ECB violations
28-02-28-10 38 Avenue, Queens • Block 00385 • Lot 0009
17 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Sep 27, 2024 | 37029368H | RESOLVE | CLASS - 2 | FAILURE TO FILE REQUIRED ANNUAL BOILER INSPECTION REPORTS FOR LOW-PRESSURE BOILER 40000160674N0001 IN ACCORDANCE WITH... | $0 | $0 | Jun 3, 2025 |
| Dec 26, 2023 | 39524318K | RESOLVE | CLASS - 2 | BC 3307.4.7- WORK OR STORAGE ZONES. OBSVD A STORAGE ZONE IN THE ROADWAY AT EXP#1 WITH 7 PALLETS OF BRICK STORED & A S... | $2,500 | $0 | Aug 2, 2024 |
| Dec 26, 2023 | 39524316R | RESOLVE | CLASS - 2 | OBSVD SUP SCAF AT EXP#1 WITH EXP#1 FOOTING AT SWS/2FT FRAME CONNECTION PLACED ON ADDITIONAL BEAM PLACED PARALLEL TO S... | $625 | $0 | Aug 2, 2024 |
| Dec 26, 2023 | 39524317Z | RESOLVE | CLASS - 2 | PROTECTION OF ADJ PROP- BC 3309.1. OBSVD 2FL SETBACK WITH UNFINISHED PARAPET WALL, WITH THE EXP#2 ADJ PROP (38-10 29T... | $625 | $0 | Aug 2, 2024 |
| Nov 9, 2023 | 35675172J | RESOLVE | CLASS - 2 | BC 3301.7 FAILURE TO PROVIDE MEANS AND METHOD BY P.E FOR CONCRETE REPAIR. AS NOTED: AT TIME OF INSPECTION AT AN ACTIV... | $0 | $0 | Jun 25, 2024 |
| Nov 9, 2023 | 35675171H | RESOLVE | CLASS - 1 | FAILURE TO INSTITUTE/MAINTAIN SAFETY EQUIPMENT MEASURES OR TEMPORARY CONSTRUCTION AND GUARDRAILS. AS NOTED: AT TIME O... | $5,000 | $0 | Jun 25, 2024 |
| Nov 9, 2023 | 35675170X | RESOLVE | CLASS - 1 | BC 3305.3.6.1.2 FAILURE TO SECURE RE-SHORES IN PROXIMITY TO UNENCLOSED PERIMETERS AS NOTED: AT TIME OF INSPECTION ON ... | $0 | $0 | Jun 25, 2024 |
| Sep 22, 2023 | 35674487J | RESOLVE | CLASS - 2 | CONDITION OF NEW BUILDINGS PERMIT.AS NOTED:AT TIME OF INSPECTION ON ACTIVE CONSTRUCTION SITE OBSERVED UNDER NEW BUILD... | $0 | $0 | Nov 28, 2023 |
| Sep 22, 2023 | 35674488L | RESOLVE | CLASS - 1 | FAILURE TO PROVIDE MASONRY CMU BLOCK WALL CONSTRUCTION BRACING ACCODANCE WITH TMS 602/4CI 530.1/ ASCE6 SECTION.AS NOT... | $625 | $0 | Nov 28, 2023 |
| Sep 11, 2023 | 39521548M | RESOLVE | CLASS - 2 | UPON INSPECTION OF AN ACTIVE CONSTRUCTION SITE I OBSERVED A SIDEWALK SHED INSTALLED AT EXPOSURE 1&4 CONTRARY TO APPRO... | $0 | $0 | Nov 21, 2023 |
| Sep 11, 2023 | 39521551N | RESOLVE | CLASS - 2 | I OBSERVED WORK CONTRARY TO THE SITE SAFETY PLAN. AS PER SSP A 4 FOOT FENCE WITH WIRE MESH ON TOP SHOULD BE INSTALLED... | $0 | $0 | Nov 21, 2023 |
| Jul 27, 2023 | 39519843M | RESOLVE | CLASS - 2 | AT TIME OF INSPECTION FOR CLASS1 VIO#39517356X , UNABLE TO VERIFY CORRECTION OF VIOLATING CONDITION, UPON REVIEWING D... | $625 | $0 | Oct 3, 2023 |
| Jun 2, 2023 | 39517356X | RESOLVE | CLASS - 1 | OBSERVED WORKERS PERFORMING CONCRETE OPERATIONS, UPON REVIEW THE PRESHIFT MEETING, OBSERVED PRE-SHIFT MEETING DID NOT... | $0 | $0 | Sep 5, 2023 |
| Jun 2, 2023 | 39517355Y | RESOLVE | CLASS - 2 | OBSERVED WORKERS POURING CONCRETE WITH CONCRETE PUMP OVER PUBLIC SIDEWALK WITH NO PROTECTION FOR PEDESTRIAN, SIDEWALK... | $2,400 | $0 | Sep 5, 2023 |
| Sep 28, 2019 | 35449744K | RESOLVE | CLASS - 2 | 3301.2 FAILURE TO PROVIDE SAFETY MEASURES.AT THE TIME OF MY INSPECTIONTO RESPOND A COMPLAINT OBSERVED DEMOLITION COMP... | $0 | $0 | Dec 10, 2019 |
| Jun 30, 2010 | 32069012L | RESOLVE | CLASS - 3 | 15,50,50A-C.(50)SEAL AROUND OIL BURNER BLAST TUBE TO BOILER CHAMBER.(50A)RESEAL FRONT BOILER CHAMBER DOOR W/ NEW GASK... | $500 | $0 | Aug 23, 2011 |
| May 9, 1994 | 34109440Y | RESOLVE | Hazardous | EXIT PASSAGE TOTAL OBSTRUCTION. FIRE EXIT PASSAGE WAY ON 38-09 28ST PROPERTY FOR USE IN FIRE EMERGENCY FOR 38-10 29 S... | $475 | $0 | Jul 19, 1994 |