ECB violations
1709-1729 Emmons Avenue, Brooklyn • Block 08771 • Lot 0129
27 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Feb 12, 2025 | 39138234H | ACTIVE | CLASS - 2 | WORK WITHOUT A PERMIT .AT TIME OF INSPECTION I OBSERVED AT FRONT FACADE AN EXTERIOR GLASS STRUCTURE APPROX.7FT X33FT ... | $1,250 | $0 | Apr 23, 2025 |
| Jun 21, 2022 | 39064474H | RESOLVE | CLASS - 2 | PROVIDE KEYS TO ROOF/GOVERNOR AND MACHINE ROOM/BASEMENT. CAR STOPS WHEN 1ST FLOOR DOOR PULLED. | $0 | $0 | Nov 23, 2022 |
| Jun 21, 2022 | 39064475J | RESOLVE | CLASS - 2 | SECURE CAR STATION. WATER IN PIT. PROVIDE KEYS TO ROOF/GOVERNOR AND MACHINE ROOM/BASEMENT. | $0 | $0 | Nov 23, 2022 |
| Apr 22, 2022 | 35578990R | ACTIVE | CLASS - 3 | WORK W/O PERMIT UPON INSP,OBSERVED APRX5WORKERS PERFORMING CONST ON EXP2 OF GRNDFL RESTAURANT,BLDG ENCLOSED AREA APRX... | $500 | $0 | Jan 20, 2023 |
| May 13, 2021 | 39041146R | RESOLVE | CLASS - 2 | REPAIR IN-CAR STOP SWITCH ALARM., PROVIDE KEYS TO ACCESS MOTOR ROOM, PROVIDE KEYS TO ACCESS PIT., PROVIDE KEYS TO ACC... | $0 | $0 | Oct 6, 2021 |
| May 13, 2021 | 39041147Z | RESOLVE | CLASS - 2 | REPAIR IN-CAR STOP SWITCH ALARM., PROVIDE KEYS TO ACCESS MOTOR ROOM, PROVIDE KEYS TO ACCESS PIT., PROVIDE KEYS TO ACC... | $0 | $0 | Oct 6, 2021 |
| Jul 31, 2020 | 35410657Y | RESOLVE | CLASS - 1 | FAILURE TO PROVIDE UNOBSTRUCTED EXIT PASSAGEWAY. AT TIME OF INSPECTIONFOUND: FIRE ESCAPE ALONG SHEEPHEAD BAY ROAD SID... | $1,250 | $0 | Feb 25, 2021 |
| May 26, 2020 | 39022735L | RESOLVE | CLASS - 2 | WATER IN PIT. SEAL HOIST MACHINE LEAKS. OIL ON MR FLOOR. UNTAGGED FIRE EXTINGUISHER | $0 | $0 | Sep 30, 2020 |
| May 26, 2020 | 39022734J | RESOLVE | CLASS - 1 | CEASE USE ITEM: INOPERATIVE ZONE LOCK RESTRICTOR CLASS 2 ITEMS: INAUDIBLE STOP SWICTH. MISSING CAB MIRROR. INOPERATIV... | $1,250 | $0 | Jun 7, 2021 |
| Nov 15, 2017 | 38259374Y | RESOLVE | CLASS - 2 | 40M07,57BB11,68M07,70Z09,70B01,76Q03,37H11,52Q03.(40M)VENTRGIAN PER K3.(68M)MISSING BRAKE MAINT DATE.(70B)PILE OF DEB... | $250 | $0 | Jan 8, 2018 |
| Nov 14, 2017 | 38259371Z | RESOLVE | CLASS - 1 | C/U 42X10,40M07,100M07,56Y13,40Y02,57T15,68B07,70Q03,70Z07,76Q03,56T15,27J10,27Q03,37J07,37H11.CEASE USE ITEM(42X)DOO... | $500 | $0 | Jan 8, 2018 |
| Mar 28, 2017 | 38253405K | RESOLVE | CLASS - 1 | CU-21J01,CU21L10; 29B10,68M07,11L10. CEASE USE-21J-ADJUST 1ST FLOOR DOOR LOCK TO PROPER ALIGNMENT WITH KEEPER; 21L-RE... | $1,000 | $0 | May 15, 2017 |
| Mar 28, 2017 | 38253406M | RESOLVE | CLASS - 2 | 32B01,67X10,68M07,29B01. 32B-ADJUST GUIDESHOES AND 29B-ADJUST DOOR OPERATOR TO PREVENT MOVEMENT OF ELEVATOR PLATFORM ... | $0 | $0 | May 15, 2017 |
| Nov 5, 2011 | 34970280M | RESOLVE | CLASS - 2 | FAILURE TO COMPLY W/THE COMM'S ORDER TO FILE A CERTIFICATE OF CORRECTION W/THE DOB FOR NOV#34913227M ISSUED ON 06/18/... | $400 | $0 | Mar 19, 2012 |
| Jun 18, 2011 | 34913227M | RESOLVE | CLASS - 1 | FAILURE TO PROVIDE UNOBSTRUCTED EXIT PASSAGEWAY IN THAT THERE ARE SEVERAL BICYCLES THAT ARE CHAINED TO THE HANDRAIL O... | $6,000 | $0 | Aug 8, 2011 |
| May 6, 2009 | 38203023J | RESOLVE | CLASS - 2 | 68M2.46M7.21J1.39M7.32H11.15M CERT. 56Y SEAL LEAKS 56D.Q GREENFIELD EXPOSED WIRES 42G.61 UNREADABLE OR WRONG RATED FU... | $0 | $0 | Jun 29, 2009 |
| May 6, 2009 | 38203022H | RESOLVE | CLASS - 2 | 15M7.42G11.61G11.11X10.45B9.29H11.32H11.15M PROVIDE CERT. 42.61G UNREADABLE FUSES 56Y SEAL LEAKS 56D GREENFIELD 8.69M... | $0 | $0 | Jun 29, 2009 |
| Jun 18, 2008 | 38185957R | RESOLVE | Non-Hazardous | SECOND OFFENSE 14X10 24-X BSMT HALL INDICATOR | $800 | $0 | May 13, 2010 |
| Feb 5, 2008 | 38181299X | RESOLVE | Hazardous | 14M07,24X10,21L10,69J10,69D10,84T07,84D06.14M-SECOND OFF.24X-BSMNT.21L-PULLING BSMT HATCH DOOR STOPS CAR IN FLIGHT.69... | $1,000 | $0 | Mar 31, 2008 |
| Feb 5, 2008 | 38181750L | RESOLVE | Non-Hazardous | 24X10,66O02,66Y02,55Y10,55B07,84D06,36T07,36D06.24X-BSMT.66O,Y-CLEAN &REMOVE LARGE QUANTITY OF MACHINE OIL FROM PIT.5... | $0 | $0 | Mar 31, 2008 |
| Oct 15, 2007 | 38178937Y | RESOLVE | Non-Hazardous | 14M07,59X10,84S10,66K10,85BB05,86BB05.84S-UNPROTECTED WOOD OVERHEAD ROOF.66K-PIT STEEL. | $350 | $0 | Jun 2, 2008 |
| Nov 8, 1997 | 38063309N | RESOLVE | Non-Hazardous | 13M14M35P57Z57O | $350 | $0 | Nov 23, 1998 |
| May 26, 1993 | 38033395L | RESOLVE | Non-Hazardous | 73H 57O 73 X/WEIGHTS LANDING ON SPRING PROVIDE PROPER RUN BY 57 WATER IN PIT | $0 | $0 | Nov 1, 1993 |
| May 26, 1993 | 38033396N | RESOLVE | Non-Hazardous | 73H 57O 73 C/WEIGHTS LANDING ON SPRING PROVIDE PROPER RUN BY | $0 | $0 | Nov 1, 1993 |
| Jan 18, 1991 | 38003979H | RESOLVE | Non-Hazardous | 03R,10R,15R,18R,37R. ITEMS (03),(10),(15),(18) & (37) INSTALLED NEW WITHOUT A PERMIT. | $0 | $0 | Oct 7, 1991 |
| Jan 18, 1991 | 38003980P | RESOLVE | Non-Hazardous | 03R,10R,15R,18R,37R. | $0 | $0 | Oct 7, 1991 |
| Aug 8, 1988 | 34010820X | RESOLVE | Non-Hazardous | WORK WIHTOUT A PERMIT. REFRIGERATION UNIT ERECTED IN ADJACANT ALLEY AT SOUTH WEST CORNER OF PREMISES. REMEDY: OBTAIN ... | $0 | $0 | Nov 28, 1988 |