Job filings
29-30-29-50 Borden Avenue, Queens • Block 00295 • Lot 0035
16 records
Work filed with the Department of Buildings under its legacy BIS system.
| Latest action | Job | Type | Status | Work | Cost | Owner |
|---|---|---|---|---|---|---|
| Oct 31, 2018 | 440432426 | Alteration Type II | PERMIT ISSUED - ENTIRE JOB/WORK | INSTALLATION OF GAS PIPING AND UNIT HEATERS FOR THE 1ST FLOOR LEVEL ONLY. | $15,000 | THE BORDEN REVIEW LLC |
| Aug 14, 2018 | 421664363 | Alteration Type II | PERMIT ISSUED - ENTIRE JOB/WORK | IN EXISTING COMMERCIAL SPACE 1 FL- NEW BATHROOM, INSTALLATION OF TRENCH DRAINS, INSTALLATION OF ROLLING GATES WITH MI... | $48,500 | THE BORDEN REVIEW LLC |
| Dec 14, 2017 | 420656917 | Alteration Type I | PERMIT ISSUED - PARTIAL JOB | — | $400,000 | THE BORDEN REVIEW LLC |
| Oct 30, 2017 | 421558264 | Alteration Type II | PERMIT ISSUED - ENTIRE JOB/WORK | PROPOSED FOUNDATION PLAN IN CONJUNCTION WITH ALT 1 JOB #420656917 | $150,000 | THE BORDEN REVIEW LLC |
| Jun 28, 2017 | 421520571 | Subdivision Condominiums | PLAN EXAM - IN PROCESS | LOT NO. 35 TENTATIVE LOT NOS. 1001-1002. SEE COMMENTS FOR DETAILS. | $0 | COMPLETE CONDO SERVICES |
| Mar 29, 2016 | 421228488 | Alteration Type II | SIGNED OFF | FILING HEREWITH MECHANICAL PLANS FOR TEMPORARY TRAILERS. SPECIFICALLY TO CAPTURE HVAC UNITS INSTALLED AT EACH TEMPORA... | $3,000 | THE BORDEN REVIEW LLC |
| Feb 9, 2016 | 421149466 | Alteration Type I | PLAN EXAM - DISAPPROVED | STRUCTURAL PLAN IN CONJUNCTION WITH ALT 1 APPLICATION JOB NO: 421149466. | $0 | THE BORDEN REVIEW LLC |
| Feb 4, 2016 | 421246299 | Alteration Type II | PERMIT ISSUED - ENTIRE JOB/WORK | FILING HEREWITH FOR THE REMOVAL AND INSTALLATION OF INTERIOR NON LOAD BEARING PARTITIONS AND RELATED FINISHES AS PER ... | $325,256 | THE BORDEN REVIEW LLC |
| Feb 3, 2016 | 421246306 | Alteration Type II | PERMIT ISSUED - ENTIRE JOB/WORK | FILING HEREWITH FOR MODIFICATIONS TO EXISTING SPRINKLER SYSTEM AS PER PLANS. NO CHANGE IN USE, EGRESS OR OCCUPANCY UN... | $33,000 | THE BORDEN REVIEW LLC |
| Jan 13, 2016 | 440281384 | Alteration Type III | PERMIT ISSUED - ENTIRE JOB/WORK | PROPOSED INSTALLATION OF HEAVY DUTY SIDEWALK SHED FILED FOR REMEDIAL REPAIRS AS PER PLANS. NO CHANGE IN USE OCCUPANCY... | $0 | HKS CONSTRUCTION CORP |
| Jan 7, 2016 | 421246618 | Alteration Type II | PLAN EXAM - DISAPPROVED | FILING HEREWITH FOR THE INSTALLATION OF A NEW AUTOMATIC SMOKE/HEAT DETECTION AND SPRINKLER FIRE ALARM SYSTEM AS PER P... | $45,000 | THE BORDEN REVIEW LLC |
| Jan 7, 2016 | 421247671 | Alteration Type II | PLAN EXAM - DISAPPROVED | FILING HEREWITH FOR DETECTION GAS MONITORING (CO2) FIRE ALARM SYSTEM/DEVICES PANEL/SYSTEM TIED INTO BASE BUILDING FAC... | $15,000 | THE BORDEN REVIEW LLC |
| Jan 4, 2016 | 421238850 | Alteration Type II | PERMIT ISSUED - ENTIRE JOB/WORK | INTERIOR STRUCTURAL REINFORCEMENT OF EXISTING BEAMS AND COLUMNS. MINOR CONCRETE REMOVAL TO BE DONE IN CONNECTION WITH... | $50,000 | THE BORDEN REVIEW LLC |
| Dec 16, 2015 | 440276595 | Alteration Type II | PLAN EXAM - IN PROCESS | MODIFICATION OF EXISTING SPRINKLER/STANDPIPE SYSTEM FOR THE ENTIRE BUILDING IN CONJUNCTION WITH ALT 1 APPLICATION # 4... | $95,000 | THE BORDEN REVIEW LLC |
| Jul 9, 2015 | 421183542 | Alteration Type III | PLAN EXAM - DISAPPROVED | BPP FILING IN CONJUNCTION WITH ALT 1 APPLICATION, JOB NO:421149466. STREET FRONTAGE 100' | $0 | THE BORDEN REVIEW LLC |
| Mar 4, 2004 | 401826618 | Alteration Type II | SIGNED OFF | Installation of rooftop AC unit. over existing steel beams. No change in use egress or occupancy. | $10,000 | Price king inc |