11-02-11-12 30 Drive, Queens • Block 00504 • Lot 0122
18 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| May 29, 2026 | 39190362K | ACTIVE | CLASS - 1 | FAILURE TO PROVIDE UNOBSTRUCTED EXIT PASSAGEWAY. AT TIME OF INSPECTION AT 1ST FLOOR HALLWAY & CORRIDOR 3 DOORS TO EXI... | $2,500 | $2,500 | Feb 5, 2027 |
| May 29, 2026 | 39190363M | ACTIVE | CLASS - 2 | FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER: USE OF PROHIBITED DOOR AND/OR HARDWARE PER BC 1008.1.8 (2014 C... | $1,250 | $1,250 | Feb 5, 2027 |
| Feb 7, 2023 | 35666416M | RESOLVE | CLASS - 2 | PERMANENT DWELLING USED/CONVERTED FOR OTHER THAN PERMANENT-RESIDENTIAL PURPOSES C/O #4623158 INDICATES PREMISES TO BE... | $2,500 | $0 | Sep 12, 2023 |
| Feb 7, 2023 | 35666417Y | RESOLVE | CLASS - 2 | BC907.2.8 FAILURE TO PROVIDE CLASS "J" FIRE ALARM SYSTEM FOR TRANSIENT USE AT UNIT 618W(6TH FL)REMEDY:DISCONTINUE ILL... | $1,250 | $0 | Sep 12, 2023 |
| Mar 27, 2022 | 39058967P | RESOLVE | CLASS - 2 | I OBSERVED AN EQUIPMENT STORAGE AREA ALONG VERNON BOULEVARD WITH STEEL, AND OTHER CONSTRUCTION MATERIALS OPEN TO THE ... | $2,400 | $0 | May 17, 2022 |
| Jun 11, 2021 | 35547590X | RESOLVE | CLASS - 1 | FAILURE TO COMMUNICATE REQUIRED INFORMATION TO WORKER DURING PRE-SHIFTSAFETY MEETING. AT THE TIME OF MY INSPECTION PR... | $5,000 | $0 | Aug 31, 2021 |
| Jun 11, 2021 | 35547594N | RESOLVE | CLASS - 2 | SEC. BC 3301.13.13 FAILURE TO HAVE OR MAINTAIN THE REQUIRED DAILY LOG.NOTE: AT THE TIME OF MY INSPECTION,I OBSERVED A... | $1,250 | $0 | Aug 31, 2021 |
| May 14, 2021 | 35559362M | RESOLVE | CLASS - 1 | FAILURE TO NOTIFY DEPT OF ACCIDENT/INCIDENT THAT RESULTED IN FATALITY OR INJURY.NOTE:WORKER GOT PINNED BETWEEN A SCIS... | $2,500 | $0 | Oct 26, 2021 |
| Apr 30, 2021 | 35558580X | RESOLVE | CLASS - 2 | 3308.5 GUARD RAIL NETING.NOTE:AT THE TIME OF MY INSPECTION OF AN ACTIVE 8 STORY NB JOBSITE,I OBSERVED MISSING GUARD R... | $1,280 | $0 | Jul 20, 2021 |
| Apr 30, 2021 | 35558581H | RESOLVE | CLASS - 2 | INADEQUATE SCAFFOLD SYSTEM.AT THE TIME OF MY INSPECTION OF AN ACTIVE 8STORY NB JOBSITE AT ROOF LEVEL,I OBSERVED SET U... | $1,280 | $0 | Jul 20, 2021 |
| Apr 29, 2021 | 35558588K | RESOLVE | CLASS - 1 | A CONSTRUCTION SUPERINTENDENT FAILED TO PERFORM DUTIES AS PER RULE.THE FOLLOWING HAZARDIOUS CONDITIONS MORE OBSERVED ... | $10,030 | $0 | Aug 3, 2021 |
| Apr 29, 2021 | 35558576N | RESOLVE | CLASS - 1 | 3301.8.1 TAMPERING W/EVIDENCE.AT THE TIME OF MY RESPONSE TO AN INCIDENT WHERE A WORKER WAS PINED TO THE BACK TAIL OF ... | $2,530 | $0 | Jul 20, 2021 |
| Apr 29, 2021 | 35558587Z | RESOLVE | CLASS - 1 | FAILURE TO INSTITUTE AND MAINTAIN SAFETY EQUIPMENT MEASURES.NOTE:AT THE TIME OF MY INSPECTION RESPONDING TO A COMPLAI... | $10,030 | $0 | Aug 3, 2021 |
| Apr 29, 2021 | 35558578R | RESOLVE | CLASS - 1 | FAILURE TO PROVIDE EVIDENCE OF SCISSORS LIFT TRAINING CARD IN ACCORDANCE TO MANUFACTURORS SPECIFICTIONS.AT THE TIME O... | $2,530 | $0 | Jul 20, 2021 |
| Apr 13, 2020 | 35469347P | RESOLVE | CLASS - 1 | JOBSITE FENCE.NOTE:AT THE TIME OF MY INSPECTION,I OBSERVED THAT APPROXIMATELY 40 FEET OF THE CONSTRUCTION FENCE HAD D... | $10,000 | $0 | Nov 10, 2020 |
| Feb 6, 2020 | 35411190Y | RESOLVE | CLASS - 1 | AT TIME OF INSPECTION SUPERVISION OR USE OF POWER OPERATED HOISTING MACHINE W/O A HOISTING MACHINE OPERATORS LICENSE.... | $5,000 | $0 | Mar 2, 2021 |
| Jan 19, 2018 | 35273207Z | RESOLVE | CLASS - 2 | WORK WITHOUT A PERMIT. (CONSTRUCTION PLYWOOD FENCE PERMIT EXPIRED). AS NOTED: AT TIME OF INSPECTION CONSTRUCTION SITE... | $2,000 | $0 | Mar 6, 2018 |
| Aug 3, 2007 | 34583456R | RESOLVE | Non-Hazardous | USE OR INSTALLATION OF PLUMBING MATERIALS OR EQUIPMENT WHICH DO NOT COMPLY W/ RS-16.IN WAREHOUSE PVC PIPING INSTALLED... | $2,500 | $0 | Mar 25, 2008 |