Maintenance code violations
538 East 99 Street, Brooklyn • Block 08148 • Lot 0046
253 records
HPD grades a violation A for non-hazardous through C for immediately hazardous.
| Issued | Class | Status | Violation | Apartment | Correct by |
|---|---|---|---|---|---|
| Mar 20, 2026 | B | NOV SENT OUT | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE ELECTRIC OUTLET AT SOUTH WALL IN THE PRIVATE HALLWA... | 2 | Apr 24, 2026 |
| Mar 20, 2026 | B | NOV SENT OUT | § 27-2005 ADMIN. CODE: REPAIR THE ROOF SO THAT IT WILL NOT LEAK OVER CEILING IN THE 5th ROOM FROM EAST LOCATED AT APT... | 2 | Apr 24, 2026 |
| Mar 20, 2026 | B | VIOLATION WILL BE REINSPECTED | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... GREATER THAN 10 SQ.FT AT CEILING... | 2 | Apr 24, 2026 |
| Mar 20, 2026 | B | NOV SENT OUT | § 27-2005 ADMIN. CODE: REPAIR THE ROOF SO THAT IT WILL NOT LEAK OVER CEILING IN THE BATHROOM LOCATED AT APT 2, 2nd ST... | 2 | Apr 24, 2026 |
| Mar 20, 2026 | C | NOV SENT OUT | § 27-2073 ADM CODE - PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES RANGE IN THE KITCHEN LOCATED AT APT 2, 2nd STO... | 2 | Mar 26, 2026 |
| Mar 11, 2026 | B | NOV SENT OUT | § 27-2005 ADMIN. CODE: PROPERLY SECURE THE LOOSE HAND RAIL AT THE NORTH WALL AT THE STAIR FROM 1ST STORY LEADING TO 2... | 2 | Apr 15, 2026 |
| Mar 11, 2026 | B | NOV SENT OUT | § 27-2005 ADMIN. CODE: REPAIR THE ROOF SO THAT IT WILL NOT LEAK OVER THE CEILING IN THE 5th ROOM FROM EAST LOCATED AT... | 2 | Apr 15, 2026 |
| Mar 11, 2026 | A | NOV SENT OUT | § 27-2013 ADMIN. CODE: PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE EAST WALL AND CEILIN... | 2 | Jun 14, 2026 |
| Mar 11, 2026 | A | VIOLATION CLOSED | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10 SQ FT AT THE EAST W... | 2 | Jun 14, 2026 |
| Mar 11, 2026 | A | NOV SENT OUT | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE ELECTRICAL OUTLET AT THE NORTH WALL IN THE 5th ROOM... | 2 | Jun 14, 2026 |
| Mar 11, 2026 | B | NOV SENT OUT | § 27-2005 ADMIN. CODE: REPAIR THE ROOF SO THAT IT WILL NOT LEAK OVER THE CEILING IN THE BATHROOM LOCATED AT APT 2, 2n... | 2 | Apr 15, 2026 |
| Mar 11, 2026 | A | NOV SENT OUT | § 27-2013 ADMIN. CODE: PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE CEILING IN THE BATHR... | 2 | Jun 14, 2026 |
| Mar 11, 2026 | A | VIOLATION CLOSED | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10 SQ FT AT THE CEILIN... | 2 | Jun 14, 2026 |
| Mar 11, 2026 | C | NOV SENT OUT | § 27-2026 ADMIN. CODE: REPAIR THE FLUSHING APPARATUS AND MAINTAIN SAME SO AS TO FLUSH EFFECTIVELY THE WATER CLOSET IN... | 2 | Mar 17, 2026 |
| Mar 11, 2026 | A | VIOLATION CLOSED | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10 SQ FT AT THE EAST W... | 2 | Jun 14, 2026 |
| Mar 11, 2026 | B | NOV SENT OUT | § 27-2005 ADMIN. CODE: REPAIR THE ROOF SO THAT IT WILL NOT LEAK OVER THE CEILING IN THE KITCHEN LOCATED AT APT 2, 2nd... | 2 | Apr 15, 2026 |
| Mar 11, 2026 | A | NOV SENT OUT | § 27-2013 ADMIN. CODE: PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE EAST WALL AND CEILIN... | 2 | Jun 14, 2026 |
| Mar 11, 2026 | B | NOV SENT OUT | § 27-2024 ADMIN. CODE: PROVIDE ADEQUATE SUPPLY OF COLD WATER FOR THE FIXTURES AT SINK IN THE KITCHEN LOCATED AT APT 2... | 2 | Apr 15, 2026 |
| Mar 11, 2026 | B | NOV SENT OUT | § 27-2024 ADMIN. CODE: PROVIDE ADEQUATE SUPPLY OF HOT WATER FOR THE FIXTURES AT SINK IN THE KITCHEN LOCATED AT APT 2,... | 2 | Apr 15, 2026 |
| Mar 11, 2026 | B | NOV SENT OUT | § 27-2005, 2006, 2037 HMC: PROPERLY REPAIR AND ABATE UNSAFE ELECTRIC WIRING CONDITION CONSISTING OF EXPOSED ELECTRICA... | 2 | Apr 15, 2026 |
| Mar 11, 2026 | B | NOV SENT OUT | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE MECHANICAL VENTILATION SYSTEM AT THE CEILING IN THE... | 2 | Apr 15, 2026 |
| Mar 11, 2026 | B | NOV SENT OUT | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 2, 2nd STOR... | 2 | Apr 15, 2026 |
| Mar 4, 2026 | B | NOV SENT OUT | § 27-2005, 2006, 2037 HMC: PROPERLY REPAIR AND ABATE UNSAFE ELECTRIC WIRING CONDITION CONSISTING OF EXPOSED ELECTRIC ... | 2 | Apr 8, 2026 |
| Mar 4, 2026 | C | NOTICE OF ISSUANCE SENT TO TENANT | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 2, 2nd STOR... | 2 | Mar 30, 2026 |
| Mar 4, 2026 | B | NOV SENT OUT | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 2, 2nd S... | 2 | Apr 8, 2026 |
| Mar 4, 2026 | B | NOV SENT OUT | § 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON ... | 2 | Apr 8, 2026 |
| Mar 4, 2026 | B | NOV SENT OUT | § 27-2005 ADMIN. CODE: REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN UNIFORM COLOR AT CEILING IN THE... | 2 | Apr 8, 2026 |
| Mar 4, 2026 | A | VIOLATION CLOSED | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10 SQFT AT CEILING IN ... | 2 | Jun 7, 2026 |
| Mar 4, 2026 | B | NOV SENT OUT | § 27-2005 ADMIN. CODE: REPAIR THE ROOF SO THAT IT WILL NOT LEAK OVER CEILING IN THE 1st ROOM FROM EAST LOCATED AT APT... | 2 | Apr 8, 2026 |
| Mar 4, 2026 | B | NOV SENT OUT | § 27-2005 ADMIN. CODE: PROPERLY SECURE THE LOOSE HANDRAIL AT NORTH WALL IN THE FOYER LOCATED AT APT 2, 2nd STORY, 2nd... | 2 | Apr 8, 2026 |
| Mar 4, 2026 | A | VIOLATION CLOSED | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10 SQFT AT 1ST WINDOW ... | 2 | Jun 7, 2026 |
| Mar 4, 2026 | A | VIOLATION CLOSED | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10 SQFT AT CEILING AND... | 2 | Jun 7, 2026 |
| Mar 4, 2026 | B | NOV SENT OUT | § 27-2005 ADMIN. CODE: REPAIR THE ROOF SO THAT IT WILL NOT LEAK OVER CEILING IN THE KITCHEN LOCATED AT APT 2, 2nd STO... | 2 | Apr 8, 2026 |
| Mar 4, 2026 | B | NOV SENT OUT | § 27-2005, 2006, 2037 HMC: PROPERLY REPAIR AND ABATE UNSAFE ELECTRIC WIRING CONDITION CONSISTING OF EXPOSED ELECTRIC ... | 2 | Apr 8, 2026 |
| Mar 4, 2026 | B | NOV SENT OUT | § 27-2005 ADMIN. CODE: PROPERLY SECURE THE LOOSE ELECTRICAL OUTLET COVER AT SOUTH WALL IN THE PRIVATE HALLWAY LOCATED... | 2 | Apr 8, 2026 |
| Mar 4, 2026 | B | NOV SENT OUT | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE MECHANICAL VENTILATION SYSTEM AT CEILING IN THE BAT... | 2 | Apr 8, 2026 |
| Mar 4, 2026 | A | NOV SENT OUT | § 27-2005 ADMIN. CODE: REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN UNIFORM COLOR AT CEILING IN THE... | 2 | Jun 7, 2026 |
| Mar 3, 2026 | C | VIOLATION DISMISSED | § 27-2031 ADMIN. CODE: PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 2, 2nd STOR... | 2 | Mar 3, 2026 |
| Jan 22, 2026 | B | NOV SENT OUT | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE ELECTRICAL OUTLET COVER AT SOUTH WALL IN THE PRIVAT... | 2 | Feb 26, 2026 |
| Jan 22, 2026 | B | NOV SENT OUT | § 27-2005 ADMIN. CODE: REPAIR THE ROOF SO THAT IT WILL NOT LEAK OVER CEILING IN THE KITCHEN LOCATED AT APT 2, 2nd STO... | 2 | Feb 26, 2026 |
| Jan 22, 2026 | B | NOV SENT OUT | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 2, 2nd S... | 2 | Feb 26, 2026 |
| Jan 22, 2026 | B | NOV SENT OUT | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 2, 2nd STOR... | 2 | Feb 26, 2026 |
| Jan 22, 2026 | C | VIOLATION CLOSED | § 27-2024 ADMIN. CODE: PROVIDE ADEQUATE SUPPLY OF HOT WATER FOR THE FIXTURES AT ALL HOT WATER FIXTURES IN THE ENTIRE ... | 2 | Jan 28, 2026 |
| Jan 22, 2026 | C | NOV SENT OUT | § 27-2024 ADMIN. CODE: PROVIDE ADEQUATE SUPPLY OF COLD WATER FOR THE FIXTURES AT ALL COLD WATER FIXTURES IN THE ENTIR... | 2 | Jan 28, 2026 |
| Jan 22, 2026 | B | NOV SENT OUT | § 27-2005 ADMIN. CODE: PROPERLY SECURE THE LOOSE HANDRAIL AT NORTH WALL AT STAIRS BETWEEN 1ST STORY AND 2ND STORY IN ... | 2 | Feb 26, 2026 |
| Jan 22, 2026 | B | NOV SENT OUT | § 27-2005, 2006, 2037 HMC: PROPERLY REPAIR AND ABATE UNSAFE ELECTRIC WIRING CONDITION CONSISTING OF EXPOSED ELECTRICA... | 2 | Feb 26, 2026 |
| Jan 22, 2026 | B | NOV SENT OUT | § 27-2005 ADMIN. CODE: REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN UNIFORM COLOR THE CEILING IN TH... | 2 | Feb 26, 2026 |
| Jan 22, 2026 | B | NOV SENT OUT | § 27-2005 ADMIN. CODE: REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN UNIFORM COLOR THE CEILING IN TH... | 2 | Feb 26, 2026 |
| Jan 20, 2026 | A | VIOLATION CLOSED | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10 SQ FT AT EAST WALL ... | 2 | Apr 25, 2026 |
| Jan 20, 2026 | A | NOV SENT OUT | § 27-2013 ADMIN. CODE: PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT ALL PEELING PAINT SURFAC... | 2 | Apr 25, 2026 |