ECB violations
31-26 Northern Boulevard, Queens • Block 00239 • Lot 0111
26 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Jun 18, 2024 | 39529770J | RESOLVE | CLASS - 2 | AT TIME OF INSPECTION OBSERVED NB 12 THE SERVICE ELEVATOR IS OUT OF OPERATION CREATE AN UNSAFE CONDITION FOR FDNY-BC ... | $2,500 | $0 | Aug 27, 2024 |
| Mar 11, 2024 | 39526313K | RESOLVE | CLASS - 1 | YODOCK.@12STORY NB SITE IN RESPONSE INCIDENT OF BARRIER COLLAPSED ONTO PEDESTRIAN&TAKEN TO MEDICAL FACILITY BY FDNY, ... | $6,250 | $0 | Sep 24, 2024 |
| Feb 20, 2024 | 39525724K | RESOLVE | CLASS - 2 | AT THE TIME OF MY INSPECTION I OBSERVED OUTRIGGER BEAM SCAFFOLD IN USE INSTALLED CONTRARY TO PLANS-TIEBACK GOING IN A... | $625 | $0 | Apr 30, 2024 |
| Nov 2, 2023 | 39523164M | RESOLVE | CLASS - 2 | INCIDENT OCCURRED ON NOVEMBER 2, 2023 WHEN A FORKLIFT BACKED INTO A PARKED CAR THAT WAS IN THE DRIVEWAY/ACCESS POINT ... | $5,000 | $0 | Mar 12, 2024 |
| Jun 26, 2023 | 39518293M | RESOLVE | CLASS - 2 | AT THE TIME OF MY INSPECTION I OBSERVED STREET SIGN OBSTRUCTED BY FENCE (STOP SIGN LOCATED BEHIND CONSTRUCTION FENCE ... | $0 | $0 | Sep 5, 2023 |
| Jun 26, 2023 | 39518289J | RESOLVE | CLASS - 1 | AT THE TIME OF MY INSPECTION OF EXCAVATION I OBSERVED WORK CONTRARY TO PLANS-PILES NOT INSTALLED TO GRADE AS ON PLANS... | $625 | $0 | Feb 1, 2024 |
| May 5, 2023 | 39516183M | RESOLVE | CLASS - 2 | AT THE TIME OF MY INSPECTION OBSERVED SIDEWALK SHED AT EXP#1,4 INSTALLED CONTRARY TO PLANS-MISSING BRACING FROM POST ... | $0 | $0 | Jul 11, 2023 |
| Sep 26, 2022 | 39506853N | RESOLVE | CLASS - 1 | FAIL TO HAVE CONCRETE SAFETY MANAGER PRESENT AT SITE AS REQUIRED BC3310.9.1.@12 STORY NB SITE OBSERVE ACTIVE FOUNDATI... | $2,500 | $0 | Oct 5, 2023 |
| Sep 26, 2022 | 39506859Y | RESOLVE | CLASS - 1 | INSUFFICIENT SITE SAFETY PLAN 28-110.1.ON 12 STORY NB SITE IN EXCAVATION+FOUNDATION PHASE I OBSERVE UNSAFE SITE AND T... | $625 | $0 | Oct 5, 2023 |
| Sep 26, 2022 | 39506852L | RESOLVE | CLASS - 2 | ON 12 STORY NB SITE IN EXCAVATION/FOUNDATION PHASE I OBSERVE EXP#2 ADJACENT PROPERTY (32-04 NORTHERN BLVD) SIDE EGRES... | $5,000 | $0 | Oct 5, 2023 |
| Sep 26, 2022 | 39506854P | RESOLVE | CLASS - 1 | FAILURE TO PROVIDE EXCAVATION ACCESSES FOR INGRESS/EGRESS BC3304.7 @ 12 STORY NB SITE IN EXCAVATION/FOUNDATION PHASE ... | $625 | $0 | Oct 5, 2023 |
| May 27, 2022 | 35652393L | RESOLVE | CLASS - 1 | BC3303.14 DRAINAGE-WATER ACCUMULATION/STANDING WATER.AT TIME OF INSPECTION OF ACTIVE JOB SITE OBSERVED FOUNDATION WAL... | $2,500 | $0 | Aug 30, 2022 |
| Sep 30, 2020 | 35537758L | RESOLVE | CLASS - 2 | WRK W/O PERMIT(CONSTRUCTION FENCE PERMIT EXPIRED)AS NOTED:AT TIME OF INSPECTION FOR A CONSTRUCTION JOB SITE WAS CLOSE... | $625 | $0 | Dec 22, 2020 |
| Aug 18, 2018 | 35345148H | RESOLVE | CLASS - 1 | BC3303.13.1.FENCING AT TIME OF INSPECTION OBSERVED NONE ACTIVE JOB SITE.THE JOB SITE FENCE HAS NOT MAINTAINED AT EXPO... | $2,530 | $0 | Mar 19, 2019 |
| Jul 14, 2018 | 35345128K | RESOLVE | CLASS - 2 | FENCE AT TIME OF INSPECTION NONE ACTIVE JOB SITE. THE JOB SITE FENCE WASD NOT MAINTAIN EXP#3 FENCE FALLING SOME PANEL... | $800 | $0 | Jan 29, 2019 |
| Sep 19, 2014 | 36019772Y | RESOLVE | CLASS - 2 | FAILURE TO FILE AN ACCEPTABLE CYCLE 7 TECHNICAL REPORT IN COMPLIANCE WCODE PROVISIONS : PERIODIC INSP. OF EXTERIOR WA... | $0 | $0 | Nov 27, 2015 |
| Aug 28, 2014 | 34982171L | RESOLVE | CLASS - 2 | WORK DOES NOT CONFORM TO APPROVED SOE DOC.@ TIME OF INSP I OBSERV FOUNDATION WORK IN PROGRESS,NON-COFORMING TO APPROV... | $500 | $0 | Oct 14, 2014 |
| Aug 28, 2014 | 34982174R | RESOLVE | CLASS - 2 | BC 3304.4.4 & 27-10326 FAIL TO PROVIDE 3'& 6"OR SOLID ENCLOSURE AROUNDOPEN SIDES OF EXCAVATION.GUARDRAIL @ TIME OF IN... | $800 | $0 | Oct 14, 2014 |
| Aug 28, 2014 | 34982172N | RESOLVE | CLASS - 2 | 28-105 128 & 27-2018 WORK DOES NOT CONFORM TO APPROVED SITE SAFETY PLAN.@ TIME OF INSP I OBSERV FOUNDATION WORK IN PR... | $800 | $0 | Oct 14, 2014 |
| Jul 31, 2014 | 35025659R | RESOLVE | CLASS - 1 | NEW BLDG OR OPEN LOT OCCUP W/O A VALID C OF O.THE BLDG IS OCCUP AS A PUBLIC STORAGE BUSINESS & A CARETAKERS APT.THE C... | $2,500 | -$2,500 | Sep 23, 2014 |
| Jul 31, 2014 | 35098668X | RESOLVE | CLASS - 2 | ELECT WORK W/O A PERMIT.NOTE:OBSERV ACTIVE CONST SITE @ 31-38 NORTHERNBLVD IS RECURRING"TEMP"POWER FROM 33-04 NORTHER... | $400 | $0 | Feb 10, 2015 |
| Jul 31, 2014 | 35098670P | RESOLVE | CLASS - 2 | JOB SITE FENCE NOT CONSTRUCTED PURSUANT TO SUBSECTION.@ TIME OF INSP OBSERV A SECTION OF FENCE APPROX 280 LINEDR FEET... | $400 | $0 | Feb 10, 2015 |
| Jul 31, 2014 | 35098671R | RESOLVE | CLASS - 1 | 3313 FAIL TO COMPLY W/NYC FIRE CODE.UPON REQUEST NO PERMIT FOR OXYGEN & ACETYLENE WAS PRESENTED @ SITE .OBSERV WORKER... | $1,600 | $0 | Feb 10, 2015 |
| Jul 31, 2014 | 35098667Y | RESOLVE | CLASS - 1 | FAILURE TO HAVE SITE COORDINATOR PRESENT AS REQUIRED.@ TIME OF INSP OBSERV @ SITE WELDING OF PILES FORM WORK & EXCAVA... | $2,400 | $0 | Feb 10, 2015 |
| Nov 21, 2008 | 36001090L | RESOLVE | CLASS - 2 | FAILURE TO SUBMIT AN ACCEPTABLE SIXTH ROUND TECHNICAL REPORT IN COMPLIANCE W/ CODE PROVISIONS:PERIODIC INSPECTION OF ... | $4,000 | $0 | Jul 14, 2009 |
| Jul 25, 2008 | 34693748X | RESOLVE | CLASS - 3 | WORK DOES NOT CONFORM TO APPROVED CONSTRUCTION DOCUMENTS OR AMENDMENTSBASED ON EXTENT OF WORK PROGRESS SIGNIFICANT CH... | $500 | $0 | Mar 17, 2009 |