Issued Violation Status Severity Description Penalty Balance due Hearing
Dec 14, 2020 39033408H RESOLVE CLASS - 1 PHONE NOT WORKING REPAIR EMERGENCY ESCAPE HATCH UNSECURED PROVIDE $312 $0 Mar 30, 2021
Dec 14, 2020 39033441J RESOLVE CLASS - 2 PHONE NOT WORKING REPAIR ESCAPE HATCH NOT SECURE PROPERLY SECURE $312 $0 Mar 30, 2021
Nov 15, 2019 37016881X RESOLVE CLASS - 2 AC279291-FAILURE TO COMPLETE THE INSTALLATION OF A FULL SYSTEM OF AUTOMATIC SPRINKLERS AND FILE A FINAL SPRINKLER REP... $0 $0 Jun 9, 2020
Mar 9, 2016 38241454Z RESOLVE CLASS - 2 67X10,57M07. 67X10-REPAIR EMERGENCY PHONE; 57M07-PROVIDE FIRE EXTINGUISHER IN MOTOR ROOM. $0 $0 Apr 26, 2016
Feb 26, 2016 35174118N RESOLVE CLASS - 2 REMOVAL OF SIDEWAQLK SHED W/O DEPT'S APPROVAL. NOTE: AT THE TIME OF INSPECTION, BLDG FACADE WERE STILL DESIGNATED AS ... $800 $0 Jul 26, 2016
May 11, 2015 35130700Y RESOLVE CLASS - 1 3307.5.2 FLAG PERSONS:NOT PROVIDED. AT TIME OF INSPECTION OBSERVED ACTIVE JOBSITE. AT EXP#1 ALONG CRESCENT ST OBSERVE... $1,600 $0 Dec 8, 2015
May 11, 2015 35130701X RESOLVE CLASS - 2 FAILURE TO MAINTAIN HOUSEKEEPING. AT TIME OF INSPECTION OBSERVED ACTIVE JOBSITE AT THE 10TH FLR OBSERVED DEBRIS SCATT... $400 $0 Dec 8, 2015
Feb 6, 2015 35150588L RESOLVE CLASS - 1 3314.13.2 PARTIAL STOP WORK ORDER FOR SUPPORTED SCAFFOLD ISUSED PURSUANT TO 28-207.2 AND POSTED AT PREMISES SCAFFOLD ... $1,600 $0 Mar 24, 2015
Feb 6, 2015 35150587J RESOLVE CLASS - 1 3314.5 PARTIAL STOP WORK ORDER FOR SUPPORTED SCAFFOLD ISSUED PURSUANT TO 28-207.2 AND POSTED AT PREMISES SCAFFOLD IN ... $1,600 $0 Mar 24, 2015
Feb 6, 2015 35150586H RESOLVE CLASS - 1 PARTIAL STOP WORK ORDER FOR SUPPORTED SCAFFOLD ISSUED PURSUANT TO 28-207.2 AND POSTED AT PREMISES SCAFFOLD IN UNSAFE ... $1,600 $0 Mar 24, 2015
Jan 26, 2015 36027234R RESOLVE CLASS - 2 FAILURE TO FILE AN ACCEPTABLE CYCLE 7 TECHNICAL REPORT IN COMPLIANCE WITH CODE PROVISIONS: PERIODIC INSPECTION OF EXT... $400 $0 Aug 25, 2015
Oct 23, 2014 35110209X RESOLVE CLASS - 1 WORK DOES NOT CONFORM TO APPROVED CONSTRUCTION DOCUMENTS;PIPE SCAFFOLDAT TIME OF INSPECTION OBSERVED PIPE SCAFFOLD ER... $1,030 $0 Mar 17, 2015
Oct 23, 2014 35110210N RESOLVE CLASS - 1 3303.3 OBSTRUCTION OF SIDEWALK AND STREET W/O DOT PERMIT. AT TIME OF INSPECTION OBSERVED ACTIVE JOBSITE.PEDESTRIAN SI... $0 $0 Dec 9, 2014
Oct 23, 2014 35110208Y RESOLVE CLASS - 1 3308.1.2 HORIZONTAL NETTING REQUIRED DURING ALTERATIONS.AT TIME OF INSPECTION OBSERVED ACTIVE JOBSITE.PARAPET BRICK H... $1,600 $0 Dec 9, 2014
Oct 23, 2014 35110206K RESOLVE CLASS - 1 FAILURE TO PERFORM SUCCESSFUL HYDROSTATIC PRESSURE TEST OF STANDPIPE SYSTEMS. AT TIME OF INSPECTION OBSERVED 9STORY B... $2,400 $0 Dec 9, 2014
Oct 23, 2014 35110207M RESOLVE CLASS - 1 FAILURE TO INSTITUTE/MAINTAIN SAFETY EQUIPMENT; GUARDRAILS.AT TIME OF INSPECTION OBSERVED ACTIVE JOBSITE.GUARDRAILS M... $1,200 $0 Dec 9, 2014
Sep 12, 2013 35021594R RESOLVE CLASS - 1 SEC. EC 250.4. NON-CARRYING ELECTRICAL CONDUCTIVE MATERIAL IS NOT GROUNDED. SIDEWALK SHED IS METAL AND COULD BE ENERG... $1,600 $0 Jan 7, 2014
Sep 12, 2013 35021595Z RESOLVE CLASS - 1 UNAPPROVED UNSAFE UNSUITABLE ELECTRICAL EQUIPMENT APPARATUS MATERIALS DEVICES APPLIANCES OR WIRING IN USE. FIXTURE BO... $1,600 $0 Jan 7, 2014
Sep 11, 2013 35010426Y RESOLVE CLASS - 2 FAILURE TO PROVIDE APPROVED/ACCEPTED PLANS AT JOB STIE AT TIME OF INSPECTION. NOTES: SIDEWALK SHED HAS BEEN ERECTED A... $0 $0 Oct 29, 2013
Sep 11, 2013 35010424K RESOLVE CLASS - 2 WORK DOES NOT CONFORM TO APPROVED CONSTRUCTION DOCUMENTS AND/OR APPROVED AMENDMENTS. NOTES: SIDEWALK SHED HAS BEEN ER... $0 $0 Oct 29, 2013
Apr 1, 2011 34907602Y RESOLVE CLASS - 3 FAILURE TO MAINTAIN BLDG WALLS OR APPURTENANCES. NOTED: THE ROOF AND CONCRETE CEILING AT 7TH FLR ROOM 711 HAS BECOME ... $250 $0 May 17, 2011
May 5, 2010 34848033X RESOLVE CLASS - 2 FAILURE TO MAINTAIN. OBSERVED: AT FLRS 3 & 7 OF SCHOOL, BOWED, MISSINGCEILING TILES, EXPOSING ELECTRICAL WIRES ABOVE.... $0 $0 Jul 20, 2010
Mar 28, 2008 34684079N RESOLVE Non-Hazardous FAILURE TO FILE AN AMENDED SIXTH ROUND REPORT ACCEPTABLE TO THIS DEPARTMENT INDICATING CORRECTION OF UNSAFE CONDITION... $700 $0 Jan 27, 2009
Mar 4, 2008 34418731N RESOLVE Hazardous SEC. 27-129(D)(I)(A). LOCAL LAW REPORT FILED AS "UNSAFE" UNSAFE CONDITION EXISTED & NO MEASURES TAKEN TO SECURE SAFET... $800 $0 Apr 29, 2008
Feb 23, 2007 34561911M RESOLVE Non-Hazardous FAILURE TO MAINTAIN EXTERIOR WALL DEFECTS/NOTED:AT WEST EXPOSURE-PRECAST CONCRETE TRIM PANELS ARE CRACKED,SPALLED & O... $350 $0 Apr 24, 2007
Jan 26, 2007 38163858Y RESOLVE Non-Hazardous 55Y02,55Y13,55A09,60Q03,84D06,66O02,71Q03,71L11,33Q02,33A06,83A01.83A01-CAR HITS ROLLERS ON 3 & 6FL.55A09-REMOVE UNUS... $180 $0 Mar 27, 2007
Jan 26, 2007 38163859X RESOLVE Non-Hazardous 38O02,84L11,16B01,71Q03.84L11-CAR DOOR CLUTCH,16B01-LOBBY DOOR DOESN'TCLOSE WHILE BLDG DOOR IS OPEN,71Q03-INSTALL MIS... $180 $0 Mar 27, 2007
Jan 4, 2003 34376115R RESOLVE Non-Hazardous ALTERED BUILDING OCCUPIED W/O A VALID C/O ALT TYPE 1 CO # 401452566 EXPRED ON 11-11-02 REMEDY : OBTIAN A VALID C/O $180 $0 Feb 18, 2003
Feb 20, 2001 34279347L RESOLVE Non-Hazardous FAILURE TO MAINTAIN DEFECTS ARE:CRACKED CONCRETE CEILINGS LOCATIONS:514,513,512 REMEDY DO REPAIRS, $0 $0 Apr 24, 2001
Jul 21, 1998 38076730J RESOLVE Non-Hazardous 46,K,02,57,0,02,58,0,02,59,0,02,35,0,02,50,0,02 46-HOIST CABLES 02-ALARM SYSTEM 57-PIT 58-CAR GUIDE-RAILS &7 BRACKETS... $0 $0 Sep 8, 1998
Jul 21, 1998 38076731L RESOLVE Non-Hazardous 73,0,02,46,0,02, 73-ENTIRE DEVICE 02-ALARM SYSTEM 46-HOIST CABLES $0 $0 Sep 8, 1998
Feb 24, 1993 34079224P RESOLVE Hazardous FAILURE TO FILE AN AMENDED REPORT ACCEPTABLE TO THIS DEPARTMENT PURSUANT TO RULE R.C.N.Y. 32-031B(5) INDICATING CORRE... $1,000 $0 Apr 13, 1993
Oct 20, 1992 34079040K RESOLVE Hazardous FAILURE TO FILE AN AMENDED REPORT AC CEPTABLE TO THIS DEPARTMENT PURSUANT TO RULE RCNY 32-03B(5)INDICATING CORRECTION... $1,000 $0 Dec 1, 1992
Aug 5, 1992 34057624R RESOLVE Hazardous FAILURE TO FILE AN AMENDED REPORT ACCEPTABLE TO THIS DEPARTMENT PURSUANT TO RULE R.C.N.Y. 32-03B(5) INDICATING CORREC... $400 $0 Oct 20, 1992
Sep 27, 1991 38015138L RESOLVE Non-Hazardous 46J,21L,57O,03M,37L #(21) IN CAR. #(03) ELECTRICAL BOX COVERS ON TOP OF CAR # (37) ELIMINATE EXCESSIVE NOISE FROM CON... $0 $0 Nov 12, 1991
Jan 30, 1991 38004350P RESOLVE Non-Hazardous 4# PROVIDE KEY $1,000 $0 May 28, 1991
Sep 28, 1990 38001431N RESOLVE Non-Hazardous 16L,4H,4)PROVIDE KEY $75 $0 Nov 13, 1990
Sep 28, 1990 38001433R RESOLVE Hazardous 4#,18J,22M,28L,4)PROVIDE KEY. 18)PROPERLY ALIGN LOCK ROLLERS WITH CLUTCH. 22)CEASE USE DUE TO MISSING DOOR. $0 $0 Nov 13, 1990
Sep 28, 1990 38001432P RESOLVE Non-Hazardous 4#,7X,4)PROVIDE KEY $75 $0 Nov 13, 1990