE STORY SHOWING THE REGISTRATION NUMBER ASSIGNED... | — | Aug 10, 2018 |
| May 7, 2018 | A | VIOLATION CLOSED | § 27-2046.1 HMC: POST A PROPER NOTICE OF CARBON MONOXIDE DETECTING DEVICE REQUIREMENTS, IN A FORM APPROVED BY THE COM... | — | Aug 10, 2018 |
| May 7, 2018 | A | VIOLATION CLOSED | § 27-2005 HMC: POST, IN A FORM APPROVED BY THE COMMISSIONER, AND MAINTAIN A NOTICE IN A COMMON AREA OF THE BUILDING R... | — | Aug 10, 2018 |
| May 7, 2018 | A | VIOLATION CLOSED | § 26-1103 ADMIN. CODE: POST AND MAINTAIN A PROPER NOTICE ON WALL OF THE ENTRANCE STORY IN ENGLISH AND SPANISH ON THE ... | — | Aug 10, 2018 |
| May 7, 2018 | B | NOT COMPLIED WITH | § 27-2005, 2007 ADM CODE ARRANGE AND MAKE SELF-CLOSING THE DOORS ... IN THE ENTRANCE LOCATED AT APT 2F, 2nd STORY, 1s... | 2F | Jun 11, 2018 |
| May 7, 2018 | C | VIOLATION CLOSED | § 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) IN ACCORDANCE WITH THE SPECIFICAT... | 2F | Jun 4, 2018 |
| May 7, 2018 | B | VIOLATION CLOSED | § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). INOPERATIVE IN THE ENTIRE APARTMENT LOCAT... | 2F | Jun 11, 2018 |
| May 7, 2018 | B | VIOLATION CLOSED | § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR INOPERATIVE IN THE ENTIRE APARTMENT LOCATED AT APT 2F, 2nd ST... | 2F | Jun 11, 2018 |
| May 7, 2018 | A | NOT COMPLIED WITH | § 300 M/D LAW FILE PLANS AND APPLICATION AND LEGALIZE THE FOLLOWING ALTERATION OR RESTORE TO THE LEGAL CONDITION EXIS... | 2F | Aug 10, 2018 |
| May 7, 2018 | A | NOT COMPLIED WITH | § 300 M/D LAW FILE PLANS AND APPLICATION AND LEGALIZE THE FOLLOWING ALTERATION OR RESTORE TO THE LEGAL CONDITION EXIS... | 2F | Aug 10, 2018 |
| May 7, 2018 | A | NOT COMPLIED WITH | § 300 M/D LAW FILE PLANS AND APPLICATION AND LEGALIZE THE FOLLOWING ALTERATION OR RESTORE TO THE LEGAL CONDITION EXIS... | 2F | Aug 10, 2018 |
| May 7, 2018 | A | NOT COMPLIED WITH | § 300 M/D LAW FILE PLANS AND APPLICATION AND LEGALIZE THE FOLLOWING ALTERATION OR RESTORE TO THE LEGAL CONDITION EXIS... | 2F | Aug 10, 2018 |
| May 7, 2018 | A | VIOLATION CLOSED | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT ALL PEELING PAINT SURFACES I... | 2F | Aug 10, 2018 |
| — | I | VIOLATION DISMISSED | §27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE §27... | — | — |
| Aug 4, 2016 | C | VIOLATION CLOSED | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT THE CEILING AND EAST WALL I... | 2R | Aug 12, 2016 |
| Aug 4, 2016 | C | VIOLATION CLOSED | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING APPROX.... | 2R | Aug 12, 2016 |
| Aug 2, 2016 | B | VIOLATION CLOSED | § 27-2005, 2007 ADM CODE FIRE EGRESS DEFECTIVE. REMOVE OBSTRUCTING BARS OR UNLAWFUL GATES FROM WINDOW TO FIRE ESCAPE ... | 2R | Sep 6, 2016 |
| Aug 2, 2016 | B | VIOLATION CLOSED | § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING LOCATED AT APT 2R, 2nd STORY, APARTMENT AT EAST | 2R | Sep 6, 2016 |
| Aug 2, 2016 | B | VIOLATION CLOSED | § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING LOCATED AT APT 2R, 2nd STORY, APA... | 2R | Sep 6, 2016 |
| Aug 2, 2016 | A | VIOLATION CLOSED | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT ALL WALLS IN THE ENTIRE APAR... | 2R | Nov 5, 2016 |
| Aug 2, 2016 | B | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE VINYL FLOOR TILES IN THE 1st ROOM FR... | 2R | Sep 6, 2016 |
| Aug 2, 2016 | B | VIOLATION CLOSED | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK OVER THE WINDOW HEADER IN THE ... | 2R | Sep 6, 2016 |
| Aug 2, 2016 | B | VIOLATION CLOSED | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE WALLS AROUND TH... | 2R | Sep 6, 2016 |
| Aug 2, 2016 | A | VIOLATION CLOSED | § 300 M/D LAW FILE PLANS AND APPLICATION AND LEGALIZE THE FOLLOWING ALTERATION OR RESTORE TO THE LEGAL CONDITION EXIS... | 2R | Nov 5, 2016 |
| Aug 2, 2016 | B | VIOLATION CLOSED | § 27-2005, 2006, 2037 HMC: PROPERLY REPAIR AND ABATE UNSAFE ELECTRIC WIRING CONDITION CONSISTING OF EXPOSED ELECTRIC ... | 2R | Sep 6, 2016 |
| Aug 2, 2016 | A | VIOLATION CLOSED | § 300 M/D LAW FILE PLANS AND APPLICATION AND LEGALIZE THE FOLLOWING ALTERATION OR RESTORE TO THE LEGAL CONDITION EXIS... | 2R | Nov 5, 2016 |
| Aug 2, 2016 | A | VIOLATION CLOSED | § 300 M/D LAW FILE PLANS AND APPLICATION AND LEGALIZE THE FOLLOWING ALTERATION OR RESTORE TO THE LEGAL CONDITION EXIS... | 2R | Nov 5, 2016 |
| Jun 6, 2016 | A | VIOLATION CLOSED | § 27-2046.1 HMC: POST A PROPER NOTICE OF CARBON MONOXIDE DETECTING DEVICE REQUIREMENTS, IN A FORM APPROVED BY THE COM... | — | Sep 9, 2016 |
| Jun 6, 2016 | A | VIOLATION CLOSED | § 26-1103 ADMIN. CODE: POST AND MAINTAIN A PROPER NOTICE ON WALL OF THE ENTRANCE STORY IN ENGLISH AND SPANISH ON THE ... | — | Sep 9, 2016 |