Skip to content

ECB violations

Uncommon Canarsie Elem School, Brooklyn • Block 08227 • Lot 0001

67 records

Environmental Control Board violations, which carry a hearing and a penalty.

Issued Violation Status Severity Description Penalty Balance due Hearing
Feb 23, 2023 35671627Z RESOLVE CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER.ILLUMINATION FOREXITS,EXIT DISCHARGES AND PUBLIC CORRIDORS PER ... $625 $0 Jun 7, 2023
Mar 29, 2022 35578413R RESOLVE CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER.ILLUMINATION FOREXITS,EXIT DISCHARGES AND PUBLIC CORRIDORS PER ... $625 $0 Sep 21, 2022
Aug 28, 2020 35495996Y RESOLVE CLASS - 2 FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER. NOTED: AT THE ROOF LEVEL THE CHIMNEY HAS RUNNING STEP CRACKS IN VA... $625 $0 Jan 13, 2021
Mar 16, 2020 35490605P RESOLVE CLASS - 2 EXIT DOOR NOT SELF CLOSING. AT THE TIME OF INSPECTION I OBSERVED AT EXIT#5(2)DOORS ARE NOT CLOSING. REISSUED#35383749... $1,562 $0 Sep 9, 2020
Mar 13, 2019 35383749K RESOLVE CLASS - 2 EXIT DOOR NOT SELF CLOSING OBSERVE AT EXIT #5 RIGHT AND LEFT DOOR NOT SELF CLOSING REPAIR OR REPLACE DOOR $0 $0 Sep 23, 2019
Mar 13, 2019 35383748Z RESOLVE CLASS - 2 FIALURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER:NO FIRE STOPPING PER BC 712.3:27-345 OBSERVED IM SEVERAL ROOMS ... $1,250 $0 Sep 23, 2019
Feb 27, 2018 35316740Y RESOLVE CLASS - 2 SEC. 28-301.1 UNLAWFUL DISPLAY OF ARTWORK IN CORRIDORS GREATER THAN 20% PER FDNY 2008 CODE FC803.3.2. NOTED: ARTWORK ... $0 $0 May 7, 2018
Feb 27, 2018 35316741X RESOLVE CLASS - 2 REISSUE#35235765X FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER. NOTED: AT GYM AREA @ 1ST FL,4 MISSING CEILING TI... $0 $0 May 7, 2018
Mar 31, 2017 35235765X RESOLVE CLASS - 2 FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER. NOTED: @ 1ST FL GYMAREA,MISSING CEILING TILES DUE TO WATER PENETRA... $0 $0 May 15, 2017
Jun 28, 2016 35195440Y RESOLVE CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER: LACK OF EMERGENCY LIGHTING FOR EXITS, EXIT DISCHARGES AND PUBL... $0 $0 Sep 12, 2016
Jun 28, 2016 35195439R RESOLVE CLASS - 2 EXIT DOOR NOT SELF CLOSING. NOTED: AT 3RD FLOOR ROOM #325, 2ND FLOOR ROOM 219, 1ST FLR ROOM 115 AND 105 AND 101, 1ST ... $0 $0 Sep 12, 2016
Jun 28, 2016 35195442H ACTIVE CLASS - 2 OPERATION OF A PLACE OF ASSEMBLY W/O A CURRENT CERTIFICATE OF OPERATION. NOTED: AT 1ST FLR, AUDITORIUM AREA, THE PLAC... $0 $0 Sep 12, 2016
Jun 28, 2016 35195441X ACTIVE CLASS - 2 OPERATION OF A PLACE OF ASSEMBLY W/O A CURRENT CERTIFICATE OF OPERATION. NOTED: AT 1ST FLOOR, GYM AREA, THE PLACE OF ... $0 $0 Sep 12, 2016
Jun 28, 2016 35195443J ACTIVE CLASS - 2 OPERATION OF A PLACE OF ASSEMBLY W/O A CURRENT CERTIFICATE OF OPERATION. NOTED: AT BASEMENT, CAFETERIA AREA, THE PLAC... $0 $0 Sep 12, 2016
Jul 24, 2014 35101362H RESOLVE CLASS - 2 REISSUE 335018463J DOORS RACKED AT STAIR D 1ST FLR AND STAIR "G" EXITDOOR AT BASEMENT HAS BROKEN. RMDY: REPAIR OR REP... $0 $0 Sep 29, 2014
May 23, 2013 35018463J RESOLVE CLASS - 2 DOORS RACKED AT STAIR D 1ST & 2ND FLRS & CORRIDOR DOOR ADJACENT TO RM 207 HAS BROKEN CLOSER. RMDY: REPAIR OR REPLACE ... $2,500 $0 Jul 15, 2013
May 23, 2013 35019573P RESOLVE CLASS - 2 27-371(B) PLEXI VISION PANELS INSTALLED ON DOORS TO ROOMS 313,331,307,301,206,200 GIRLS & BOYS GYMS AND ON DOORS TO S... $0 $0 Jul 15, 2013
Jan 31, 2012 34942334K RESOLVE CLASS - 2 WATER DAMAGED CEILINGS AT: 1ST STORY AUDITORIUM CONCEALED SPLINE CEILING WATER DAMAGED, 3RD STORY ROOMS 301,309,311 &... $0 $0 Apr 16, 2012
Jan 31, 2012 34942335M RESOLVE CLASS - 2 DOORS NOT CLOSING AT: ROOF 3 BULKHEAD DOORS RUSTED/DETERIORATED JAMBS & SADDLES, DOORS SPLIT/WATER DAMAGED, 3RD STORY... $0 $0 Apr 16, 2012
Jan 31, 2012 34942333Z RESOLVE CLASS - 2 REISSUE # 34930883P. ROOF LEAKS WATER PENETRATING ROOF ABOVE ROOMS 301,309,311,331 & STAIRS C & D. REMEDY: REPAIR AND... $0 $0 Apr 16, 2012
Oct 11, 2011 34930884R RESOLVE CLASS - 3 RE-ISSUED 34770828M. NOTED: SPALLING, CRACKING & SEPARATION OF CONCRETE SLAB RETAINING WALL @ THE THE E 100 ST SECTIO... $0 $0 Dec 5, 2011
Oct 11, 2011 34930883P RESOLVE CLASS - 2 FAILRUE TO MAINTAIN. NOTED : @ ROOMS 331, 311, 309, & 301 HAVE DAMAGESTO THEIR CEILINGS & WALLS DUE TO WATER PENETRAT... $0 $0 Dec 5, 2011
Jul 27, 2010 34871700X RESOLVE CLASS - 2 INTERIOR WALL IN THE ELECTRICAL ROOM IS CRACKED @ THE CELLAR LEVEL.REM: REPAIR AND/OR REPLACE CRACKS. $0 $0 Sep 13, 2010
Jul 27, 2010 34871701H RESOLVE CLASS - 2 THE BOILER BRICK BASE IS MISSING MORTAR & CRACKED LOCATED @ THE CELLAR LEVEL. REM:REPAIR AND/OR REPLACE BRICK BASE. $0 $0 Sep 13, 2010
Jul 27, 2010 34871702J RESOLVE CLASS - 2 EXTERIOR FOUNDATION WALL IS LEAKING WATER CAUSING INTERIOR DAMAGES IN THE GAS METER ROOM @ THE CELLAR LEVEL. REM:WATE... $0 $0 Sep 13, 2010
Jun 16, 2009 34770829Y RESOLVE CLASS - 3 NOTE:PARTIAL OBSTRUCTION DUE TO STORAGE OF TABLES AND TV SET LOCATION AUDITORIUM EXIT VESTIBULE AT LEFT SIDE OF STAGE... $500 $0 Sep 14, 2009
Jun 16, 2009 34770827K RESOLVE CLASS - 3 FAILURE TO MAINTAIN NOTE:WATER LEAKING FROM PIPES AT CEILING LOCATION BSMT LEVEL IN CORRIDOR NEAR ELECTRICAL METER RM... $0 $0 Sep 14, 2009
Jun 16, 2009 34770825R RESOLVE CLASS - 3 REISSUE #34508834P FAILURE TO MAINTAIN NOTE: 1 GAS METER BEING USED FOR STORAGE OF BACK YD PAINT MOTOR OIL AND MISC S... $0 $0 Sep 14, 2009
Jun 16, 2009 34770826Z RESOLVE CLASS - 3 FAILURE TO MAINTAIN NOTE:VERTICAL CRACKS IN BRICK WORK LOCATION MAIN CHIMNEY 4 SIDES AT ROOF LEVEL REMEDY:MAINTAIN & ... $0 $0 Sep 14, 2009
Jun 16, 2009 34770828M RESOLVE CLASS - 3 FAILURE TO MAINTAIN NOTE:SPALLING,CRACKING AND SEPERATION OD CONCRETE AT SLAB AND RETAINING WALL LOCATION ON 100 ST F... $0 $0 Sep 14, 2009
Mar 5, 2008 34639643M RESOLVE Non-Hazardous FAILURE TO MAINTAIN - EXTERIOR. DEBRIS FROM COLLAPSED GREENHOUSE IS LAYING ON THE SCHOOL PROPERTY ALONG AVENUE J, SUP... $0 $0 Apr 21, 2008
Mar 5, 2008 34639642K RESOLVE Non-Hazardous FAILURE TO MAINTAIN - EXTERIOR - HAZARDOUS. CONCRETE STAIRS BY AVENUE J AND EAST 101 ST - BOTTOM STEP CONCRETE BROKEN... $0 $0 Apr 21, 2008
Feb 1, 2007 34560815H RESOLVE Non-Hazardous EXIT DOORS NOT SELF-CLOSING. FIRE/SMOKE DOORS THAT HAVE NO CLOSURES, BROKEN CLOSURES, 3RD FL EXIT 3 STAIR H 1 DOOR, C... $0 $0 Apr 16, 2007
Feb 1, 2007 34560814X RESOLVE Non-Hazardous FAILURE TO MAINTAIN BUILDING - INTERIOR. ROTTEN DOOR JAMB IN FRONT EXIT DOORS #7,#8,#9 CAUSING FIRE EXIT DOORS TO STA... $0 $0 Apr 16, 2007
Feb 1, 2007 34560816J RESOLVE Non-Hazardous RE-ISSUE:34508834P. FAILURE TO MAINTAIN. GAS METER ROOM/ELECTRIC ROOM,NOTED ROOMS ARE USED AS STORAGE ROOMS, PAINT CA... $0 $0 Apr 16, 2007
Mar 22, 2006 34508832L RESOLVE Hazardous ROTTEN DOOR JAMBS IN FRONT EXIT DOORS EXIT #7; #8; #1. REMEDY: REPAIR/REPLACE DOOR JAMBS. $0 $0 Jun 5, 2006
Mar 22, 2006 34508834P RESOLVE Hazardous FAILURE TO MAINTAIN GAS METER ROOM, ELECTRICAL ROOM FREE/CLEAR OF STOPAGE-PAINT CANS, EQUIPMENT, BAGS AS PER NYC BLDG... $0 $0 Jun 5, 2006
Mar 22, 2006 34508835R RESOLVE Hazardous WATER PENETRATION THROUGH ROOF IN GYM (OFFICE). REMEDY: REPAIR/ MAINTAIN ROOF. $0 $0 Jun 5, 2006
Mar 22, 2006 34508830H RESOLVE Hazardous REISSUE #34444548Y. MISSING EXIT DOORS: 1)3 FLR STAIR A (2 LEAFS) 2)1ST FLR STAIR "H". REMEDY: REPLACE MISSING DOORS. $0 $0 Jun 5, 2006
Mar 22, 2006 34508831J RESOLVE Hazardous VERTICAL CRACKS BY EXPANSIVE JOINT FROM 3 FLR DOWN TO BASEMENT (OPENING MORE 1/2"-3/4") REMEDY: REPAIR GLASED BLOCKS. $0 $0 Jun 5, 2006
Mar 22, 2006 34508833N RESOLVE Hazardous EXIT DOOR ON 2ND FLR BY STAIR A AND STAIR B NOT SELF-CLOSING. REMEDY: REPAIR/REPLACE DOORS/HARDWARE. $0 $0 Jun 5, 2006
Apr 28, 2005 34474949M RESOLVE Non-Hazardous REISSUE 34444548Y. MISSING FIRE SMOKE STOP DOORS IN CORRIDOR AT VARIOUS LOCATIONS 1ST FLR 1A & 2B AND 2ND FLR. 3C & 4... $0 $0 Aug 15, 2005
Jul 13, 2004 34444550N RESOLVE Non-Hazardous "REISSUE" (34387286P) FAILURE TO USE PANIC HARDWARE WHERE REQUIRED BY LAW.NOTE NO PANIC HARDWARE INSTALL ON AUDITORIU... $0 $0 Sep 20, 2004
Jul 13, 2004 34444502Z RESOLVE Non-Hazardous FAILURE TO MAINTAIN.DEFECT ARE MISSING BATHROOM STALL DOORS AND CORRODED PARTITIONS.LOCATIONS ARE (1)2ND FLOOR GIRLS ... $0 $0 Sep 20, 2004
Jul 13, 2004 34444501R RESOLVE Non-Hazardous FAILURE TO MAINTAIN.DEFECT IS MISSING AND LOOSE 12"X12" CEILING TILES IN 3RD FLOOR CORRIDOR.REMEDY:REPAIR CEILING $0 $0 Sep 20, 2004
Jul 13, 2004 34444503K RESOLVE Non-Hazardous FAILURE TO MAINTAIN.DEFECT IS STEEL FENCE BROKEN AND LOOSE AT NORTH SIDE OF BLDG.(AVE "J" STREET) REMEDY:REPAIR FENCE. $0 $0 Sep 20, 2004
Jul 13, 2004 34444548Y RESOLVE Non-Hazardous REISSUE.(34387287R) FAILURE TO MAINTAIN.DEFECTS ARE MISSING CORRIDOR DOORS AT VARIOUS LOCATIONS.LOCATIONS ARE (1) THI... $0 $0 Sep 20, 2004
Jul 13, 2004 34444549X RESOLVE Non-Hazardous "REISSUE" (34387288Z) FAILURE TO MAINTAIN DEFECTS ARE ROOF LEAKS IN ROOM #331 AND 305.REMEDY:REPAIR ROOF. $0 $0 Sep 20, 2004
Feb 20, 2003 34387286P RESOLVE Non-Hazardous FAILURE TO MAINTAIN NOTED MISSING PANIC HARDWARE LOCATION EXIT A AUDQTORIUM 1 DLOOR HARDWARE MISSING. REMEDY; REPAIR ... $0 $0 May 12, 2003
Feb 20, 2003 34387287R RESOLVE Non-Hazardous FAILURE TO MAINTAIN. NOTED MISSING DOORS LOCATION. STAIRWAY 1 & 2 1ST FLOOR CROSS CORRIDOR DOOR AT 1ST & 3RD FLOOR. R... $0 $0 May 12, 2003